{"id":3010,"date":"2026-08-02T15:27:43","date_gmt":"2026-08-02T15:27:43","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3010"},"modified":"2026-08-17T20:23:53","modified_gmt":"2026-08-17T12:23:53","slug":"daxin-rm33-300kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/es\/product\/daxin-rm33-300kva-system-ups\/","title":{"rendered":"300kVA Modular Online UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 300kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large data centers, telecom facilities, industrial plants and other mission-critical power applications.<\/p>\n<p>Its modular architecture integrates scalable power modules, centralized control, protection and service access within a common UPS platform, allowing installed capacity and redundancy to be planned according to the critical load and future expansion requirements.<\/p>\n<p>The RM33-300kVA reference configuration provides 300kW cabinet capacity and supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load and external battery configurations.<\/p>\n<p>Final power-module configuration, battery autonomy, redundancy architecture, bypass, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.<\/p>\n<h2>Ventajas principales<\/h2>\n<ul>\n<li><strong>300kW Cabinet Capacity:<\/strong>\u00a0Designed for large three-phase mission-critical power systems.<\/li>\n<li><strong>Scalable Modular Architecture:<\/strong>\u00a0Power-module configuration can be planned according to current load, redundancy requirements and future expansion.<\/li>\n<li><strong>Three-Phase Online Power Protection:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/li>\n<li><strong>High Input Power Factor:<\/strong>\u00a0Input power factor is specified at \u22650.99 at full load and \u22650.98 at 50% load.<\/li>\n<li><strong>External Battery Architecture:<\/strong>\u00a0Battery capacity and backup autonomy can be engineered according to project requirements.<\/li>\n<li><strong>Flexible Redundancy Planning:<\/strong>\u00a0Modular architecture supports system designs based on required availability and future capacity growth.<\/li>\n<li><strong>Network Management:<\/strong>\u00a0Optional SNMP supports centralized UPS monitoring and power management.<\/li>\n<li><strong>Large Critical-Power Applications:<\/strong>\u00a0Suitable for data centers, telecom, industrial facilities and other high-availability infrastructure.<\/li>\n<\/ul>\n<h2>What Is a Modular UPS System?<\/h2>\n<p>A modular UPS system uses multiple power modules within a common UPS platform instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This architecture allows installed capacity, redundancy and future expansion to be planned according to the critical load and required system availability.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and optional network management for scalable critical-power applications.<\/p>\n<h2>How Should a 300kVA Modular UPS Be Sized?<\/h2>\n<p>A 300kVA modular UPS should be sized according to the actual critical load in both kW and kVA, load power factor, required redundancy, operating margin, expected future expansion and battery autonomy.<\/p>\n<p>For large data center and industrial projects, system design should also consider power-module configuration, bypass architecture, upstream and downstream protection, generator compatibility, battery capacity, communications and maintenance requirements.<\/p>\n<p>DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 modular UPS configuration.<\/p>\n<h2>Why Use a Modular UPS for Large Data Centers?<\/h2>\n<p>Modular UPS architecture allows data center operators to align installed power capacity with the actual critical load while preserving flexibility for redundancy and future expansion.<\/p>\n<p>For growing facilities, additional capacity can be planned within the supported system architecture instead of treating every future load increase as a completely separate UPS project.<\/p>\n<p>The DAXIN RM33 modular UPS platform is designed for scalable three-phase critical-power applications with external battery systems and network-management options.<\/p>\n<h2>\nDAXIN RM33-300kVA Key Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>Especificaciones<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Modelo<\/strong><\/td>\n<td><strong>RM33-300kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>UPS Type<\/td>\n<td>Modular Online UPS<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>Three-Phase Input \/ Three-Phase Output<\/td>\n<\/tr>\n<tr>\n<td>Cabinet Capacity<\/td>\n<td><strong>300kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Tipo de bater\u00eda<\/td>\n<td>External Battery Pack<\/td>\n<\/tr>\n<tr>\n<td>Single Battery Cabinet Capacity<\/td>\n<td>50kVA\/60kVA (50kW\/60kW)<\/td>\n<\/tr>\n<tr>\n<td>Optional Battery Cabinets<\/td>\n<td>6 \/ 5<\/td>\n<\/tr>\n<tr>\n<td>Tensi\u00f3n de entrada<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Rango de tensi\u00f3n<\/td>\n<td>110\u2013300VAC @ 50% Load; 176\u2013276VAC @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Rated Frequency<\/td>\n<td>50\/60Hz Auto-Detect<\/td>\n<\/tr>\n<tr>\n<td>Rango de frecuencias<\/td>\n<td>40\u201370Hz<\/td>\n<\/tr>\n<tr>\n<td>Factor de potencia de entrada<\/td>\n<td>\u22650.99 @ 100% Load; \u22650.98 @ 50% Load<\/td>\n<\/tr>\n<tr>\n<td>Input THDi<\/td>\n<td>&lt;4% @ 100% Load with 50kW Module<\/td>\n<\/tr>\n<tr>\n<td>Tensi\u00f3n de salida<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Static Voltage Stability<\/td>\n<td>\u2264\u00b11% Balanced; \u2264\u00b12% Unbalanced<\/td>\n<\/tr>\n<tr>\n<td>Frecuencia de salida<\/td>\n<td>50\u201360Hz<\/td>\n<\/tr>\n<tr>\n<td>Rango de frecuencias<\/td>\n<td>46\u201354Hz or 56\u201364Hz<\/td>\n<\/tr>\n<tr>\n<td>Distorsi\u00f3n arm\u00f3nica total (THD) de salida<\/td>\n<td>\u22642% Linear; \u22644% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Eficiencia<\/td>\n<td><strong>95.5% with 50kW Module<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Tensi\u00f3n de la bater\u00eda<\/td>\n<td>\u00b1192V to \u00b1240V Optional<\/td>\n<\/tr>\n<tr>\n<td>Max. Charge Current<\/td>\n<td>18A Adjustable per Battery Cabinet<\/td>\n<\/tr>\n<tr>\n<td>Dimensiones<\/td>\n<td><strong>1065 \u00d7 600 \u00d7 2010mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Peso neto<\/td>\n<td><strong>287 \/ 297kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Temperatura de funcionamiento<\/td>\n<td>0\u201340\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humedad relativa<\/td>\n<td>0\u201395%, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td>Altitud<\/td>\n<td>&lt;1000m at Rated Power<\/td>\n<\/tr>\n<tr>\n<td>\u00cdndice de protecci\u00f3n<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Network Management<\/td>\n<td>SNMP opcional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\"><figcaption>\n<figure id=\"attachment_4953\" aria-describedby=\"caption-attachment-4953\" style=\"width: 836px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4953\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp\" alt=\"DAXIN RM33 60-600kVA Modular Online UPS Technical Specifications\" width=\"836\" height=\"1880\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp 836w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-133x300.webp 133w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-455x1024.webp 455w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-768x1727.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-683x1536.webp 683w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-5x12.webp 5w\" sizes=\"auto, (max-width: 836px) 100vw, 836px\" \/><figcaption id=\"caption-attachment-4953\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 60-600kVA three-phase modular online UPS series.<\/figcaption><\/figure>\n<p>Control Panel and Front Detail for DAXIN RM33-300kVA Modular UPS System Cabinet.<\/p>\n<\/figcaption><\/figure>\n<h2>Aplicaciones t\u00edpicas<\/h2>\n<ul>\n<li>Large data centers and server facilities<\/li>\n<li>Telecom core networks and communication facilities<\/li>\n<li>Industrial automation and manufacturing plants<\/li>\n<li>Financial and banking infrastructure<\/li>\n<li>Healthcare and medical facilities<\/li>\n<li>Transportation and public infrastructure<\/li>\n<li>Enterprise IT and cloud infrastructure<\/li>\n<li>Other large mission-critical three-phase power systems<\/li>\n<\/ul>\n<h2>Selecci\u00f3n y planificaci\u00f3n del proyecto<\/h2>\n<p>Antes de realizar el pedido, compruebe que la potencia nominal exacta, la fase de entrada\/salida, la tensi\u00f3n, la frecuencia, el factor de potencia, la tensi\u00f3n de la bater\u00eda, el tiempo de autonom\u00eda, el modo de derivaci\u00f3n, las comunicaciones, las dimensiones, los l\u00edmites ambientales y el m\u00e9todo de instalaci\u00f3n se ajusten al modelo seleccionado y a los planos del proyecto.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>\u00bfSe puede configurar este producto para un proyecto concreto?<\/h3>\n<p>S\u00ed. La configuraci\u00f3n el\u00e9ctrica, la autonom\u00eda de la bater\u00eda, las comunicaciones, el sistema de derivaci\u00f3n, la disposici\u00f3n de los armarios y los accesorios del proyecto pueden revisarse en funci\u00f3n de los requisitos de la instalaci\u00f3n.<\/p>\n<h3>\u00bfSe aplican todas las clasificaciones t\u00e9cnicas a toda la serie?<\/h3>\n<p>No. Las caracter\u00edsticas t\u00e9cnicas y las funciones var\u00edan seg\u00fan el modelo y la configuraci\u00f3n. Utilice la ficha t\u00e9cnica espec\u00edfica del proyecto como referencia definitiva.<\/p>\n<h3>\u00bfPuede DAXIN ENERGY ayudar en la selecci\u00f3n del sistema?<\/h3>\n<p>S\u00ed. Facilite la lista de cargas, la fase y la tensi\u00f3n, el tiempo de funcionamiento requerido, el objetivo de redundancia, los requisitos de comunicaci\u00f3n y el entorno de instalaci\u00f3n.<\/p>\n<h3>Solicitar una configuraci\u00f3n de proyecto<\/h3>\n<p>Env\u00edenos los datos de carga, el esquema unifilar, el tiempo de autonom\u00eda necesario y las condiciones del emplazamiento para recibir una propuesta personalizada de SAI o bater\u00edas.<\/p>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"9315\" data-end=\"9473\"><strong data-start=\"9315\" data-end=\"9349\">What is the DAXIN RM33 300kVA?<\/strong><br data-start=\"9349\" data-end=\"9352\" \/>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large scalable critical-power applications.<\/p>\n<p data-start=\"9475\" data-end=\"9584\"><strong data-start=\"9475\" data-end=\"9508\">What is the cabinet capacity?<\/strong><br data-start=\"9508\" data-end=\"9511\" \/>The RM33-300kVA reference configuration specifies 300kW cabinet capacity.<\/p>\n<p data-start=\"9586\" data-end=\"9721\"><strong data-start=\"9586\" data-end=\"9636\">What input and output voltage does it support?<\/strong><br data-start=\"9636\" data-end=\"9639\" \/>The reference specification lists 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/p>\n<p data-start=\"9723\" data-end=\"9867\"><strong data-start=\"9723\" data-end=\"9758\">What is the input power factor?<\/strong><br data-start=\"9758\" data-end=\"9761\" \/>The specification lists an input power factor of at least 0.99 at 100% load and at least 0.98 at 50% load.<\/p>\n<p data-start=\"9869\" data-end=\"10062\"><strong data-start=\"9869\" data-end=\"9914\">Does the RM33 support external batteries?<\/strong><br data-start=\"9914\" data-end=\"9917\" \/>Yes. The RM33-300kVA uses an external battery architecture, with final battery capacity and runtime engineered according to project requirements.<\/p>\n<p data-start=\"10064\" data-end=\"10216\"><strong data-start=\"10064\" data-end=\"10114\">Can the RM33-300kVA support remote monitoring?<\/strong><br data-start=\"10114\" data-end=\"10117\" \/>Yes. Optional SNMP network management is available for centralized power monitoring and management.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. With 300kW cabinet capacity, 380\/400\/415VAC three-phase operation, external battery configurations and optional SNMP monitoring, it supports large mission-critical power systems requiring flexible capacity and redundancy planning.<\/p>","protected":false},"featured_media":4961,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3010","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product\/3010","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/comments?post=3010"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media\/4961"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media?parent=3010"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_brand?post=3010"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_cat?post=3010"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_tag?post=3010"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}