Description
What Is the DAXIN RM33 200kVA Modular Online UPS?
The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.
Its modular cabinet architecture integrates power modules, system control, protection and service access within a scalable UPS platform. The reference configuration provides 200kW cabinet capacity and supports external battery packs for project-specific backup requirements.
The RM33 series supports 3 × 380/400/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.
Final installed capacity, power-module configuration, battery runtime, redundancy architecture, communications and project accessories should be confirmed against the approved DAXIN technical proposal.
| Paramètre | RM33-200kVA |
|---|---|
| Modèle | RM33-200kVA |
| UPS Type | Modular Online UPS |
| Phase | Three-Phase Input / Three-Phase Output |
| Cabinet Capacity | 200kW |
| Type de batterie | External Battery Pack |
| Battery Cabinet Capacity | 20kVA / 20kW |
| Optional Battery Cabinets | 10 |
| Tension d'entrée | 3 × 380/400/415VAC (3PH+N) |
| Fréquence d'entrée | 50/60Hz Auto-Detect |
| Plage de fréquences d'entrée | 40–70Hz |
| Facteur de puissance d'entrée | ≥0.99 @ 100% Load |
| Input Current THDi | <2% @ 100% Load |
| Tension de sortie | 3 × 380/400/415VAC (3PH+N) |
| Static Voltage Stability | ≤±0.3% Typical Load |
| Dynamic Voltage Stability | ≤±3% Typical Load |
| Fréquence de sortie | 50/60 Hz |
| THD de sortie | ≤1% Linear / ≤2% Non-linear |
| Efficacité | Jusqu'à 96,51 TP3T |
| Dimensions | 1100 × 600 × 2010mm |
| Poids net | 282kg |
| Température de fonctionnement | 0 à 40 °C |
| Altitude | <1000m Rated Power |
| Indice de protection | IP20 |
| Communication | RS-232 / USB |
| Gestion du réseau | SNMP (en option) |

Principaux avantages
- Scalable Modular Architecture: Modular UPS design supports flexible capacity planning and future system expansion.
- 200kW Cabinet Capacity: The RM33-200kVA reference cabinet is designed for large three-phase critical-power applications.
- Three-Phase Power Protection: Supports 3 × 380/400/415VAC three-phase input and output for data center, telecom and industrial electrical systems.
- Low Input Harmonic Distortion: Input current THDi below 2% at full load helps reduce upstream electrical impact.
- High Input Power Factor: Input power factor is at least 0.99 at 100% load.
- High Efficiency: System efficiency is specified at up to 96.5%.
- External Battery Configuration: Battery systems can be engineered according to required backup runtime and project requirements.
- Remote Monitoring: RS-232/USB communication is supported, with optional SNMP network management.
What Is a Modular UPS System?
A modular UPS system uses multiple power modules within a common cabinet architecture instead of relying on a single fixed-capacity power stage.
This approach allows UPS capacity, maintenance strategy and redundancy architecture to be planned according to the critical load and future expansion requirements.
The DAXIN RM33 series combines modular power architecture with centralized control, external battery systems and network-management options for scalable critical-power applications.
Why Choose a 200kVA Modular UPS for a Data Center?
A modular UPS can help data center operators align installed power capacity with the actual critical load while preserving a path for future expansion and redundancy planning.
The DAXIN RM33-200kVA combines three-phase online power protection, modular system architecture, external battery configuration and optional network monitoring for data center and mission-critical infrastructure applications.
Final system sizing should consider the IT load in kW and kVA, power factor, redundancy target, expected expansion, required battery autonomy and upstream electrical architecture.
Applications typiques
- Centres de données et salles de serveurs
- Telecom core facilities and network infrastructure
- Industrial automation and manufacturing plants
- Financial and banking facilities
- Healthcare and medical infrastructure
- Transportation and public infrastructure
- Enterprise IT facilities
- Other scalable mission-critical power systems
Sélection et planification du projet
Avant de passer commande, vérifiez que la puissance nominale exacte, la phase d'entrée/sortie, la tension, la fréquence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la méthode d'installation correspondent bien au modèle sélectionné et aux plans du projet.
Foire aux questions
Ce produit peut-il être configuré pour un projet spécifique ?
Oui. La configuration électrique, l'autonomie de la batterie, les systèmes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent être examinés en fonction des exigences du site.
Les notes techniques sont-elles toutes communes à l'ensemble de la série ?
Non. Les caractéristiques techniques et les fonctions varient selon le modèle et la configuration. Veuillez vous référer à la fiche technique spécifique au projet comme référence définitive.
DAXIN ENERGY peut-elle vous aider à choisir un système ?
Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la durée de fonctionnement requise, l'objectif de redondance, les exigences en matière de communication et l'environnement d'installation.
Demander une configuration de projet
Envoyez-nous les données de charge, le schéma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.
What is the DAXIN RM33-200kVA?
The DAXIN RM33-200kVA is a three-phase modular online UPS system designed for scalable critical-power applications.
What is the cabinet capacity?
The supplied RM33 series specification lists 200kW cabinet capacity for the RM33-200kVA configuration.
What input and output voltage does it support?
The reference specification lists 3 × 380/400/415VAC three-phase input and output.
What are the input power factor and THDi?
The reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.
Does the RM33 support remote monitoring?
Yes. RS-232/USB communication is supported, and SNMP network management is available as an option.
How should the RM33-200kVA system be configured?
Final configuration should consider the critical load, required redundancy, future expansion, battery runtime, electrical distribution, communication requirements and installation environment.







Avis