{"id":160,"date":"2026-04-27T09:51:09","date_gmt":"2026-04-27T09:51:09","guid":{"rendered":"http:\/\/btrytech.com\/?post_type=product&#038;p=160"},"modified":"2026-04-27T10:22:07","modified_gmt":"2026-04-27T10:22:07","slug":"11-h1kva-standard-model-ups-product-promotion-materials-for-independent-station-overseas-oral-script","status":"publish","type":"product","link":"https:\/\/btrytech.com\/es\/product\/11-h1kva-standard-model-ups-product-promotion-materials-for-independent-station-overseas-oral-script\/","title":{"rendered":"11-H1kVA (Modelo est\u00e1ndar)--UPS Materiales de promoci\u00f3n de productos para estaciones independientes y guiones orales en el extranjero"},"content":{"rendered":"<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Power Capacity:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a01kVA<\/span><\/p>\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Operating Mode:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Single-phase input \/ Single-phase output, True Online Double-conversion.<\/span><\/p>\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Applications:<\/span><\/strong><br class=\"ng-star-inserted\" \/><span class=\"ng-star-inserted\">Widely applied across various sectors including government, finance, telecommunications, education, transportation, meteorology, broadcasting, commerce and taxation, healthcare, energy, and utilities.<\/span><\/p>\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Product Features:<\/span><\/strong><\/p>\n<ul class=\"ng-star-inserted\">\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">True online double-conversion:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Ensures seamless power protection.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Microprocessor control:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Guarantees high reliability and precision.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Input Power Factor Correction (PFC):<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Optimizes energy efficiency from the grid.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">High Output Power Factor:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Up to 0.9 for better load compatibility.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Wide Input Voltage Range (90V \u2013 300V):<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Ideal for unstable power environments.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Frequency Converter Mode:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Highly efficient frequency conversion options.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Generator Compatible:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Works effectively with various generator sets.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Advanced Monitoring:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Optional SNMP card works seamlessly with USB or RS232 for comprehensive remote management.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">User-friendly Display:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Simple operation and control via the integrated display for real-time UPS status monitoring.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">ECO Mode:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Provides high-efficiency operation for energy saving.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Emergency Power Off (EPO):<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Enhances safety for critical installations.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">DSP Technology:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0This series utilizes advanced Digital Signal Processing; includes a built-in maintenance bypass switch (optional).<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Smart Battery Charger Design:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Optimized to extend battery life and maximize performance.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Built-in Isolation Transformer (Optional):<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Provides additional electrical safety and noise suppression.<\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Technical Specifications<br \/>\n<\/span><\/strong><\/p>\n<table style=\"height: 2152px;\" width=\"1357\">\n<thead>\n<tr>\n<th>Item<\/th>\n<th>11-H1kVA<\/th>\n<th>11-H2kVA<\/th>\n<th>11-H3kVA<\/th>\n<th>11-H6kVA<\/th>\n<th>11-H10kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Capacity<\/strong><\/td>\n<td>1000VA\/900W<\/td>\n<td>2000VA\/1800W<\/td>\n<td>3000VA\/2700W<\/td>\n<td>6000VA\/5400W<\/td>\n<td>10000VA\/9000W<\/td>\n<\/tr>\n<tr>\n<td>### Input<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>Single-phase grounded<\/td>\n<td>Single-phase grounded<\/td>\n<td>Single-phase grounded<\/td>\n<td>Single-phase grounded<\/td>\n<td>Single-phase grounded<\/td>\n<\/tr>\n<tr>\n<td>Minimum Transfer Voltage<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>160VAC\/140VAC\/120VAC\/110VAC \u00b15% (Ambient temp \uff1c35\u2103; Load ratio: 100%-80%-80%-70%-70%-70%-60%-60%-0)<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>50% load: 110VAC \u00b13%;<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>100% load: 176VAC \u00b13%<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Minimum Restore Voltage<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>195VAC\/175VAC\/155VAC\/135VAC \u00b15% (Ambient temp \uff1c35\u2103; Load ratio: 100%-80%-80%-70%-70%-60%-60%-0)<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>Minimum transfer voltage +10V<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Maximum Transfer Voltage<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>300VAC \u00b15%<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>300VAC \u00b13%<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Maximum Restore Voltage<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>290VAC \u00b15%<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>Maximum transfer voltage -10V<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Frequency Range<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>40Hz ~ 70Hz<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>46Hz~54Hz (@50Hz system);<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>56Hz~64Hz (@60Hz system)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Power Factor<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>\u22650.99 @ 220-230-240VAC (input voltage)<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>N\/A<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>### Output<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Output Voltage<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>208\/220\/230\/240VAC \u00b11%<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>208\/220\/230\/240VAC \u00b11%<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Frequency Range (Sync Correction)<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>47-53Hz or 57-63Hz<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>46-54Hz or 56-64Hz<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Frequency Range (Battery Mode)<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>50\u00b10.25Hz or 60\u00b10.3Hz<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>50\u00b10.1Hz or 60\u00b10.1Hz<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Crest Factor<\/td>\n<td>colspan=&#8221;5&#8243;<\/td>\n<td>3:1<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Total Harmonic Distortion (THD)<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>\u22643% THD (linear load); \u22646% THD (non-linear load)<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>\u22643% THD (linear load); \u22645% THD (non-linear load)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Overload Capability<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>Temp\uff1c35\u2103:<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>105%-110%: UPS auto-restarts in 10s after fault; recovers output within 1s when input normalizes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>110%-130%: UPS auto-shuts down after 3 mins; recovers output after 3s when input normalizes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>\uff1e150%: UPS instant shutdown<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>100%~110%: 30 minutes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>110%~130%: 5 minutes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>\uff1e130%: 10 seconds<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Transfer Time: Mains to Battery<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>0ms<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>0ms<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Transfer Time: Inverter to Bypass<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>4ms (standard condition)<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>0ms<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Waveform (Battery Mode)<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>Pure Sine Wave<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>N\/A<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>### Efficiency<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Mains Mode<\/td>\n<td>88%<\/td>\n<td>89%<\/td>\n<td>90%<\/td>\n<td>92%<\/td>\n<td>93%<\/td>\n<\/tr>\n<tr>\n<td>Battery Mode<\/td>\n<td>83%<\/td>\n<td>87%<\/td>\n<td>88%<\/td>\n<td>90%<\/td>\n<td>91%<\/td>\n<\/tr>\n<tr>\n<td>### Battery<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Standard Unit (S)<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Battery Type<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>12V\/7Ah<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>12V\/7Ah<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Battery Quantity<\/td>\n<td>2<\/td>\n<td>4<\/td>\n<td>6<\/td>\n<td>12<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>Charging Current<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>1.0A<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>Preset: 1.0A \u00b110%, Max: 1A\/2A<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Long-Run Unit (L)<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Battery Type<\/td>\n<td>colspan=&#8221;5&#8243;<\/td>\n<td>12V\/AH (Customized per purchaser requirement)<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Battery Quantity<\/td>\n<td>3<\/td>\n<td>3<\/td>\n<td>8<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>Model-dependent<\/td>\n<\/tr>\n<tr>\n<td>Charging Current<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>1A\/2A\/4A\/6A<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>1A\/2A\/4A\/6A (adjustable);<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>6A only applicable for 16-cell battery pack<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>### Physical Specifications<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><strong>Standard Unit<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Dimension: D\u00d7W\u00d7H (mm)<\/td>\n<td>282\u00d7145\u00d7220<\/td>\n<td>397\u00d7145\u00d7220<\/td>\n<td>421\u00d7190\u00d7318<\/td>\n<td>369\u00d7190\u00d7688<\/td>\n<td>442\u00d7190\u00d7688<\/td>\n<\/tr>\n<tr>\n<td>Net Weight (kg)<\/td>\n<td>9.8<\/td>\n<td>17<\/td>\n<td>26.2<\/td>\n<td>51<\/td>\n<td>55<\/td>\n<\/tr>\n<tr>\n<td><strong>Long-Run Unit<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Dimension: D\u00d7W\u00d7H (mm)<\/td>\n<td>282\u00d7145\u00d7220<\/td>\n<td>397\u00d7145\u00d7220<\/td>\n<td>421\u00d7190\u00d7318<\/td>\n<td>369\u00d7190\u00d7318<\/td>\n<td>442\u00d7190\u00d7318<\/td>\n<\/tr>\n<tr>\n<td>Net Weight (kg)<\/td>\n<td>4.4<\/td>\n<td>6.8<\/td>\n<td>7.4<\/td>\n<td>12<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<td>### Operating Environment<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Operating Humidity<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>20-90% RH, 0-40\u2103 (non-condensing)<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>\uff1c95% RH, non-condensing<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Noise<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>\uff1c50dB @ 1 meter<\/td>\n<td>\uff1c55dB @ 1 meter<\/td>\n<td>\uff1c58dB @ 1 meter<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td>colspan=&#8221;3&#8243;<\/td>\n<td>N\/A<\/td>\n<td>colspan=&#8221;2&#8243;<\/td>\n<td>0 ~ 40\u2103 (Battery life shortened above 25\u2103 ambient temp)<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>### Control &amp; Management<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Intelligent RS-232\/USB<\/td>\n<td>colspan=&#8221;5&#8243;<\/td>\n<td>Compatible with Windows 2000\/2003\/XP\/Vista\/2008, Windows7\/8, Linux &amp; MAC systems<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Optional SNMP Card<\/td>\n<td>colspan=&#8221;5&#8243;<\/td>\n<td>Supports SNMP network management &amp; remote monitoring<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul class=\"ng-star-inserted\">\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">For 1-3kVA UPS:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Output power capacity will be\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">derated to 80%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0when the UPS is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">CVCF mode<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0(Constant Voltage Constant Frequency) or when the output voltage is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">208VAC<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">For 6\/10kVA UPS:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Output power capacity will be\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">derated to 60%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0when the UPS is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">CVCF mode<\/span><\/strong><span class=\"ng-star-inserted\">, and\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">derated to 90%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0when the output voltage is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">208VAC<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Parallel Redundancy:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0The standard models listed above do not support\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">redundant parallel operation<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Voltage Compatibility:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Output voltage settings of 200\/208\/220\/230\/240VAC are only applicable to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">long-run models<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<\/ul>\n<p class=\"ng-star-inserted\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-179 size-full\" src=\"http:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1.jpg\" alt=\"\" width=\"925\" height=\"591\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1.jpg 925w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1-600x383.jpg 600w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1-300x192.jpg 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1-768x491.jpg 768w\" sizes=\"auto, (max-width: 925px) 100vw, 925px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<div data-page-id=\"P3CHfwooWdRAPocIHvXcT4MSnGg\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\">\n<div class=\"ace-line ace-line old-record-id-SzU1fvxCud5f2lcpNBhcSWRqnPb\">Our 1kVA-10kVA UPS series features true online double-conversion technology, ensuring seamless power protection for your critical equipment. With a wide input voltage range (90V-300V), microprocessor control, and PFC optimization, it delivers high reliability, energy efficiency, and load compatibility (up to 0.9 output power factor). Suitable for government, finance, telecommunications, education, healthcare, energy, and other key sectors, this UPS supports optional SNMP remote monitoring, ECO mode for energy saving, and smart battery design to extend service life\u2014keeping your operations running smoothly even in unstable power environments.<\/div>\n<\/div>","protected":false},"featured_media":169,"comment_status":"open","ping_status":"closed","template":"","meta":{"_crdt_document":""},"product_brand":[46],"product_cat":[102,98,97],"product_tag":[111,115,113,116,114,110,112],"class_list":["post-160","product","type-product","status-publish","has-post-thumbnail","product_brand-szdxzh","product_cat-hf-1-1-phase-ups","product_cat-high-frequency-ups","product_cat-ups-solutions","product_tag-1kva-10kva-ups","product_tag-eco-mode-ups","product_tag-pfc-ups","product_tag-smart-battery-ups","product_tag-snmp-remote-monitoring-ups","product_tag-true-online-double-conversion-ups","product_tag-wide-input-voltage-ups-90v-300v","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product\/160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/comments?post=160"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media\/169"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/media?parent=160"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_brand?post=160"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_cat?post=160"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/es\/wp-json\/wp\/v2\/product_tag?post=160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}