{"id":3010,"date":"2026-08-02T15:27:43","date_gmt":"2026-08-02T15:27:43","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3010"},"modified":"2026-08-17T20:23:53","modified_gmt":"2026-08-17T12:23:53","slug":"daxin-rm33-300kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/fr\/product\/daxin-rm33-300kva-system-ups\/","title":{"rendered":"300kVA Modular Online UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 300kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large data centers, telecom facilities, industrial plants and other mission-critical power applications.<\/p>\n<p>Its modular architecture integrates scalable power modules, centralized control, protection and service access within a common UPS platform, allowing installed capacity and redundancy to be planned according to the critical load and future expansion requirements.<\/p>\n<p>The RM33-300kVA reference configuration provides 300kW cabinet capacity and supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load and external battery configurations.<\/p>\n<p>Final power-module configuration, battery autonomy, redundancy architecture, bypass, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.<\/p>\n<h2>Principaux avantages<\/h2>\n<ul>\n<li><strong>300kW Cabinet Capacity:<\/strong>\u00a0Designed for large three-phase mission-critical power systems.<\/li>\n<li><strong>Scalable Modular Architecture:<\/strong>\u00a0Power-module configuration can be planned according to current load, redundancy requirements and future expansion.<\/li>\n<li><strong>Three-Phase Online Power Protection:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/li>\n<li><strong>High Input Power Factor:<\/strong>\u00a0Input power factor is specified at \u22650.99 at full load and \u22650.98 at 50% load.<\/li>\n<li><strong>External Battery Architecture:<\/strong>\u00a0Battery capacity and backup autonomy can be engineered according to project requirements.<\/li>\n<li><strong>Flexible Redundancy Planning:<\/strong>\u00a0Modular architecture supports system designs based on required availability and future capacity growth.<\/li>\n<li><strong>Network Management:<\/strong>\u00a0Optional SNMP supports centralized UPS monitoring and power management.<\/li>\n<li><strong>Large Critical-Power Applications:<\/strong>\u00a0Suitable for data centers, telecom, industrial facilities and other high-availability infrastructure.<\/li>\n<\/ul>\n<h2>What Is a Modular UPS System?<\/h2>\n<p>A modular UPS system uses multiple power modules within a common UPS platform instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This architecture allows installed capacity, redundancy and future expansion to be planned according to the critical load and required system availability.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and optional network management for scalable critical-power applications.<\/p>\n<h2>How Should a 300kVA Modular UPS Be Sized?<\/h2>\n<p>A 300kVA modular UPS should be sized according to the actual critical load in both kW and kVA, load power factor, required redundancy, operating margin, expected future expansion and battery autonomy.<\/p>\n<p>For large data center and industrial projects, system design should also consider power-module configuration, bypass architecture, upstream and downstream protection, generator compatibility, battery capacity, communications and maintenance requirements.<\/p>\n<p>DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 modular UPS configuration.<\/p>\n<h2>Why Use a Modular UPS for Large Data Centers?<\/h2>\n<p>Modular UPS architecture allows data center operators to align installed power capacity with the actual critical load while preserving flexibility for redundancy and future expansion.<\/p>\n<p>For growing facilities, additional capacity can be planned within the supported system architecture instead of treating every future load increase as a completely separate UPS project.<\/p>\n<p>The DAXIN RM33 modular UPS platform is designed for scalable three-phase critical-power applications with external battery systems and network-management options.<\/p>\n<h2>\nDAXIN RM33-300kVA Key Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Caract\u00e9ristiques techniques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Mod\u00e8le<\/strong><\/td>\n<td><strong>RM33-300kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>UPS Type<\/td>\n<td>Modular Online UPS<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>Three-Phase Input \/ Three-Phase Output<\/td>\n<\/tr>\n<tr>\n<td>Cabinet Capacity<\/td>\n<td><strong>300kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Type de batterie<\/td>\n<td>External Battery Pack<\/td>\n<\/tr>\n<tr>\n<td>Single Battery Cabinet Capacity<\/td>\n<td>50kVA\/60kVA (50kW\/60kW)<\/td>\n<\/tr>\n<tr>\n<td>Optional Battery Cabinets<\/td>\n<td>6 \/ 5<\/td>\n<\/tr>\n<tr>\n<td>Tension d'entr\u00e9e<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Plage de tension<\/td>\n<td>110\u2013300VAC @ 50% Load; 176\u2013276VAC @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Rated Frequency<\/td>\n<td>50\/60Hz Auto-Detect<\/td>\n<\/tr>\n<tr>\n<td>Gamme de fr\u00e9quences<\/td>\n<td>40\u201370Hz<\/td>\n<\/tr>\n<tr>\n<td>Facteur de puissance d'entr\u00e9e<\/td>\n<td>\u22650.99 @ 100% Load; \u22650.98 @ 50% Load<\/td>\n<\/tr>\n<tr>\n<td>Input THDi<\/td>\n<td>&lt;4% @ 100% Load with 50kW Module<\/td>\n<\/tr>\n<tr>\n<td>Tension de sortie<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Static Voltage Stability<\/td>\n<td>\u2264\u00b11% Balanced; \u2264\u00b12% Unbalanced<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence de sortie<\/td>\n<td>50\u201360Hz<\/td>\n<\/tr>\n<tr>\n<td>Gamme de fr\u00e9quences<\/td>\n<td>46\u201354Hz or 56\u201364Hz<\/td>\n<\/tr>\n<tr>\n<td>THD de sortie<\/td>\n<td>\u22642% Linear; \u22644% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Efficacit\u00e9<\/td>\n<td><strong>95.5% with 50kW Module<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Battery Voltage<\/td>\n<td>\u00b1192V to \u00b1240V Optional<\/td>\n<\/tr>\n<tr>\n<td>Max. Charge Current<\/td>\n<td>18A Adjustable per Battery Cabinet<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><strong>1065 \u00d7 600 \u00d7 2010mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Poids net<\/td>\n<td><strong>287 \/ 297kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement<\/td>\n<td>0 \u00e0 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidit\u00e9 relative<\/td>\n<td>0\u201395%, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td>Altitude<\/td>\n<td>&lt;1000m at Rated Power<\/td>\n<\/tr>\n<tr>\n<td>Indice de protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Gestion du r\u00e9seau<\/td>\n<td>SNMP (en option)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\"><figcaption>\n<figure id=\"attachment_4953\" aria-describedby=\"caption-attachment-4953\" style=\"width: 836px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4953\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp\" alt=\"DAXIN RM33 60-600kVA Modular Online UPS Technical Specifications\" width=\"836\" height=\"1880\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp 836w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-133x300.webp 133w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-455x1024.webp 455w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-768x1727.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-683x1536.webp 683w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-5x12.webp 5w\" sizes=\"auto, (max-width: 836px) 100vw, 836px\" \/><figcaption id=\"caption-attachment-4953\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 60-600kVA three-phase modular online UPS series.<\/figcaption><\/figure>\n<p>Control Panel and Front Detail for DAXIN RM33-300kVA Modular UPS System Cabinet.<\/p>\n<\/figcaption><\/figure>\n<h2>Applications typiques<\/h2>\n<ul>\n<li>Large data centers and server facilities<\/li>\n<li>Telecom core networks and communication facilities<\/li>\n<li>Industrial automation and manufacturing plants<\/li>\n<li>Financial and banking infrastructure<\/li>\n<li>Healthcare and medical facilities<\/li>\n<li>Transportation and public infrastructure<\/li>\n<li>Enterprise IT and cloud infrastructure<\/li>\n<li>Other large mission-critical three-phase power systems<\/li>\n<\/ul>\n<h2>S\u00e9lection et planification du projet<\/h2>\n<p>Avant de passer commande, v\u00e9rifiez que la puissance nominale exacte, la phase d'entr\u00e9e\/sortie, la tension, la fr\u00e9quence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la m\u00e9thode d'installation correspondent bien au mod\u00e8le s\u00e9lectionn\u00e9 et aux plans du projet.<\/p>\n<h2>Foire aux questions<\/h2>\n<h3>Ce produit peut-il \u00eatre configur\u00e9 pour un projet sp\u00e9cifique ?<\/h3>\n<p>Oui. La configuration \u00e9lectrique, l'autonomie de la batterie, les syst\u00e8mes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent \u00eatre examin\u00e9s en fonction des exigences du site.<\/p>\n<h3>Les notes techniques sont-elles toutes communes \u00e0 l'ensemble de la s\u00e9rie ?<\/h3>\n<p>Non. Les caract\u00e9ristiques techniques et les fonctions varient selon le mod\u00e8le et la configuration. Veuillez vous r\u00e9f\u00e9rer \u00e0 la fiche technique sp\u00e9cifique au projet comme r\u00e9f\u00e9rence d\u00e9finitive.<\/p>\n<h3>DAXIN ENERGY peut-elle vous aider \u00e0 choisir un syst\u00e8me ?<\/h3>\n<p>Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la dur\u00e9e de fonctionnement requise, l'objectif de redondance, les exigences en mati\u00e8re de communication et l'environnement d'installation.<\/p>\n<h3>Demander une configuration de projet<\/h3>\n<p>Envoyez-nous les donn\u00e9es de charge, le sch\u00e9ma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.<\/p>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"9315\" data-end=\"9473\"><strong data-start=\"9315\" data-end=\"9349\">What is the DAXIN RM33 300kVA?<\/strong><br data-start=\"9349\" data-end=\"9352\" \/>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large scalable critical-power applications.<\/p>\n<p data-start=\"9475\" data-end=\"9584\"><strong data-start=\"9475\" data-end=\"9508\">What is the cabinet capacity?<\/strong><br data-start=\"9508\" data-end=\"9511\" \/>The RM33-300kVA reference configuration specifies 300kW cabinet capacity.<\/p>\n<p data-start=\"9586\" data-end=\"9721\"><strong data-start=\"9586\" data-end=\"9636\">What input and output voltage does it support?<\/strong><br data-start=\"9636\" data-end=\"9639\" \/>The reference specification lists 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/p>\n<p data-start=\"9723\" data-end=\"9867\"><strong data-start=\"9723\" data-end=\"9758\">What is the input power factor?<\/strong><br data-start=\"9758\" data-end=\"9761\" \/>The specification lists an input power factor of at least 0.99 at 100% load and at least 0.98 at 50% load.<\/p>\n<p data-start=\"9869\" data-end=\"10062\"><strong data-start=\"9869\" data-end=\"9914\">Does the RM33 support external batteries?<\/strong><br data-start=\"9914\" data-end=\"9917\" \/>Yes. The RM33-300kVA uses an external battery architecture, with final battery capacity and runtime engineered according to project requirements.<\/p>\n<p data-start=\"10064\" data-end=\"10216\"><strong data-start=\"10064\" data-end=\"10114\">Can the RM33-300kVA support remote monitoring?<\/strong><br data-start=\"10114\" data-end=\"10117\" \/>Yes. Optional SNMP network management is available for centralized power monitoring and management.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. With 300kW cabinet capacity, 380\/400\/415VAC three-phase operation, external battery configurations and optional SNMP monitoring, it supports large mission-critical power systems requiring flexible capacity and redundancy planning.<\/p>","protected":false},"featured_media":4961,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3010","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product\/3010","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/comments?post=3010"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media\/4961"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media?parent=3010"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_brand?post=3010"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_cat?post=3010"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_tag?post=3010"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}