{"id":2975,"date":"2026-08-02T15:24:43","date_gmt":"2026-08-02T15:24:43","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2975"},"modified":"2026-08-16T16:43:53","modified_gmt":"2026-08-16T08:43:53","slug":"daxin-3h3-400k-t-lf33-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/fr\/product\/daxin-3h3-400k-t-lf33-ups\/","title":{"rendered":"Onduleur en ligne basse fr\u00e9quence de 400 kVA | DAXIN 3H3 400K-T"},"content":{"rendered":"<h2>What Is the DAXIN 3H3 400K-T 400kVA Online UPS?<\/h2>\n<p>The DAXIN 3H3 400K-T is a 400kVA\/360kW low-frequency 3\/3 phase double-conversion online UPS designed for large industrial, data center, infrastructure and mission-critical power applications.<\/p>\n<p>Its three-phase input and three-phase output architecture supports facilities operating large three-phase critical loads. The reference configuration supports 380\/400\/415VAC operation, an input power factor greater than 0.99 and input current THDi below 3%.<\/p>\n<p>The UPS provides 400kVA apparent power and 360kW active power, with static output voltage stability of \u00b11%, dynamic voltage stability of \u00b15% within 10ms and a 3:1 crest factor.<\/p>\n<p>Battery technology, bypass configuration, communication interfaces and other project options should be confirmed according to the required backup time, site electrical system and approved DAXIN technical proposal.<\/p>\n<h2>Battery Configuration Options<\/h2>\n<p>The DAXIN 3H3 400K-T can be engineered with different energy-storage technologies according to project requirements.<\/p>\n<ul>\n<li>Valve-regulated sealed lead-acid batteries<\/li>\n<li>Nickel-cadmium batteries<\/li>\n<li>Supercapacitor systems<\/li>\n<li>Lithium battery systems<\/li>\n<li>Flywheel energy-storage systems<\/li>\n<\/ul>\n<p>The final battery technology, capacity and autonomy should be selected according to the connected load, required backup duration, operating environment, lifecycle requirements and project design.<\/p>\n<h2>Principaux avantages<\/h2>\n<ul>\n<li><strong>400kVA \/ 360kW Capacity:<\/strong>\u00a0Designed for large three-phase mission-critical loads.<\/li>\n<li><strong>Double-Conversion Online Architecture:<\/strong>\u00a0Provides continuous conditioned power for critical electrical equipment.<\/li>\n<li><strong>3\/3 Phase Configuration:<\/strong>\u00a0Three-phase input and three-phase output support large industrial and infrastructure electrical systems.<\/li>\n<li><strong>Grid-Friendly Input Performance:<\/strong>\u00a0Input power factor greater than 0.99 and input current THDi below 3% help reduce upstream electrical impact.<\/li>\n<li><strong>Sortie stable :<\/strong>\u00a0Static voltage stability of \u00b11% and dynamic voltage stability of \u00b15% within 10ms support sensitive critical loads.<\/li>\n<li><strong>Strong Overload Capability:<\/strong>\u00a0The reference specification supports 110% load for 60 minutes, 125% for 10 minutes and 150% for 1 minute.<\/li>\n<li><strong>Flexible Energy Storage:<\/strong>\u00a0Multiple battery and energy-storage technologies can be evaluated according to project requirements.<\/li>\n<li><strong>High-Efficiency Smart Mode:<\/strong>\u00a0Smart-mode efficiency is specified at up to 98.5%.<\/li>\n<\/ul>\n<h2>Que signifie \u00ab 3\/3 phases \u00bb dans un onduleur ?<\/h2>\n<p>Un onduleur triphas\u00e9 3\/3 utilise une alimentation triphas\u00e9e en courant alternatif en entr\u00e9e et fournit une alimentation triphas\u00e9e en courant alternatif en sortie.<\/p>\n<p>This architecture is commonly used for high-capacity critical loads in data centers, industrial plants, power infrastructure, transportation systems and other facilities operating large three-phase electrical equipment.<\/p>\n<p>The DAXIN 3H3 400K-T provides a 400kVA\/360kW three-phase online UPS platform for these large critical-power applications.<\/p>\n<h2>What Should Be Considered When Selecting a 400kVA UPS?<\/h2>\n<p>A 400kVA UPS should be selected from the actual critical-load profile rather than nominal capacity alone. Review the connected load in both kW and kVA, power factor, peak demand, future expansion and required operating margin.<\/p>\n<p>For large projects, also evaluate battery autonomy, bypass architecture, upstream and downstream protection coordination, generator compatibility, communication requirements, installation space, ventilation, floor loading and maintenance access.<\/p>\n<p>The DAXIN 3H3 400K-T provides 400kVA apparent power and 360kW active power. DAXIN ENERGY can review the load list, single-line diagram and site conditions before final system configuration.<\/p>\n<h2>\nPr\u00e9sentations des produits et documentation technique<\/h2>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4929\" aria-describedby=\"caption-attachment-4929\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4929\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-400K-T-1.webp\" alt=\"DAXIN 3H3 400K-T 400kVA Online UPS Technical Specifications\" width=\"970\" height=\"1068\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-400K-T-1.webp 970w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-400K-T-1-272x300.webp 272w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-400K-T-1-930x1024.webp 930w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-400K-T-1-768x846.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-400K-T-1-11x12.webp 11w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><figcaption id=\"caption-attachment-4929\" class=\"wp-caption-text\">Technical specifications for the DAXIN 3H3 400K-T 400kVA\/360kW three-phase online UPS.<\/figcaption><\/figure><figcaption>Enclosure and Connection Detail for DAXIN 3H3 400K-T Low-Frequency 3\/3 Phase UPS.<\/figcaption><\/figure>\n<h2>Applications typiques<\/h2>\n<ul>\n<li>Large data centers and mission-critical IT facilities<\/li>\n<li>Industrial manufacturing and process-control facilities<\/li>\n<li>Power generation and utility infrastructure<\/li>\n<li>Telecom core facilities<\/li>\n<li>Hospitals and healthcare campuses<\/li>\n<li>Transportation, railway and tunnel infrastructure<\/li>\n<li>Commercial and public infrastructure<\/li>\n<li>Other high-capacity three-phase critical-power systems<\/li>\n<\/ul>\n<h2>S\u00e9lection et planification du projet<\/h2>\n<p>Avant de passer commande, v\u00e9rifiez que la puissance nominale exacte, la phase d'entr\u00e9e\/sortie, la tension, la fr\u00e9quence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la m\u00e9thode d'installation correspondent bien au mod\u00e8le s\u00e9lectionn\u00e9 et aux plans du projet.<\/p>\n<h2>Foire aux questions<\/h2>\n<p>Ce produit peut-il \u00eatre configur\u00e9 pour un projet sp\u00e9cifique ?<\/p>\n<p>Oui. La configuration \u00e9lectrique, l'autonomie de la batterie, les syst\u00e8mes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent \u00eatre examin\u00e9s en fonction des exigences du site.<\/p>\n<p>Les notes techniques sont-elles toutes communes \u00e0 l'ensemble de la s\u00e9rie ?<\/p>\n<p>Non. Les caract\u00e9ristiques techniques et les fonctions varient selon le mod\u00e8le et la configuration. Veuillez vous r\u00e9f\u00e9rer \u00e0 la fiche technique sp\u00e9cifique au projet comme r\u00e9f\u00e9rence d\u00e9finitive.<\/p>\n<p>DAXIN ENERGY peut-elle vous aider \u00e0 choisir un syst\u00e8me ?<\/p>\n<p>Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la dur\u00e9e de fonctionnement requise, l'objectif de redondance, les exigences en mati\u00e8re de communication et l'environnement d'installation.<\/p>\n<h3>Demander une configuration de projet<\/h3>\n<p>Envoyez-nous les donn\u00e9es de charge, le sch\u00e9ma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"11uftra\" data-start=\"8909\" data-end=\"8964\">What is the rated capacity of the DAXIN 3H3 400K-T?<\/h3>\n<p data-start=\"8966\" data-end=\"9017\">The reference model is rated at 400kVA \/ 360kW.<\/p>\n<h3 data-section-id=\"1ngics\" data-start=\"9019\" data-end=\"9072\">Is the 3H3 400K-T a double-conversion online UPS?<\/h3>\n<p data-start=\"9074\" data-end=\"9176\">Yes. The supplied technical specification classifies the system as a double-conversion online UPS.<\/p>\n<h3 data-section-id=\"zp921o\" data-start=\"9178\" data-end=\"9228\">What input and output voltage does it support?<\/h3>\n<p data-start=\"9230\" data-end=\"9353\">The reference configuration specifies 380\/400\/415VAC three-phase input and 380\/400\/415VAC three-phase + neutral output.<\/p>\n<h3 data-section-id=\"14dm6cu\" data-start=\"9355\" data-end=\"9399\">What is the input power factor and THDi?<\/h3>\n<p data-start=\"9401\" data-end=\"9511\">The reference specification lists an input power factor greater than 0.99 and input current THDi below 3%.<\/p>\n<h3 data-section-id=\"38ux4i\" data-start=\"9513\" data-end=\"9555\">What battery technologies can be used?<\/h3>\n<p data-start=\"9557\" data-end=\"9704\">The specification lists sealed lead-acid, nickel-cadmium, supercapacitor, lithium and flywheel options. Final selection depends on the project.<\/p>\n<h3 data-section-id=\"ia6309\" data-start=\"9706\" data-end=\"9751\">What is the efficiency of the 3H3 400K-T?<\/h3>\n<p data-start=\"9753\" data-end=\"9893\">Smart-mode efficiency is specified at up to 98.5%. Actual operating efficiency depends on operating mode, load and system configuration.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN 3H3 400K-T is a 400kVA\/360kW low-frequency 3\/3 phase double-conversion online UPS designed for large industrial, data center and infrastructure critical-power applications. It supports 380\/400\/415VAC three-phase operation, &gt;0.99 input power factor, &lt;3% input current THDi, configurable battery technologies and smart-mode efficiency up to 98.5%.<\/p>","protected":false},"featured_media":4931,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[109,99,97],"product_tag":[],"class_list":["post-2975","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-low-frequency-3-3-phase-ups","product_cat-low-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product\/2975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/comments?post=2975"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media\/4931"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media?parent=2975"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_brand?post=2975"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_cat?post=2975"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_tag?post=2975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}