{"id":4712,"date":"2026-08-09T18:57:20","date_gmt":"2026-08-09T10:57:20","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=4712"},"modified":"2026-08-09T18:57:21","modified_gmt":"2026-08-09T10:57:21","slug":"3h15kva-online-ups-system","status":"publish","type":"product","link":"https:\/\/btrytech.com\/en\/product\/3h15kva-online-ups-system\/","title":{"rendered":"3H15kVA Online UPS System | Three Phase Double Conversion UPS"},"content":{"rendered":"<p><strong>\u4e00\u3001Product Overview\uff1a<\/strong><br \/>\nThe 3H15kVA Online UPS System is a high-performance three-phase uninterruptible power supply designed for applications requiring continuous, stable, and clean power.<\/p>\n<p>With true online double conversion technology, MCU + DSP digital control, flexible battery configuration, and intelligent monitoring capabilities, this UPS ensures reliable power protection for data centers, industrial equipment, communicatio<br \/>\n<strong>\u4e8c\u3001Key Features\uff1a<\/strong><br \/>\n1. True Online Double Conversion Technology\uff1a<br \/>\nThe UPS continuously converts AC input power into stable DC power and then converts it back into clean AC output.<\/p>\n<p>This design effectively protects connected equipment from:<\/p>\n<p>Voltage fluctuations<br \/>\nFrequency variations<br \/>\nPower interruptions<br \/>\nElectrical disturbances<br \/>\n2. Generator Compatible Operation\uff1a<br \/>\nThe 3H15kVA UPS supports generator input connection.<\/p>\n<p>For stable operation, the recommended generator capacity should be at least 2 times the UPS<br \/>\n<strong>rated capacity\uff1a<\/strong><br \/>\n\u00b7Remote areas<br \/>\n\u00b7Industrial sites<br \/>\n\u00b7Backup power systems<\/p>\n<p><strong>3. Flexible System Configuration<\/strong><br \/>\nThe system supports flexible configuration according to different application requirements:<\/p>\n<p>\u00b7Optional output isolation transforme<br \/>\n\u00b7Adjustable battery quantity: 16-20 battery units<br \/>\n\u00b7Adjustable charging current: 1-4A<br \/>\n\u00b7PF0.8 \/ PF0.9 power factor options<br \/>\n\u00b7Automatic restart after mains recovery<\/p>\n<p><strong>4. Parallel Expansion Capability<\/strong><br \/>\nSelected models support parallel operation with up to 3 UPS units, allowing higher capacity expansion and improved system redundancy.<\/p>\n<p><strong>5. Comprehensive Protection System<\/strong><br \/>\nThe UPS integrates multiple protection functions to ensure safe and reliable operation:<\/p>\n<p>Protection includes:<\/p>\n<p>\u00b7Output overload protection<br \/>\n\u00b7Output short circuit protection<br \/>\n\u00b7Inverter over-temperature protection<br \/>\n\u00b7Battery undervoltage warning<br \/>\n\u00b7Battery overcharge protection<\/p>\n<p><strong>6. Intelligent Interface and Monitoring Management<\/strong><\/p>\n<p>The LCD display provides real-time information including:<\/p>\n<p>UPS operating status<br \/>\nInput\/output parameters<br \/>\nBattery information<br \/>\nAlarm records<\/p>\n<p>Communication interfaces:<\/p>\n<p>RS232<br \/>\nRS485<br \/>\nSNMP network adapter<\/p>\n<p>The UPS monitoring software enables remote management through computer systems.<\/p>\n<p><strong>7. High Environmental Adaptability<\/strong><\/p>\n<p>The internal circuit boards are installed in a fully enclosed structure and treated with conformal coating technology.<\/p>\n<p>This improves resistance against harsh environments such as:<\/p>\n<p>Dust<br \/>\nMoisture<br \/>\nIndustrial pollution<\/p>\n<p>Suitable for:<\/p>\n<p>Tunnels<br \/>\nIndustrial facilities<br \/>\nOutdoor infrastructure<\/p>\n<p><strong>\u4e09\u3001Technical Specifications\uff1a<br \/>\n<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Item<\/th>\n<th><\/th>\n<th>3H10kVA<\/th>\n<th>3H15kVA<\/th>\n<th>3H20kVA<\/th>\n<th>3H30kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Input<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td><\/td>\n<td>3\u2011phase with neutral grounded<\/td>\n<td>3\u2011phase with neutral grounded<\/td>\n<td>3\u2011phase with neutral grounded<\/td>\n<td>3\u2011phase grounded<\/td>\n<\/tr>\n<tr>\n<td>Voltage Range<\/td>\n<td>Lowest transfer voltage @3%<\/td>\n<td>50% load:110VAC \u00b13%;100% load:176VAC \u00b13%<\/td>\n<td>50% load:110VAC \u00b13%;100% load:176VAC \u00b13%<\/td>\n<td>50% load:110VAC \u00b13%;100% load:176VAC \u00b13%<\/td>\n<td>50% load:110VAC \u00b13%;100% load:176VAC \u00b13%<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Lowest restore voltage<\/td>\n<td>Min.transfer voltage +10V<\/td>\n<td>Min.transfer voltage +10V<\/td>\n<td>Min.transfer voltage +10V<\/td>\n<td>Min.transfer voltage +10V<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Highest transfer voltage @\u20113%<\/td>\n<td>300VAC \u00b13%<\/td>\n<td>300VAC \u00b13%<\/td>\n<td>300VAC \u00b13%<\/td>\n<td>300VAC \u00b13%<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Highest restore voltage<\/td>\n<td>Max.transfer voltage\u201110V<\/td>\n<td>Max.transfer voltage\u201110V<\/td>\n<td>Max.transfer voltage\u201110V<\/td>\n<td>Max.transfer voltage\u201110V<\/td>\n<\/tr>\n<tr>\n<td>Frequency Range<\/td>\n<td><\/td>\n<td>46\u201154Hz@50Hz System; 56\u201164Hz@60Hz System<\/td>\n<td>46\u201154Hz@50Hz System; 56\u201164Hz@60Hz System<\/td>\n<td>46\u201154Hz@50Hz System; 56\u201164Hz@60Hz System<\/td>\n<td>46\u201154Hz@50Hz System; 56\u201164Hz@60Hz System<\/td>\n<\/tr>\n<tr>\n<td>Power Factor<\/td>\n<td><\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>\u22650.99 at 100% Load<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Output<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Output Voltage<\/td>\n<td><\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<\/tr>\n<tr>\n<td>AC Voltage Range<\/td>\n<td><\/td>\n<td>\u00b11%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b11%<\/td>\n<td>\u00b11%<\/td>\n<\/tr>\n<tr>\n<td>Frequency Range(Sync Range)<\/td>\n<td><\/td>\n<td>46\u201154Hz@50Hz; 56\u201164Hz@60Hz System<\/td>\n<td>46\u201154Hz@50Hz; 56\u201164Hz@60Hz System<\/td>\n<td>46\u201154Hz@50Hz; 56\u201164Hz@60Hz System<\/td>\n<td>46\u201154Hz@50Hz; 56\u201164Hz@60Hz System<\/td>\n<\/tr>\n<tr>\n<td>Frequency Range(Battery Mode)<\/td>\n<td><\/td>\n<td>50Hz\u00b10.1Hz or 60Hz\u00b10.1Hz<\/td>\n<td>50Hz\u00b10.1Hz or 60Hz\u00b10.1Hz<\/td>\n<td>50Hz\u00b10.1Hz or 60Hz\u00b10.1Hz<\/td>\n<td>50Hz\u00b10.1Hz or 60Hz\u00b10.1Hz<\/td>\n<\/tr>\n<tr>\n<td>Current Crest Factor<\/td>\n<td><\/td>\n<td>3:1(max)<\/td>\n<td>3:1(max)<\/td>\n<td>3:1(max)<\/td>\n<td>3:1(max)<\/td>\n<\/tr>\n<tr>\n<td>THD\u2011Total Harmonic Distortion<\/td>\n<td><\/td>\n<td>\u22643% THD(Linear Load); \u22645% THD(Non\u2011linear Load)<\/td>\n<td>\u22643% THD(Linear Load); \u22645% THD(Non\u2011linear Load)<\/td>\n<td>\u22643% THD(Linear Load); \u22645% THD(Non\u2011linear Load)<\/td>\n<td>\u22642% THD(Linear Load); \u22645% THD(Non\u2011linear Load)<\/td>\n<\/tr>\n<tr>\n<td>Transfer Time<\/td>\n<td>Mains to Battery<\/td>\n<td>0ms<\/td>\n<td>0ms<\/td>\n<td>0ms<\/td>\n<td>0ms<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Inverter to Bypass<\/td>\n<td>0ms<\/td>\n<td>0ms<\/td>\n<td>0ms<\/td>\n<td>0ms<\/td>\n<\/tr>\n<tr>\n<td>Overload<\/td>\n<td><\/td>\n<td>100%\u2011110%:30min<\/p>\n<div><\/div>\n<p>110%\u2011130%:5min<\/p>\n<div><\/div>\n<p>&gt;130%:1s<\/td>\n<td>100%\u2011110%:15min<\/p>\n<div><\/div>\n<p>110%\u2011130%:30s<\/p>\n<div><\/div>\n<p>&gt;130%:1s<\/td>\n<td>100%\u2011110%:5min<\/p>\n<div><\/div>\n<p>110%\u2011130%:1s<\/p>\n<div><\/div>\n<p>&gt;130%:Immediate Trip<\/td>\n<td>100%\u2011110%:10min<\/p>\n<div><\/div>\n<p>110%\u2011130%:1min<\/p>\n<div><\/div>\n<p>&gt;130%:1s<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Efficiency<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>AC Mode<\/td>\n<td><\/td>\n<td>\uff1e91%<\/td>\n<td>\uff1e91%<\/td>\n<td>\uff1e91%<\/td>\n<td>\uff1e90%<\/td>\n<\/tr>\n<tr>\n<td>Battery Mode<\/td>\n<td><\/td>\n<td>\uff1e91%<\/td>\n<td>\uff1e91%<\/td>\n<td>\uff1e91%<\/td>\n<td>\uff1e88%<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Battery<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Long\u2011run Model<\/td>\n<td>Model<\/td>\n<td>12V, subject to application<\/td>\n<td>12V, subject to application<\/td>\n<td>12V, subject to application<\/td>\n<td>12V, subject to application<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Quantity<\/td>\n<td>16\u201120 pcs<\/td>\n<td>16\u201120 pcs<\/td>\n<td>16\u201120 pcs<\/td>\n<td>18\u201120 pcs<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>Charging Current<\/td>\n<td>Preset:4A \u00b110%; Max:1A,2A,4A optional<\/td>\n<td>Preset:4A \u00b110%; Max:1A,2A,4A optional<\/td>\n<td>Preset:4A \u00b110%; Max:1A,2A,4A optional<\/td>\n<td>12A \u00b110%<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Physical Properties<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Dimension(Depth\u00d7Width\u00d7Height) mm<\/td>\n<td><\/td>\n<td>442 \u00d7 190 \u00d7 318<\/td>\n<td>592 \u00d7 250 \u00d7 576<\/td>\n<td><\/td>\n<td>910 \u00d7 380 \u00d7 910<\/td>\n<\/tr>\n<tr>\n<td>Long\u2011run Model Net Weight (kg)<\/td>\n<td><\/td>\n<td>15<\/td>\n<td>24.5<\/td>\n<td>28.5<\/td>\n<td>67.3<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Operating Environment<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td><\/td>\n<td>0\uff5e50\u2103(Battery life shortens above 25\u2103)<\/td>\n<td>0\uff5e50\u2103(Battery life shortens above 25\u2103)<\/td>\n<td>0\uff5e50\u2103(Battery life shortens above 25\u2103)<\/td>\n<td>0\uff5e40\u2103(Battery life shortens above 25\u2103)<\/td>\n<\/tr>\n<tr>\n<td>Relative Humidity<\/td>\n<td><\/td>\n<td>\uff1c95% non\u2011condensing<\/td>\n<td>\uff1c95% non\u2011condensing<\/td>\n<td>\uff1c95% non\u2011condensing<\/td>\n<td>\uff1c95% non\u2011condensing<\/td>\n<\/tr>\n<tr>\n<td>Max.Operating Altitude<\/td>\n<td><\/td>\n<td>\uff1c1000m<\/td>\n<td>\uff1c1000m<\/td>\n<td>\uff1c1000m<\/td>\n<td>\uff1c1000m<\/td>\n<\/tr>\n<tr>\n<td>Noise<\/td>\n<td><\/td>\n<td>\uff1c60dB@1 Meter<\/td>\n<td>\uff1c60dB@1 Meter<\/td>\n<td>\uff1c60dB@1 Meter<\/td>\n<td>\uff1c65dB@1 Meter<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Control &amp; Management<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Intelligent RS\u2011232 \/ USB<\/td>\n<td><\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008, Windows\u00ae7\/8, Linux, Unix, MAC OS<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008, Windows\u00ae7\/8, Linux, Unix, MAC OS<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008, Windows\u00ae7\/8, Linux, Unix, MAC OS<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008, Windows\u00ae7\/8, Linux, Unix, MAC OS<\/td>\n<\/tr>\n<tr>\n<td>Optional SNMP<\/td>\n<td><\/td>\n<td>Support power management via SNMP &amp; Network Management<\/td>\n<td>Support power management via SNMP &amp; Network Management<\/td>\n<td>Support power management via SNMP &amp; Network Management<\/td>\n<td>Support power management via SNMP &amp; Network Management<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Footnotes<\/strong><br \/>\n* In CVCF mode, output power will derate to 60%; When output voltage is set to 208VAC, output power will derate to 80%.<br \/>\n** If UPS is installed at altitude above 1000\u202fm, output power shall be derated by 1% for every additional 100\u202fm.<br \/>\n*** Specifications subject to change without prior notice.<\/p>\n<p><strong>\u56db\u3001Application Applications<\/strong><br \/>\nThe 3H15kVA UPS is suitable for:<\/p>\n<p><strong>Data Centers<\/strong><\/p>\n<p>Protect servers, network equipment, and IT infrastructure from power interruptions.<\/p>\n<p><strong>Industrial Automation<\/strong><\/p>\n<p>Provide stable power for manufacturing equipment and control systems.<\/p>\n<p><strong>Telecom Infrastructure<\/strong><\/p>\n<p>Ensure continuous operation of communication equipment.<\/p>\n<p><strong>Critical Facilities<\/strong><\/p>\n<p>Suitable for hospitals, security systems, and other important electrical applications.<\/p>\n<p><strong>\u4e94\u3001FAQ<\/strong><br \/>\n<strong>Q1: What is a 3H15kVA Online UPS System?<\/strong><br \/>\nA 3H15kVA Online UPS System is a three-phase uninterruptible power supply that provides continuous power protection through true online double conversion technology.<\/p>\n<p><strong>Q2: Does the 3H15kVA UPS support generator input?<\/strong><br \/>\nYes. The UPS supports generator input. The recommended generator capacity should be at least twice the UPS rated capacity.<\/p>\n<p><strong>Q3: How many batteries can be configured?<\/strong><br \/>\nThe battery configuration can be adjusted from 16 to 20 battery units according to customer requirements.<\/p>\n<p><strong>Q4: Does the UPS support parallel operation?<\/strong><br \/>\nYes. Selected models support up to three UPS units operating in parallel.<\/p>\n<p><strong>Q5: Where can this UPS be used?<\/strong><br \/>\nThe UPS is widely used in data centers, industrial facilities, telecom systems, and other applications requiring high power reliability.<\/p>\n<p><strong>Q6: What are the advantages of a true online double conversion UPS?<\/strong><br \/>\nA true online double conversion UPS provides continuous power conditioning by isolating connected equipment from voltage fluctuations, frequency variations, and electrical disturbances.<\/p>\n<p><strong>Q7: What is the recommended application for a 15kVA UPS system?<\/strong><br \/>\nA 15kVA UPS system is commonly used for small and medium-sized data centers, industrial automation systems, telecom equipment rooms, and other critical power environments.<\/p>\n<figure id=\"attachment_4072\" aria-describedby=\"caption-attachment-4072\" style=\"width: 982px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4072\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2292-detail-01.webp\" alt=\"30kVA Three-Phase Online UPS | DAXIN ENERGY EX3C3 technical detail 1 by DAXIN ENERGY\" width=\"982\" height=\"664\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2292-detail-01.webp 982w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2292-detail-01-300x203.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2292-detail-01-768x519.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2292-detail-01-18x12.webp 18w\" sizes=\"auto, (max-width: 982px) 100vw, 982px\" \/><figcaption id=\"caption-attachment-4072\" class=\"wp-caption-text\">30kVA Three-Phase Online UPS | DAXIN ENERGY EX3C3 \u2014 DAXIN ENERGY technical detail 1.<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>The 3H15kVA Online UPS System is a reliable three-phase uninterruptible power supply designed to provide continuous and stable power protection for critical applications.<\/p>\n<p>Featuring true online double conversion technology, MCU + DSP digital control, flexible battery configuration, and intelligent monitoring management, this high reliability UPS system delivers clean power for data centers, industrial equipment, telecom infrastructure, and other mission-critical facilities.<\/p>\n","protected":false},"featured_media":4713,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,103],"product_tag":[],"class_list":["post-4712","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-hf-3-1-phase-ups","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product\/4712","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/comments?post=4712"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/media\/4713"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/media?parent=4712"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_brand?post=4712"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_cat?post=4712"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_tag?post=4712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}