{"id":2883,"date":"2026-08-02T15:14:28","date_gmt":"2026-08-02T15:14:28","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2883"},"modified":"2026-08-15T14:51:57","modified_gmt":"2026-08-15T06:51:57","slug":"daxin-hr33-10kl-hfrt-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/es\/product\/daxin-hr33-10kl-hfrt-ups\/","title":{"rendered":"SAI en l\u00ednea de 10 kVA para rack o torre | DAXIN HR33"},"content":{"rendered":"<h2>What Is the DAXIN HR33 10KL Rack\/Tower Online UPS?<\/h2>\n<p>The DAXIN HR33 10KL is a high-frequency online UPS designed to provide conditioned backup power for critical electrical and electronic equipment while supporting flexible rack or tower installation.<\/p>\n<p>Its rack\/tower convertible architecture allows the UPS to adapt to different equipment-room layouts, including rack-based IT environments and floor-standing installations.<\/p>\n<p>The HR33 10KL uses online double-conversion operation and supports digital control, LCD monitoring and project-configurable battery, communication, bypass and other system options according to the selected configuration.<\/p>\n<p>Typical applications include data centers, server rooms, telecom facilities, network infrastructure, professional electronics and other critical loads requiring reliable online power protection.<\/p>\n<h2>Ventajas principales<\/h2>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><strong>Rack\/Tower Convertible Design:<\/strong> Supports flexible installation in rack-based equipment rooms or tower configurations.<\/li>\n<li><strong>Online Double-Conversion Operation:<\/strong> Provides conditioned output power for connected critical loads.<\/li>\n<li><strong>High-Frequency UPS Architecture:<\/strong> Designed for professional critical-power applications with flexible deployment requirements.<\/li>\n<li><strong>Digital Control and LCD Monitoring:<\/strong> Supports convenient UPS status monitoring and system operation.<\/li>\n<li><strong>Configurable Battery Runtime:<\/strong> Battery configuration can be selected according to connected load and required backup duration.<\/li>\n<li><strong>Communication Options:<\/strong> Monitoring and communication interfaces can be configured according to project requirements.<\/li>\n<li><strong>Configuraci\u00f3n basada en proyectos:<\/strong> ECO, EPO, bypass, communications, parallel operation and other optional functions must be confirmed according to the selected configuration and approved technical specification.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2>What Is a Rack\/Tower Convertible UPS?<\/h2>\n<p>A rack\/tower convertible UPS is designed to support flexible installation in different equipment-room environments. Depending on the compatible mounting configuration, the UPS can be integrated into an equipment rack or deployed in a tower-style arrangement.<\/p>\n<p>This flexibility is useful for server rooms, data centers, telecom facilities and professional IT environments where available space and equipment layouts may vary.<\/p>\n<p>The DAXIN HR33 10KL applies this flexible installation concept to support different critical-power deployment requirements.<\/p>\n<h2>Why Use an Online Double-Conversion UPS?<\/h2>\n<p>An online double-conversion UPS continuously supplies connected loads through the inverter, providing conditioned output power for sensitive and critical equipment.<\/p>\n<p>This architecture is commonly used in applications where power continuity and output quality are important, including servers, network equipment, telecom systems and other professional electronic loads.<\/p>\n<p>The appropriate UPS capacity, battery runtime and system configuration should be selected according to the actual connected load and project requirements.<\/p>\n<h2>\nDescripciones de productos y referencia t\u00e9cnica<\/h2>\n<figure class=\"wp-block-image size-full\"><figcaption>Product View for DAXIN HR33 10KL High-Frequency Rack\/Tower Convertible UPS.<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4891\" aria-describedby=\"caption-attachment-4891\" style=\"width: 1181px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4891\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/HR33-10KL.webp\" alt=\"DAXIN HR33-10KL Online UPS Technical Specifications\" width=\"1181\" height=\"1332\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/HR33-10KL.webp 1181w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/HR33-10KL-266x300.webp 266w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/HR33-10KL-908x1024.webp 908w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/HR33-10KL-768x866.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/HR33-10KL-11x12.webp 11w\" sizes=\"auto, (max-width: 1181px) 100vw, 1181px\" \/><figcaption id=\"caption-attachment-4891\" class=\"wp-caption-text\">Technical specifications for the DAXIN HR33-10KL online UPS.<\/figcaption><\/figure><\/figure>\n<h2>Aplicaciones t\u00edpicas<\/h2>\n<ul>\n<li data-section-id=\"gdp63m\" data-start=\"5994\" data-end=\"6025\">Centros de datos y salas de servidores<\/li>\n<li data-section-id=\"19aqgp\" data-start=\"6026\" data-end=\"6064\">Telecom and communication facilities<\/li>\n<li data-section-id=\"1p7yz7d\" data-start=\"6065\" data-end=\"6114\">Network switches, servers and IT infrastructure<\/li>\n<li data-section-id=\"18mpx12\" data-start=\"6115\" data-end=\"6160\">Industrial control and automation equipment<\/li>\n<li data-section-id=\"jz16pb\" data-start=\"6161\" data-end=\"6194\">Sistemas de seguridad y vigilancia<\/li>\n<li data-section-id=\"550cqz\" data-start=\"6195\" data-end=\"6230\">Professional electronic equipment<\/li>\n<li data-section-id=\"hzn7qr\" data-start=\"6231\" data-end=\"6264\">Critical rack-mounted equipment<\/li>\n<li data-section-id=\"4r7z58\" data-start=\"6265\" data-end=\"6308\">Floor-mounted critical power applications<\/li>\n<\/ul>\n<h2>How to Select the Right 10kVA Rack\/Tower UPS<\/h2>\n<p>Select the UPS according to the actual connected load in kW and kVA, input and output phase, operating voltage, required backup time, battery configuration, installation orientation, bypass requirements and communication interfaces.<\/p>\n<p>For rack installations, confirm rack dimensions, available installation space, ventilation and service clearances. For tower installations, confirm floor space, airflow and maintenance access.<\/p>\n<p>Provide DAXIN ENERGY with the load list, site voltage, required runtime, rack or tower installation requirements, communication interfaces and installation environment to determine the appropriate UPS and battery configuration.<\/p>\n<h2>\nSelecci\u00f3n y planificaci\u00f3n del proyecto<\/h2>\n<p>Antes de realizar el pedido, compruebe que la potencia nominal exacta, la fase de entrada\/salida, la tensi\u00f3n, la frecuencia, el factor de potencia, la tensi\u00f3n de la bater\u00eda, el tiempo de autonom\u00eda, el modo de derivaci\u00f3n, las comunicaciones, las dimensiones, los l\u00edmites ambientales y el m\u00e9todo de instalaci\u00f3n se ajusten al modelo seleccionado y a los planos del proyecto.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>\u00bfSe puede configurar este producto para un proyecto concreto?<\/h3>\n<p>S\u00ed. La configuraci\u00f3n el\u00e9ctrica, la autonom\u00eda de la bater\u00eda, las comunicaciones, el sistema de derivaci\u00f3n, la disposici\u00f3n de los armarios y los accesorios del proyecto pueden revisarse en funci\u00f3n de los requisitos de la instalaci\u00f3n.<\/p>\n<h3>\u00bfSe aplican todas las clasificaciones t\u00e9cnicas a toda la serie?<\/h3>\n<p>No. Las caracter\u00edsticas t\u00e9cnicas y las funciones var\u00edan seg\u00fan el modelo y la configuraci\u00f3n. Utilice la ficha t\u00e9cnica espec\u00edfica del proyecto como referencia definitiva.<\/p>\n<h3>\u00bfPuede DAXIN ENERGY ayudar en la selecci\u00f3n del sistema?<\/h3>\n<p>S\u00ed. Facilite la lista de cargas, la fase y la tensi\u00f3n, el tiempo de funcionamiento requerido, el objetivo de redundancia, los requisitos de comunicaci\u00f3n y el entorno de instalaci\u00f3n.<\/p>\n<h2>Solicitar una configuraci\u00f3n de proyecto<\/h2>\n<p>Env\u00edenos los datos de carga, el esquema unifilar, el tiempo de autonom\u00eda necesario y las condiciones del emplazamiento para recibir una propuesta personalizada de SAI o bater\u00edas.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1vwsse4\" data-start=\"8753\" data-end=\"8821\">Can the HR33 10KL be installed in a rack or tower configuration?<\/h3>\n<blockquote data-start=\"8823\" data-end=\"8967\">\n<p data-start=\"8825\" data-end=\"8967\">The HR33 10KL is designed for flexible rack or tower installation according to the compatible mounting configuration and project requirements.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1p7xab4\" data-start=\"8969\" data-end=\"9022\">Is the HR33 10KL an online double-conversion UPS?<\/h3>\n<blockquote data-start=\"9024\" data-end=\"9130\">\n<p data-start=\"9026\" data-end=\"9130\">Yes. The product uses online double-conversion operation for conditioned critical-load power protection.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"11q4njv\" data-start=\"9132\" data-end=\"9174\">Can the battery runtime be customized?<\/h3>\n<blockquote data-start=\"9176\" data-end=\"9351\">\n<p data-start=\"9178\" data-end=\"9351\">Battery runtime depends on connected load, battery configuration and required backup duration. Long-runtime configurations can be reviewed according to project requirements.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1rfw13a\" data-start=\"9353\" data-end=\"9402\">Does the HR33 10KL support remote monitoring?<\/h3>\n<blockquote data-start=\"9404\" data-end=\"9564\">\n<p data-start=\"9406\" data-end=\"9564\">Communication and remote-monitoring options should be selected according to the HR33 10KL configuration and confirmed in the approved technical specification.<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>The DAXIN HR33 10KL is a high-frequency online UPS with flexible rack or tower installation for critical power applications. Featuring online double-conversion topology, digital control, LCD monitoring and configurable battery and communication options, it is designed for data centers, server rooms, telecom infrastructure, professional electronics and other critical loads. Final electrical ratings and optional functions are subject to the approved HR33 10KL technical configuration.<\/p>","protected":false},"featured_media":4892,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[106,98,97],"product_tag":[],"class_list":["post-2883","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-high-frequency-rack-tower-convertible-ups","product_cat-high-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product\/2883","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/comments?post=2883"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media\/4892"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media?parent=2883"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_brand?post=2883"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_cat?post=2883"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_tag?post=2883"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}