{"id":2913,"date":"2026-08-02T15:17:25","date_gmt":"2026-08-02T15:17:25","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2913"},"modified":"2026-09-02T15:57:51","modified_gmt":"2026-09-02T07:57:51","slug":"10kva-low-frequency-online-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/es\/product\/10kva-low-frequency-online-ups\/","title":{"rendered":"10kVA Low-Frequency Online UPS | DAXIN 1\/1 10K(L)"},"content":{"rendered":"<h2 style=\"text-align: center;\">DAXIN 10kVA Low-Frequency Online UPS Video<\/h2>\n<div style=\"width: 100%; text-align: center; margin: 20px auto;\">\n<div style=\"display: inline-block; max-width: 100%;\">\n<div style=\"width: 240px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-2913-1\" width=\"240\" height=\"427\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10kVA-Low-Frequency-v5.mp4?_=1\" \/><a href=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10kVA-Low-Frequency-v5.mp4\">https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10kVA-Low-Frequency-v5.mp4<\/a><\/video><\/div>\n<\/div>\n<\/div>\n<p style=\"max-width: 760px; margin: 16px auto; text-align: center;\">Watch the DAXIN 10kVA low-frequency online UPS in operation. Contact our engineering team for specifications, backup time calculation, battery configuration, pricing, and OEM\/ODM support.<\/p>\n<h2>What Is the DAXIN 1\/1 10K(L) 10kVA Online UPS?<\/h2>\n<p>The DAXIN 1\/1 10K(L) is a 10kVA\/8kW online UPS designed for critical applications requiring single-phase input and single-phase output power protection.<\/p>\n<p>Its 1\/1 phase architecture matches facilities where both the incoming utility supply and protected critical loads operate on single-phase power.<\/p>\n<p>The reference configuration provides 208\/220\/230VAC output, \u00b11% voltage regulation, 0ms mains-to-battery transfer, 88% AC-mode efficiency and 92% battery-mode efficiency.<\/p>\n<p>The UPS supports configurable 16\/18-battery operation, RS-232\/USB communication and optional SNMP network management. Battery configuration, runtime and project options should be selected according to the connected load and required backup duration.<\/p>\n<h2>Ventajas principales<\/h2>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><strong>10kVA \/ 8kW Capacity:<\/strong> Designed for critical single-phase loads requiring up to 8kW rated active power.<\/li>\n<li><strong>1\/1 Phase Architecture:<\/strong> Single-phase input and single-phase output match common single-phase critical-power applications.<\/li>\n<li><strong>Protecci\u00f3n el\u00e9ctrica en l\u00ednea:<\/strong> Provides continuous power conditioning for sensitive electrical and electronic loads.<\/li>\n<li><strong>0ms Transfer Time:<\/strong> Maintains output during mains-to-battery transition according to the reference specification.<\/li>\n<li><strong>Stable Output:<\/strong> Supports 208\/220\/230VAC output with \u00b11% voltage regulation.<\/li>\n<li><strong>Sistema de bater\u00edas configurable:<\/strong> Supports 16\/18-battery configurations with charging options according to project requirements.<\/li>\n<li><strong>Communication and Monitoring:<\/strong> RS-232\/USB communication with optional SNMP network management.<\/li>\n<li><strong>Configuraci\u00f3n basada en proyectos:<\/strong> Battery runtime and other system requirements can be reviewed according to the connected load and site conditions.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2>DAXIN 1\/1 10K(L) Key Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>1\/1 10K(L)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Capacidad nominal<\/strong><\/td>\n<td><strong>10kVA \/ 8kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>Single Phase Input \/ Single Phase Output<\/td>\n<\/tr>\n<tr>\n<td>Tensi\u00f3n de salida<\/td>\n<td>208 \/ 220 \/ 230VAC<\/td>\n<\/tr>\n<tr>\n<td>Regulaci\u00f3n de tensi\u00f3n<\/td>\n<td>\u00b11%<\/td>\n<\/tr>\n<tr>\n<td>Battery-Mode Frequency<\/td>\n<td>50 Hz \u00b10,1 Hz o 60 Hz \u00b10,1 Hz<\/td>\n<\/tr>\n<tr>\n<td>Factor de cresta<\/td>\n<td>3:1 Max<\/td>\n<\/tr>\n<tr>\n<td>Distorsi\u00f3n arm\u00f3nica total (THD) de salida<\/td>\n<td>\u22643% Linear \/ \u22645% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Mains-to-Battery Transfer<\/td>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<td>Inverter-to-Bypass Transfer<\/td>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<td>AC Mode Efficiency<\/td>\n<td>88%<\/td>\n<\/tr>\n<tr>\n<td>Battery Mode Efficiency<\/td>\n<td>92%<\/td>\n<\/tr>\n<tr>\n<td>N\u00famero de bater\u00edas<\/td>\n<td>16 \/ 18 pcs<\/td>\n<\/tr>\n<tr>\n<td>Corriente m\u00e1xima de carga<\/td>\n<td>8A<\/td>\n<\/tr>\n<tr>\n<td>Dimensiones<\/td>\n<td>562 \u00d7 250 \u00d7 830 mm<\/td>\n<\/tr>\n<tr>\n<td>Peso neto<\/td>\n<td>86 kg<\/td>\n<\/tr>\n<tr>\n<td>Temperatura de funcionamiento<\/td>\n<td>0\u201350\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humedad relativa<\/td>\n<td>&lt;95%, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td>Altitud de funcionamiento<\/td>\n<td>&lt;1000 m<\/td>\n<\/tr>\n<tr>\n<td>Ruido<\/td>\n<td>&lt;58 dB a 1 m<\/td>\n<\/tr>\n<tr>\n<td>Comunicaci\u00f3n<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>SNMP<\/td>\n<td>Optional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>What Does 1\/1 Phase Mean in a UPS?<\/h2>\n<p>A 1\/1 phase UPS uses single-phase AC power at the input and supplies single-phase AC power at the output.<\/p>\n<p>This configuration is commonly used for critical single-phase loads in server rooms, telecom systems, medical equipment, security systems, financial infrastructure and industrial control applications.<\/p>\n<p>The DAXIN 1\/1 10K(L) uses this architecture for applications where both the facility supply and protected equipment require single-phase power.<\/p>\n<h2>Descripciones de productos y referencia t\u00e9cnica<\/h2>\n<figure class=\"wp-block-image size-full\"><figcaption>Product View for DAXIN 1\/1 10K(L) Low-Frequency 1\/1 Phase UPS.<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4900\" aria-describedby=\"caption-attachment-4900\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4900\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10KL-CS.png.webp\" alt=\"DAXIN 6kVA and 10kVA Single-Phase Online UPS Technical Specifications\" width=\"970\" height=\"901\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10KL-CS.png.webp 970w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10KL-CS.png-300x279.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10KL-CS.png-768x713.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/10KL-CS.png-13x12.webp 13w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><figcaption id=\"caption-attachment-4900\" class=\"wp-caption-text\">Technical specifications for DAXIN 6kVA and 10kVA single-phase online UPS models.<\/figcaption><\/figure><\/figure>\n<h2>Aplicaciones t\u00edpicas<\/h2>\n<ul data-start=\"6098\" data-end=\"6407\">\n<li data-section-id=\"150ngxp\" data-start=\"6098\" data-end=\"6129\">Server rooms and IT equipment<\/li>\n<li data-section-id=\"12pptsc\" data-start=\"6130\" data-end=\"6165\">Sistemas de telecomunicaciones y comunicaciones<\/li>\n<li data-section-id=\"18mpx12\" data-start=\"6166\" data-end=\"6211\">Industrial control and automation equipment<\/li>\n<li data-section-id=\"9i1azp\" data-start=\"6212\" data-end=\"6246\">Medical and diagnostic equipment<\/li>\n<li data-section-id=\"16dlkl6\" data-start=\"6247\" data-end=\"6278\">Banking and financial systems<\/li>\n<li data-section-id=\"vkt5qc\" data-start=\"6279\" data-end=\"6314\">Sistemas de seguridad y vigilancia<\/li>\n<li data-section-id=\"1jki8k0\" data-start=\"6315\" data-end=\"6360\">Transportation and infrastructure equipment<\/li>\n<li data-section-id=\"y5kyas\" data-start=\"6361\" data-end=\"6407\">Other critical single-phase electrical loads<\/li>\n<\/ul>\n<h2>How to Select the Right 10kVA Single-Phase UPS<\/h2>\n<p>Select the UPS according to the actual connected load in kW and kVA, input and output voltage, required backup time, battery configuration, startup or peak load, communication requirements and installation environment.<\/p>\n<p>For the DAXIN 1\/1 10K(L), confirm that the site provides the required single-phase input supply and that the protected equipment requires single-phase output.<\/p>\n<p>Provide DAXIN ENERGY with the load list, site voltage, required runtime, battery requirements, communication interfaces and installation conditions to determine the appropriate UPS configuration.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>\u00bfSe puede configurar este producto para un proyecto concreto?<\/h3>\n<p>S\u00ed. La configuraci\u00f3n el\u00e9ctrica, la autonom\u00eda de la bater\u00eda, las comunicaciones, el sistema de derivaci\u00f3n, la disposici\u00f3n de los armarios y los accesorios del proyecto pueden revisarse en funci\u00f3n de los requisitos de la instalaci\u00f3n.<\/p>\n<h3>\u00bfSe aplican todas las clasificaciones t\u00e9cnicas a toda la serie?<\/h3>\n<p>No. Las caracter\u00edsticas t\u00e9cnicas y las funciones var\u00edan seg\u00fan el modelo y la configuraci\u00f3n. Utilice la ficha t\u00e9cnica espec\u00edfica del proyecto como referencia definitiva.<\/p>\n<h3>\u00bfPuede DAXIN ENERGY ayudar en la selecci\u00f3n del sistema?<\/h3>\n<p>S\u00ed. Facilite la lista de cargas, la fase y la tensi\u00f3n, el tiempo de funcionamiento requerido, el objetivo de redundancia, los requisitos de comunicaci\u00f3n y el entorno de instalaci\u00f3n.<\/p>\n<h2>Solicitar una configuraci\u00f3n de proyecto<\/h2>\n<p>Env\u00edenos los datos de carga, el esquema unifilar, el tiempo de autonom\u00eda necesario y las condiciones del emplazamiento para recibir una propuesta personalizada de SAI o bater\u00edas.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1f7lrmo\" data-start=\"7961\" data-end=\"8016\">What is the rated capacity of the DAXIN 1\/1 10K(L)?<\/h3>\n<p data-start=\"8018\" data-end=\"8066\">The reference model is rated at 10kVA \/ 8kW.<\/p>\n<h3 data-section-id=\"1sji83t\" data-start=\"8068\" data-end=\"8097\">What does 1\/1 phase mean?<\/h3>\n<p data-start=\"8099\" data-end=\"8177\">It means the UPS uses single-phase input and provides single-phase output.<\/p>\n<h3 data-section-id=\"14q0qkz\" data-start=\"8179\" data-end=\"8232\">What is the transfer time during a power failure?<\/h3>\n<p data-start=\"8234\" data-end=\"8311\">The supplied reference specification lists 0ms mains-to-battery transfer.<\/p>\n<h3 data-section-id=\"1b2caab\" data-start=\"8313\" data-end=\"8358\">\u00bfQu\u00e9 tensi\u00f3n de salida admite el SAI?<\/h3>\n<p data-start=\"8360\" data-end=\"8443\">The reference configuration supports 208\/220\/230VAC output with \u00b11% regulation.<\/p>\n<h3 data-section-id=\"11q4njv\" data-start=\"8445\" data-end=\"8487\">Can the battery runtime be customized?<\/h3>\n<p data-start=\"8489\" data-end=\"8611\">Yes. Battery runtime depends on connected load, battery configuration, battery condition and required backup duration.<\/p>\n<h3 data-section-id=\"2u2uj0\" data-start=\"8613\" data-end=\"8656\">\u00bfEl SAI permite la supervisi\u00f3n remota?<\/h3>\n<p data-start=\"8658\" data-end=\"8763\">The reference configuration supports RS-232\/USB communication, with optional SNMP network management.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN 1\/1 10K(L) is a 10kVA\/8kW low-frequency online UPS designed for single-phase input and single-phase output critical power applications. Featuring 0ms transfer to battery operation, 208\/220\/230VAC output, configurable 16\/18-battery operation, RS-232\/USB communication and optional SNMP monitoring, it is suitable for control systems, telecom, healthcare, finance, transportation, security and other critical single-phase loads.<\/p>","protected":false},"featured_media":4901,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[107,99,97],"product_tag":[],"class_list":["post-2913","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-low-frequency-1-1-phase-ups","product_cat-low-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product\/2913","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/comments?post=2913"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media\/4901"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media?parent=2913"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_brand?post=2913"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_cat?post=2913"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_tag?post=2913"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}