{"id":2260,"date":"2026-07-11T09:34:05","date_gmt":"2026-07-11T09:34:05","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=2260"},"modified":"2026-07-11T09:34:06","modified_gmt":"2026-07-11T09:34:06","slug":"daxin-energy-ex3c3-onduleur-triphase-en-ligne-de-180-kva","status":"publish","type":"product","link":"https:\/\/btrytech.com\/fr\/product\/daxin-energy-ex3c3-180kva-three-phase-online-ups\/","title":{"rendered":"Onduleur triphas\u00e9 en ligne DAXIN ENERGY EX3C3 180 kVA"},"content":{"rendered":"<h2>EX3C3 180kVA Three-Phase Online UPS<\/h2>\n<p>The DAXIN ENERGY EX3C3 180kVA online UPS is engineered for large-scale critical power backup applications that require reliable three-phase power, high efficiency and stable system operation. Its double-conversion online topology helps isolate sensitive equipment from grid fluctuation, voltage instability, frequency variation, harmonic interference and unexpected power interruptions.<\/p>\n<h2>Principales caract\u00e9ristiques<\/h2>\n<h3>High-Reliability Online Double-Conversion Design<\/h3>\n<ul>\n<li>True online double-conversion topology delivers clean sine wave output for critical loads.<\/li>\n<li>Output frequency tracking, phase locking, voltage regulation and noise filtering reduce the impact of unstable grid power.<\/li>\n<li>Le syst\u00e8me de commande modulaire avanc\u00e9 \u00e0 double processeur am\u00e9liore la fiabilit\u00e9 et la stabilit\u00e9 de fonctionnement du syst\u00e8me.<\/li>\n<li>Wide AC input voltage range helps reduce unnecessary battery discharge in poor power environments.<\/li>\n<li>La fonction de d\u00e9marrage en courant continu permet \u00e0 l'onduleur de d\u00e9marrer directement \u00e0 partir de la batterie lorsque le r\u00e9seau \u00e9lectrique est indisponible.<\/li>\n<\/ul>\n<h3>High Efficiency and Grid-Friendly Performance<\/h3>\n<ul>\n<li>Advanced PFC technology keeps the input power factor close to 1.<\/li>\n<li>La conception d'un filtre d'harmoniques d'entr\u00e9e contribue \u00e0 r\u00e9duire la pollution par r\u00e9troaction vers le r\u00e9seau \u00e9lectrique public.<\/li>\n<li>Input and output harmonic filters minimize harmonic interference caused by the UPS system.<\/li>\n<li>High-frequency filtering and synchronization technology improves compatibility with generator power.<\/li>\n<\/ul>\n<h3>Complete Protection Functions<\/h3>\n<ul>\n<li>Protection contre les surcharges en sortie.<\/li>\n<li>Protection contre les courts-circuits en sortie.<\/li>\n<li>Protection contre la surchauffe de l'onduleur.<\/li>\n<li>Protection contre les alertes de tension faible de la batterie.<\/li>\n<li>Protection contre la surcharge de la batterie.<\/li>\n<li>Manual maintenance bypass switch supports easier maintenance without interrupting load power.<\/li>\n<\/ul>\n<h3>LCD Display and Intelligent Management<\/h3>\n<ul>\n<li>L'\u00e9cran LCD affiche en temps r\u00e9el l'\u00e9tat de fonctionnement de l'onduleur, les param\u00e8tres du syst\u00e8me et les informations relatives aux alarmes.<\/li>\n<li>Les interfaces de communication RS232 \/ RS485 permettent la surveillance locale et l'int\u00e9gration au syst\u00e8me.<\/li>\n<li>Une carte r\u00e9seau SNMP en option permet la surveillance \u00e0 distance de l'onduleur et la gestion centralis\u00e9e de l'alimentation.<\/li>\n<li>Compatible with intelligent UPS monitoring software for clear visibility of operating data.<\/li>\n<\/ul>\n<h3>Module optionnel de surveillance intelligente de la batterie<\/h3>\n<ul>\n<li>Prend en charge la d\u00e9tection et la surveillance d'une seule batterie.<\/li>\n<li>Offre des fonctions d'alarme en cas de surtension, de sous-tension et de diff\u00e9rence de tension.<\/li>\n<li>Les informations relatives aux dysfonctionnements de la batterie peuvent s'afficher \u00e0 l'\u00e9cran afin d'aider les administrateurs \u00e0 r\u00e9agir rapidement.<\/li>\n<\/ul>\n<h3>Grande capacit\u00e9 d'adaptation \u00e0 l'environnement<\/h3>\n<p>The circuit boards are installed in a fully enclosed structure and treated with conformal coating, improving reliability in harsh environments such as tunnels, plazas, industrial sites and infrastructure facilities.<\/p>\n<h2>Applications typiques<\/h2>\n<ul>\n<li>Grands centres de donn\u00e9es et salles de serveurs<\/li>\n<li>Industrial automation and manufacturing facilities<\/li>\n<li>Telecom core equipment rooms<\/li>\n<li>H\u00f4pitaux et syst\u00e8mes de sant\u00e9<\/li>\n<li>Projets d'infrastructures de transport et de tunnels<\/li>\n<li>Commercial buildings and large office parks<\/li>\n<li>Syst\u00e8mes d'alimentation de secours<\/li>\n<\/ul>\n<h2>Caract\u00e9ristiques techniques<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Mod\u00e8le<\/th>\n<td>EX3C3-180 kVA<\/td>\n<\/tr>\n<tr>\n<th>Capacit\u00e9<\/th>\n<td>180kVA \/ 180kW<\/td>\n<\/tr>\n<tr>\n<th>Topologie<\/th>\n<td>Onduleur \u00e0 double conversion en ligne<\/td>\n<\/tr>\n<tr>\n<th>Phase d'entr\u00e9e<\/th>\n<td>Triphas\u00e9 + neutre<\/td>\n<\/tr>\n<tr>\n<th>Plage de tension d'entr\u00e9e<\/th>\n<td>110 V CA (phase-neutre) \u00b131 TP3T pour une charge de 501 TP3T ; 176 V CA (phase-neutre) \u00b131 TP3T pour une charge de 1001 TP3T<\/td>\n<\/tr>\n<tr>\n<th>Fr\u00e9quence d'entr\u00e9e<\/th>\n<td>50 \/ 60 Hz, s\u00e9lection automatique<\/td>\n<\/tr>\n<tr>\n<th>Facteur de puissance d'entr\u00e9e<\/th>\n<td>&gt; 0,99 \u00e0 une charge de 100%<\/td>\n<\/tr>\n<tr>\n<th>Tension de sortie<\/th>\n<td>380 \/ 400 \/ 415 V CA, triphas\u00e9<\/td>\n<\/tr>\n<tr>\n<th>R\u00e9gulation de la tension alternative<\/th>\n<td>+\/-0.3%<\/td>\n<\/tr>\n<tr>\n<th>Fr\u00e9quence de sortie<\/th>\n<td>46-54 Hz ou 56-64 Hz en mode synchronis\u00e9 ; 50 Hz \u00b1 0,1 Hz ou 60 Hz \u00b1 0,1 Hz en mode batterie<\/td>\n<\/tr>\n<tr>\n<th>Facteur de cr\u00eate<\/th>\n<td>3:1<\/td>\n<\/tr>\n<tr>\n<th>THD de sortie<\/th>\n<td>&lt;=1% avec une charge lin\u00e9aire ; &lt;=2% avec une charge non lin\u00e9aire<\/td>\n<\/tr>\n<tr>\n<th>Dur\u00e9e du transfert<\/th>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<th>Efficacit\u00e9<\/th>\n<td>&gt; 96,51 TP3T en mode secteur ; &gt; 96,51 TP3T en mode batterie<\/td>\n<\/tr>\n<tr>\n<th>Nombre de piles<\/th>\n<td>32 \u00e0 40 pi\u00e8ces, r\u00e9glable<\/td>\n<\/tr>\n<tr>\n<th>Courant de charge<\/th>\n<td>3-54A \u00b110%, pr\u00e9r\u00e9glage 3 A<\/td>\n<\/tr>\n<tr>\n<th>Dimensions<\/th>\n<td>1 000 \u00d7 600 \u00d7 1 200 mm<\/td>\n<\/tr>\n<tr>\n<th>Poids net<\/th>\n<td>265 kg<\/td>\n<\/tr>\n<tr>\n<th>Temp\u00e9rature de fonctionnement<\/th>\n<td>0 \u00e0 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Humidit\u00e9 relative<\/th>\n<td>&lt; 95%, sans condensation<\/td>\n<\/tr>\n<tr>\n<th>Bruit<\/th>\n<td>&lt; 75 dB \u00e0 1 m<\/td>\n<\/tr>\n<tr>\n<th>Communication<\/th>\n<td>RS232 \/ RS485 \/ USB, SNMP en option<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure id=\"attachment_2264\" aria-describedby=\"caption-attachment-2264\" style=\"width: 2400px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2264\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english.png\" alt=\"DAXIN ENERGY EX3C3 180kVA three-phase online UPS technical specifications\" width=\"2400\" height=\"2200\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english.png 2400w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english-300x275.png 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english-1024x939.png 1024w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english-768x704.png 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english-1536x1408.png 1536w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english-2048x1877.png 2048w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english-13x12.png 13w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-180kva-three-phase-online-ups-technical-specifications-english-1200x1100.png 1200w\" sizes=\"auto, (max-width: 2400px) 100vw, 2400px\" \/><figcaption id=\"caption-attachment-2264\" class=\"wp-caption-text\">Technical specifications for DAXIN ENERGY EX3C3 series three-phase online UPS, including the 180kVA model.<\/figcaption><\/figure>\n<figure id=\"attachment_2223\" aria-describedby=\"caption-attachment-2223\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2223\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-3h10kva-online-ups-social-image-1200x630-1.png\" alt=\"Image de partage sur les r\u00e9seaux sociaux de l&#039;onduleur en ligne DAXIN ENERGY 3H10kVA, destin\u00e9 aux applications d&#039;alimentation de secours critique et aux onduleurs industriels\" width=\"1200\" height=\"631\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-3h10kva-online-ups-social-image-1200x630-1.png 1200w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-3h10kva-online-ups-social-image-1200x630-1-300x158.png 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-3h10kva-online-ups-social-image-1200x630-1-1024x538.png 1024w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-3h10kva-online-ups-social-image-1200x630-1-768x404.png 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-3h10kva-online-ups-social-image-1200x630-1-18x9.png 18w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-2223\" class=\"wp-caption-text\">Social sharing image for DAXIN ENERGY 3H10kVA online UPS, designed for data centers, telecom power rooms and industrial backup power.<\/figcaption><\/figure>","protected":false},"excerpt":{"rendered":"<p>DAXIN ENERGY EX3C3 180kVA three-phase online UPS provides high-efficiency, double-conversion power protection for data centers, industrial facilities, telecom systems, hospitals, transportation infrastructure and mission-critical commercial applications. With wide AC input voltage range, high input power factor, LCD monitoring, RS232 \/ RS485 communication and optional SNMP management, it delivers clean, stable and continuous power for critical equipment.<\/p>","protected":false},"featured_media":2263,"comment_status":"open","ping_status":"closed","template":"","meta":{"_crdt_document":""},"product_brand":[46,622],"product_cat":[98,104],"product_tag":[],"class_list":["post-2260","product","type-product","status-publish","has-post-thumbnail","product_brand-szdxzh","product_brand-daxin-energy","product_cat-high-frequency-ups","product_cat-hf-3-3-phase-ups","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product\/2260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/comments?post=2260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media\/2263"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media?parent=2260"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_brand?post=2260"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_cat?post=2260"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_tag?post=2260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}