{"id":2260,"date":"2026-07-11T17:34:05","date_gmt":"2026-07-11T09:34:05","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=2260"},"modified":"2026-08-12T20:50:13","modified_gmt":"2026-08-12T12:50:13","slug":"180kva-three-phase-online-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/es\/product\/180kva-three-phase-online-ups\/","title":{"rendered":"SAI trif\u00e1sico en l\u00ednea de 180 kVA | DAXIN EX3C3"},"content":{"rendered":"<section class=\"daxin-customer-selection-guide\">\n<h2>What Is the DAXIN EX3C3 180kVA 3\/3 Phase Online UPS?<\/h2>\n<p>The DAXIN EX3C3 180kVA is a high-capacity three-phase input and three-phase output online UPS designed to protect mission-critical electrical and electronic loads.<\/p>\n<p>With online double-conversion topology, the UPS continuously supplies connected loads through the inverter, helping provide stable output during utility voltage fluctuations, frequency variations and power interruptions.<\/p>\n<p>The EX3C3 180kVA reference configuration provides 180kVA\/180kW rated capacity, 380\/400\/415VAC three-phase output, 0ms transfer time, greater than 96.5% efficiency and optional SNMP network management.<\/p>\n<p>Typical applications include data centers, industrial facilities, telecom infrastructure, healthcare systems, transportation infrastructure and other facilities requiring high-capacity three-phase power protection.<\/p>\n<h2>Qu\u00e9 hay que comprobar antes de realizar el pedido<\/h2>\n<ul>\n<li>Measured load and expansion allowance<\/li>\n<li>Required redundancy architecture<\/li>\n<li>Battery autonomy and room conditions<\/li>\n<li>Bypass, protection coordination and remote monitoring<\/li>\n<\/ul>\n<h2>Solicitar una configuraci\u00f3n de proyecto<\/h2>\n<p>Env\u00ede a DAXIN ENERGY la lista de cargas, la tensi\u00f3n de la instalaci\u00f3n, el tiempo de funcionamiento requerido, el entorno de instalaci\u00f3n y los requisitos de comunicaciones y redundancia. La configuraci\u00f3n definitiva estar\u00e1 sujeta a la propuesta t\u00e9cnica aprobada.<\/p>\n<\/section>\n<p><!-- DAXIN-HF-SEO-GEO-04-END --><\/p>\n<p><!-- DAXIN-HF-VIDEO-04-START --><\/p>\n<section class=\"daxin-product-video\">\n<h2>V\u00eddeo adicional sobre el SAI de alta frecuencia de DAXIN<\/h2>\n<p>Vea la demostraci\u00f3n del producto para conocer el formato del SAI, la interfaz de funcionamiento y el posicionamiento de la aplicaci\u00f3n. La configuraci\u00f3n el\u00e9ctrica definitiva estar\u00e1 sujeta a la propuesta t\u00e9cnica aprobada.<\/p>\n<div class=\"daxin-product-video-item\">\n<figure class=\"wp-block-video\"><video src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-high-frequency-ups-e5177d36f57b.mp4\" poster=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2260-gallery-01.webp?wsr\" preload=\"metadata\" controls=\"controls\" width=\"300\" height=\"150\">Su navegador no soporta la etiqueta de v\u00eddeo.<\/video><figcaption>Online UPS With Load Capacity 180KVA &#8211; Reliable Power Protection 99.999% Uptime Guarantee &#8211; DAXIN ENERGY.<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<p><!-- DAXIN-HF-VIDEO-04-END --><\/p>\n<h2>SAI en l\u00ednea trif\u00e1sico EX3C3 de 180 kVA<\/h2>\n<p>El SAI en l\u00ednea DAXIN ENERGY EX3C3 de 180 kVA est\u00e1 dise\u00f1ado para aplicaciones de respaldo de energ\u00eda cr\u00edticas a gran escala que requieren una alimentaci\u00f3n trif\u00e1sica fiable, alta eficiencia y un funcionamiento estable del sistema. Su topolog\u00eda en l\u00ednea de doble conversi\u00f3n ayuda a aislar los equipos sensibles de las fluctuaciones de la red el\u00e9ctrica, la inestabilidad de tensi\u00f3n, las variaciones de frecuencia, las interferencias arm\u00f3nicas y los cortes de suministro inesperados.<\/p>\n<h2>Caracter\u00edsticas principales<\/h2>\n<h3>Dise\u00f1o en l\u00ednea de doble conversi\u00f3n de alta fiabilidad<\/h3>\n<ul>\n<li>La aut\u00e9ntica topolog\u00eda de doble conversi\u00f3n en l\u00ednea proporciona una salida de onda sinusoidal pura para cargas cr\u00edticas.<\/li>\n<li>El seguimiento de la frecuencia de salida, el bloqueo de fase, la regulaci\u00f3n de tensi\u00f3n y el filtrado de ruido reducen el impacto de las fluctuaciones en la red el\u00e9ctrica.<\/li>\n<li>El control modular avanzado con doble CPU mejora la fiabilidad del sistema y la estabilidad de funcionamiento.<\/li>\n<li>El amplio rango de tensi\u00f3n de entrada de CA contribuye a reducir la descarga innecesaria de la bater\u00eda en entornos con un suministro el\u00e9ctrico deficiente.<\/li>\n<li>La funci\u00f3n de arranque en CC permite que el SAI se ponga en marcha directamente con la bater\u00eda cuando no hay suministro el\u00e9ctrico de la red.<\/li>\n<\/ul>\n<h3>Alta eficiencia y rendimiento compatible con la red el\u00e9ctrica<\/h3>\n<ul>\n<li>La tecnolog\u00eda PFC avanzada mantiene el factor de potencia de entrada cercano a 1.<\/li>\n<li>El dise\u00f1o del filtro de arm\u00f3nicos de entrada contribuye a reducir la contaminaci\u00f3n por retroalimentaci\u00f3n en la red el\u00e9ctrica.<\/li>\n<li>Los filtros arm\u00f3nicos de entrada y salida minimizan las interferencias arm\u00f3nicas provocadas por el sistema SAI.<\/li>\n<li>La tecnolog\u00eda de filtrado de alta frecuencia y sincronizaci\u00f3n mejora la compatibilidad con la energ\u00eda del generador.<\/li>\n<\/ul>\n<h3>Funciones de protecci\u00f3n completa<\/h3>\n<ul>\n<li>Protecci\u00f3n contra sobrecargas de salida.<\/li>\n<li>Protecci\u00f3n contra cortocircuitos en la salida.<\/li>\n<li>Protecci\u00f3n contra el sobrecalentamiento del inversor.<\/li>\n<li>Protecci\u00f3n contra el nivel bajo de tensi\u00f3n de la bater\u00eda.<\/li>\n<li>Protecci\u00f3n contra la sobrecarga de la bater\u00eda.<\/li>\n<li>El interruptor manual de derivaci\u00f3n para mantenimiento facilita las tareas de mantenimiento sin interrumpir el suministro el\u00e9ctrico a la carga.<\/li>\n<\/ul>\n<h3>Pantalla LCD y gesti\u00f3n inteligente<\/h3>\n<ul>\n<li>La pantalla LCD muestra en tiempo real el estado de funcionamiento del SAI, los par\u00e1metros del sistema y la informaci\u00f3n sobre alarmas.<\/li>\n<li>Las interfaces de comunicaci\u00f3n RS232 y RS485 permiten la supervisi\u00f3n local y la integraci\u00f3n en el sistema.<\/li>\n<li>El adaptador de red SNMP opcional permite la supervisi\u00f3n remota del SAI y la gesti\u00f3n centralizada de la alimentaci\u00f3n.<\/li>\n<li>Compatible con software inteligente de supervisi\u00f3n de SAI para obtener una visi\u00f3n clara de los datos de funcionamiento.<\/li>\n<\/ul>\n<h3>M\u00f3dulo opcional de monitorizaci\u00f3n inteligente de la bater\u00eda<\/h3>\n<ul>\n<li>Permite la detecci\u00f3n y supervisi\u00f3n de una sola bater\u00eda.<\/li>\n<li>Ofrece funciones de alarma por sobretensi\u00f3n, subtensi\u00f3n y diferencia de tensi\u00f3n.<\/li>\n<li>La informaci\u00f3n sobre fallos de la bater\u00eda puede mostrarse en la pantalla para ayudar a los administradores a reaccionar con rapidez.<\/li>\n<\/ul>\n<h3>Gran capacidad de adaptaci\u00f3n al entorno<\/h3>\n<p>Las placas de circuito impreso se instalan en una estructura totalmente cerrada y se tratan con un recubrimiento conformado, lo que mejora su fiabilidad en entornos adversos, como t\u00faneles, plazas, instalaciones industriales e infraestructuras.<\/p>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"5482\" data-end=\"5506\"><strong data-start=\"5482\" data-end=\"5506\">Aplicaciones t\u00edpicas<\/strong><\/p>\n<ul data-start=\"5508\" data-end=\"5899\">\n<li data-section-id=\"10h0a7k\" data-start=\"5508\" data-end=\"5550\">Large data centers and server facilities<\/li>\n<li data-section-id=\"dmzznz\" data-start=\"5551\" data-end=\"5599\">Industrial automation and manufacturing plants<\/li>\n<li data-section-id=\"1mn5mpb\" data-start=\"5600\" data-end=\"5652\">Telecom core networks and communication facilities<\/li>\n<li data-section-id=\"dk8qg1\" data-start=\"5653\" data-end=\"5703\">Hospitals and critical healthcare infrastructure<\/li>\n<li data-section-id=\"aiwgiw\" data-start=\"5704\" data-end=\"5756\">Transportation, tunnel and traffic-control systems<\/li>\n<li data-section-id=\"14xeilj\" data-start=\"5757\" data-end=\"5796\">Utility and infrastructure facilities<\/li>\n<li data-section-id=\"13izlhk\" data-start=\"5797\" data-end=\"5845\">Commercial buildings and large office campuses<\/li>\n<li data-section-id=\"1nqlak1\" data-start=\"5846\" data-end=\"5899\">Other mission-critical three-phase electrical loads<\/li>\n<\/ul>\n<h2>Especificaciones t\u00e9cnicas<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Modelo<\/th>\n<td>EX3C3-180 kVA<\/td>\n<\/tr>\n<tr>\n<th>Capacidad<\/th>\n<td>180 kVA \/ 180 kW<\/td>\n<\/tr>\n<tr>\n<th>Topolog\u00eda<\/th>\n<td>SAI de doble conversi\u00f3n en l\u00ednea<\/td>\n<\/tr>\n<tr>\n<th>Fase de entrada<\/th>\n<td>Trif\u00e1sico + neutro<\/td>\n<\/tr>\n<tr>\n<th>Rango de tensi\u00f3n de entrada<\/th>\n<td>110 V CA (fase-neutro) \u00b131 TP3T con una carga de 501 TP3T; 176 V CA (fase-neutro) \u00b131 TP3T con una carga de 1001 TP3T<\/td>\n<\/tr>\n<tr>\n<th>Frecuencia de entrada<\/th>\n<td>50\/60 Hz, selecci\u00f3n autom\u00e1tica<\/td>\n<\/tr>\n<tr>\n<th>Factor de potencia de entrada<\/th>\n<td>&gt; 0,99 con una carga de 100%<\/td>\n<\/tr>\n<tr>\n<th>Tensi\u00f3n de salida<\/th>\n<td>380 \/ 400 \/ 415 V CA, trif\u00e1sico<\/td>\n<\/tr>\n<tr>\n<th>Regulaci\u00f3n de la tensi\u00f3n de CA<\/th>\n<td>+\/-0.3%<\/td>\n<\/tr>\n<tr>\n<th>Frecuencia de salida<\/th>\n<td>46-54 Hz o 56-64 Hz en modo sincronizado; 50 Hz \u00b10,1 Hz o 60 Hz \u00b10,1 Hz en modo bater\u00eda<\/td>\n<\/tr>\n<tr>\n<th>Factor de cresta<\/th>\n<td>3:1<\/td>\n<\/tr>\n<tr>\n<th>Distorsi\u00f3n arm\u00f3nica total (THD) de salida<\/th>\n<td>&lt;=1% con carga lineal; &lt;=2% con carga no lineal<\/td>\n<\/tr>\n<tr>\n<th>Tiempo de transferencia<\/th>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<th>Eficiencia<\/th>\n<td>&gt; 96,51 TP3T en modo CA; &gt; 96,51 TP3T en modo bater\u00eda<\/td>\n<\/tr>\n<tr>\n<th>N\u00famero de bater\u00edas<\/th>\n<td>32-40 unidades, ajustable<\/td>\n<\/tr>\n<tr>\n<th>Corriente de carga<\/th>\n<td>3-54A \u00b1101 TP3T, preajuste 3 A<\/td>\n<\/tr>\n<tr>\n<th>Dimensiones<\/th>\n<td>1000 x 600 x 1200 mm<\/td>\n<\/tr>\n<tr>\n<th>Peso neto<\/th>\n<td>265 kg<\/td>\n<\/tr>\n<tr>\n<th>Temperatura de funcionamiento<\/th>\n<td>0-40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Humedad relativa<\/th>\n<td>&lt; 95%, sin condensaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<th>Ruido<\/th>\n<td>&lt; 75 dB a 1 m<\/td>\n<\/tr>\n<tr>\n<th>Comunicaci\u00f3n<\/th>\n<td>RS232 \/ RS485 \/ USB, SNMP opcional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure id=\"attachment_2264\" class=\"wp-caption aligncenter\" style=\"width: 2400px;\" aria-describedby=\"caption-attachment-2264\">\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1q38h4v\" data-start=\"7755\" data-end=\"7810\">Preguntas frecuentes:<br \/>\nWhat is the rated capacity of the EX3C3 180kVA UPS?<\/h3>\n<blockquote data-start=\"7812\" data-end=\"7882\">\n<p data-start=\"7814\" data-end=\"7882\">The EX3C3-180kVA reference configuration is rated at 180kVA \/ 180kW.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"98s6hi\" data-start=\"7884\" data-end=\"7924\">Is the EX3C3 180kVA a 3\/3 phase UPS?<\/h3>\n<blockquote data-start=\"7926\" data-end=\"8006\">\n<p data-start=\"7928\" data-end=\"8006\">Yes. It is designed for three-phase input and three-phase output applications.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1rytr2m\" data-start=\"8008\" data-end=\"8038\">What is the transfer time?<\/h3>\n<blockquote data-start=\"8040\" data-end=\"8133\">\n<p data-start=\"8042\" data-end=\"8133\">The reference specification lists 0ms transfer time for continuous online power protection.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"11oofti\" data-start=\"8135\" data-end=\"8187\">What output voltage does the 180kVA UPS support?<\/h3>\n<blockquote data-start=\"8189\" data-end=\"8262\">\n<p data-start=\"8191\" data-end=\"8262\">La configuraci\u00f3n de referencia admite una salida trif\u00e1sica de 380\/400\/415 V CA.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"dgnpvl\" data-start=\"8264\" data-end=\"8316\">Does the EX3C3 180kVA support remote monitoring?<\/h3>\n<blockquote data-start=\"8318\" data-end=\"8444\">\n<p data-start=\"8320\" data-end=\"8444\">Communication options include local interfaces and optional SNMP network management according to the selected configuration.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1g4jiu7\" data-start=\"8446\" data-end=\"8489\">How should battery runtime be selected?<\/h3>\n<blockquote data-start=\"8491\" data-end=\"8712\">\n<p data-start=\"8493\" data-end=\"8712\">Battery runtime depends on connected load, battery quantity and capacity, battery condition, temperature and required backup duration. DAXIN ENERGY can review the load and runtime requirements for project configuration.<\/p>\n<\/blockquote>\n<p><strong>What Is a 3\/3 Phase Online UPS?<\/strong><\/p>\n<p>A 3\/3 phase online UPS uses three-phase AC power at the input and supplies three-phase AC power at the output. This architecture is commonly used for high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and other large electrical installations.<\/p>\n<p>The DAXIN EX3C3 180kVA is designed for applications requiring high-capacity three-phase input and three-phase output power protection.<\/p>\n<p><figure id=\"attachment_4834\" aria-describedby=\"caption-attachment-4834\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4834\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs.webp\" alt=\"DAXIN EX3C3 10-200kVA 3\/3 Phase Online UPS Technical Specifications\" width=\"970\" height=\"958\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs.webp 970w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-300x296.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-768x758.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-12x12.webp 12w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-100x100.webp 100w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><figcaption id=\"caption-attachment-4834\" class=\"wp-caption-text\">Technical specifications for DAXIN EX3C3 10-200kVA 3\/3 phase online UPS series.<\/figcaption><\/figure><figcaption id=\"caption-attachment-2264\" class=\"wp-caption-text\">Especificaciones t\u00e9cnicas del SAI trif\u00e1sico en l\u00ednea de la serie EX3C3 de DAXIN ENERGY, incluido el modelo de 180 kVA.<\/figcaption><\/figure>\n<figure id=\"attachment_2223\" class=\"wp-caption aligncenter\" style=\"width: 1200px;\" aria-describedby=\"caption-attachment-2223\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2223\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2260-detail-02.webp\" alt=\"DAXIN ENERGY EX3C3 180kVA Three-Phase Online UPS technical detail 2 by DAXIN ENERGY\" width=\"1200\" height=\"631\" \/><figcaption id=\"caption-attachment-2223\" class=\"wp-caption-text\">Imagen para compartir en redes sociales del SAI en l\u00ednea DAXIN ENERGY 3H10kVA, dise\u00f1ado para centros de datos, salas de alimentaci\u00f3n de telecomunicaciones y sistemas de alimentaci\u00f3n de emergencia industriales.<\/figcaption><\/figure>","protected":false},"excerpt":{"rendered":"<p>The DAXIN EX3C3 180kVA is a high-capacity 3\/3 phase online UPS designed for critical power applications requiring three-phase input and three-phase output. Featuring online double-conversion topology, 0ms transfer, &gt;96.5% efficiency, intelligent battery management and optional SNMP monitoring, it provides stable power protection for data centers, industrial facilities, telecom infrastructure, healthcare and transportation systems.<\/p>","protected":false},"featured_media":4835,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[46,622],"product_cat":[98,104],"product_tag":[],"class_list":["post-2260","product","type-product","status-publish","has-post-thumbnail","product_brand-szdxzh","product_brand-daxin-energy","product_cat-high-frequency-ups","product_cat-hf-3-3-phase-ups","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product\/2260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/comments?post=2260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media\/4835"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media?parent=2260"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_brand?post=2260"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_cat?post=2260"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_tag?post=2260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}