{"id":2845,"date":"2026-08-02T23:09:32","date_gmt":"2026-08-02T15:09:32","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2845"},"modified":"2026-08-12T11:51:57","modified_gmt":"2026-08-12T03:51:57","slug":"high-frequency-rack-mount-online-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/en\/product\/high-frequency-rack-mount-online-ups\/","title":{"rendered":"High-Frequency Rack-Mount Online UPS 1-10kVA | DAXIN"},"content":{"rendered":"<p><!-- DAXIN-HF-SEO-GEO-04-START --><\/p>\n<section class=\"daxin-customer-selection-guide\">\n<h2>Is This UPS Right for Your Project?<\/h2>\n<p>The DAXIN 1kVA rack-mount online UPS provides compact double-conversion protection for 19-inch rack equipment, network devices and small server installations.<\/p>\n<p>Its rack format preserves floor space and places protected power close to the supported IT or communications equipment.<\/p>\n<h2>Typical Applications<\/h2>\n<ul>\n<li>Network racks and edge servers<\/li>\n<li>Security and surveillance systems<\/li>\n<li>Telecom equipment<\/li>\n<li>Laboratory and control racks<\/li>\n<\/ul>\n<h2>What to Confirm Before Ordering<\/h2>\n<ul>\n<li>Rack depth and available U space<\/li>\n<li>Load in watts and power factor<\/li>\n<li>Standard battery or extended runtime<\/li>\n<li>Input plug, output sockets and monitoring interface<\/li>\n<\/ul>\n<h2>Frequently Asked Questions<\/h2>\n<h3>How should I choose the UPS capacity?<\/h3>\n<p>Start with the measured continuous load, startup or peak demand and expected expansion. DAXIN ENERGY can review the load list and recommend a practical operating margin.<\/p>\n<h3>How is battery runtime determined?<\/h3>\n<p>Runtime depends on load, battery voltage, battery capacity, battery age, temperature and inverter efficiency. Share the required backup duration and normal load for a project calculation.<\/p>\n<h3>Can this UPS work with a generator or remote monitoring system?<\/h3>\n<p>Generator and monitoring compatibility depends on the selected model and configuration. Confirm generator capacity, frequency stability and the required RS-232, RS-485, USB, Modbus or SNMP interface before ordering.<\/p>\n<h2>Request a Project Configuration<\/h2>\n<p>Send DAXIN ENERGY the load list, site voltage, required runtime, installation environment, communications and redundancy requirements. The final configuration is subject to the approved technical proposal.<\/p>\n<\/section>\n<p><!-- DAXIN-HF-SEO-GEO-04-END --><\/p>\n<p><!-- DAXIN-HF-VIDEO-START --><\/p>\n<section class=\"daxin-product-video\">\n<h2>DAXIN High-Frequency UPS Product Video<\/h2>\n<p>Watch the product demonstration to review the UPS format, operating interface and application positioning. Final electrical configuration is subject to the approved technical proposal.<\/p>\n<div class=\"daxin-product-video-item\">\n<h3>H1KR(L)-H10KR(L) Series High-Frequency Rackmount Online UPS Best For Industrial Applications<\/h3>\n<figure class=\"wp-block-video\"><video src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-high-frequency-ups-befadb703763.mp4\" poster=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-h1kr-product-view-1200x1200-1.webp?wsr\" preload=\"metadata\" controls=\"controls\" width=\"300\" height=\"150\">Your browser does not support the video tag.<\/video><figcaption>H1KR(L)-H10KR(L) Series High-Frequency Rackmount Online UPS Best For Industrial Applications &#8211; DAXIN ENERGY.<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<p><!-- DAXIN-HF-VIDEO-END --><\/p>\n<h2>What Is the DAXIN H1KR High-Frequency Rack-Mount UPS?<\/h2>\n<p>The DAXIN H1KR is a compact high-frequency online UPS designed for rack deployment and protected power delivery to critical electronic loads.<\/p>\n<figure class=\"wp-block-image size-full\"><figcaption>Product View for DAXIN H1KR High-Frequency Rack-Mount UPS.<\/figcaption><\/figure>\n<h2>Key Benefits<\/h2>\n<ul>\n<li>Online power-conversion architecture supports continuous load protection.<\/li>\n<li>Rack-mount format uses equipment-cabinet space efficiently.<\/li>\n<li>LCD operating information supports local status review.<\/li>\n<li>Generator, communication, bypass and battery options depend on the selected model.<\/li>\n<li>Compact construction suits distributed critical-load deployments.<\/li>\n<\/ul>\n<h2>Product Views and Technical Reference<\/h2>\n<figure class=\"wp-block-image size-full\"><figcaption>Product View for DAXIN H1KR High-Frequency Rack-Mount UPS.<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\"><figcaption>Alternate Product View for DAXIN H1KR High-Frequency Rack-Mount UPS.<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\"><figcaption>Rear or Side View for DAXIN H1KR High-Frequency Rack-Mount UPS.<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\">\n<table>\n<thead>\n<tr>\n<th>Item<\/th>\n<th>H1KR(L)<\/th>\n<th>H2KR(L)<\/th>\n<th>H3KR(L)<\/th>\n<th>H6KR(L)<\/th>\n<th>H10KR(L)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Model<\/strong><\/td>\n<td>H1KR(L)<\/td>\n<td>H2KR(L)<\/td>\n<td>H3KR(L)<\/td>\n<td>H6KR(L)<\/td>\n<td>H10KR(L)<\/td>\n<\/tr>\n<tr>\n<td>Capacity<\/td>\n<td>1kVA\/0.8kW<\/td>\n<td>2kVA\/1.6kW<\/td>\n<td>3kVA\/2.4kW<\/td>\n<td>6kVA\/6kW<\/td>\n<td>10kVA\/10kW<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Input<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Voltage Range<\/p>\n<div><\/div>\n<p>Min Transfer Voltage<\/p>\n<div><\/div>\n<p>Min Original Voltage<\/p>\n<div><\/div>\n<p>Max Original Voltage<\/td>\n<td>180VAC\/160VAC\/140VAC\/120VAC\u00b15% (Ambient Temp\uff1c35\u2103)<\/p>\n<div><\/div>\n<p>(Load:100%\u201180% \/80%\u201170% \/70\u201160% \/60\u20110%)<\/p>\n<div><\/div>\n<p>195VAC\/175VAC\/155VAC\/135VAC\u00b15% (Ambient Temp\uff1c35\u2103)<\/p>\n<div><\/div>\n<p>(Load:100%\u201180% \/80%\u201170% \/70\u201160% \/60\u20110%)<\/p>\n<div><\/div>\n<p>300VAC \u00b15%<\/p>\n<div><\/div>\n<p>290VAC \u00b15%<\/td>\n<td>180VAC\/160VAC\/140VAC\/120VAC\u00b15% (Ambient Temp\uff1c35\u2103)<\/p>\n<div><\/div>\n<p>(Load:100%\u201180% \/80%\u201170% \/70\u201160% \/60\u20110%)<\/p>\n<div><\/div>\n<p>195VAC\/175VAC\/155VAC\/135VAC\u00b15% (Ambient Temp\uff1c35\u2103)<\/p>\n<div><\/div>\n<p>(Load:100%\u201180% \/80%\u201170% \/70\u201160% \/60\u20110%)<\/p>\n<div><\/div>\n<p>300VAC \u00b15%<\/p>\n<div><\/div>\n<p>290VAC \u00b15%<\/td>\n<td>180VAC\/160VAC\/140VAC\/120VAC\u00b15% (Ambient Temp\uff1c35\u2103)<\/p>\n<div><\/div>\n<p>(Load:100%\u201180% \/80%\u201170% \/70\u201160% \/60\u20110%)<\/p>\n<div><\/div>\n<p>195VAC\/175VAC\/155VAC\/135VAC\u00b15% (Ambient Temp\uff1c35\u2103)<\/p>\n<div><\/div>\n<p>(Load:100%\u201180% \/80%\u201170% \/70\u201160% \/60\u20110%)<\/p>\n<div><\/div>\n<p>300VAC \u00b15%<\/p>\n<div><\/div>\n<p>290VAC \u00b15%<\/td>\n<td>110\u2011300VAC \u00b13% @60% load<\/p>\n<div><\/div>\n<p>176\u2011300VAC \u00b13% @100% load<\/p>\n<div><\/div>\n<p>Min transfer voltage +10V<\/p>\n<div><\/div>\n<p>300VAC \u00b13%<\/p>\n<div><\/div>\n<p>Max transfer voltage\u201110V<\/td>\n<td>110\u2011300VAC \u00b13% @60% load<\/p>\n<div><\/div>\n<p>176\u2011300VAC \u00b13% @100% load<\/p>\n<div><\/div>\n<p>Min transfer voltage +10V<\/p>\n<div><\/div>\n<p>300VAC \u00b13%<\/p>\n<div><\/div>\n<p>Max transfer voltage\u201110V<\/td>\n<\/tr>\n<tr>\n<td>Frequency Range<\/td>\n<td>40Hz\u201170Hz<\/td>\n<td>40Hz\u201170Hz<\/td>\n<td>40Hz\u201170Hz<\/td>\n<td>46\u201154Hz@50Hz system; 56\u201164Hz@60Hz system<\/td>\n<td>46\u201154Hz@50Hz system; 56\u201164Hz@60Hz system<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>Single\u2011phase grounded<\/td>\n<td>Single\u2011phase grounded<\/td>\n<td>Single\u2011phase grounded<\/td>\n<td>Single\u2011phase grounded<\/td>\n<td>Single\u2011phase grounded<\/td>\n<\/tr>\n<tr>\n<td>Power Factor<\/td>\n<td>\u22650.99 @220\u2011230VAC (input voltage)<\/td>\n<td>\u22650.99 @220\u2011230VAC (input voltage)<\/td>\n<td>\u22650.99 @220\u2011230VAC (input voltage)<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Output<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Output Voltage<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<td>208\/220\/230\/240VAC<\/td>\n<\/tr>\n<tr>\n<td>AC Voltage Range<\/td>\n<td>\u00b11% (Battery Mode)<\/td>\n<td>\u00b11% (Battery Mode)<\/td>\n<td>\u00b11% (Battery Mode)<\/td>\n<td>\u00b11% (Battery Mode)<\/td>\n<td>\u00b11% (Battery Mode)<\/td>\n<\/tr>\n<tr>\n<td>Frequency Range (Sync Range)<\/td>\n<td>47\u201153Hz or 57\u201163Hz<\/td>\n<td>47\u201153Hz or 57\u201163Hz<\/td>\n<td>47\u201153Hz or 57\u201163Hz<\/td>\n<td>46\u201154Hz@50Hz system; 56\u201164Hz@60Hz system<\/td>\n<td>46\u201154Hz@50Hz system; 56\u201164Hz@60Hz system<\/td>\n<\/tr>\n<tr>\n<td>Frequency Range (Battery Mode)<\/td>\n<td>50Hz\u00b10.25Hz or 60Hz\u00b10.3Hz<\/td>\n<td>50Hz\u00b10.25Hz or 60Hz\u00b10.3Hz<\/td>\n<td>50Hz\u00b10.25Hz or 60Hz\u00b10.3Hz<\/td>\n<td>50Hz\u00b10.1Hz or 60Hz\u00b10.1Hz<\/td>\n<td>50Hz\u00b10.1Hz or 60Hz\u00b10.1Hz<\/td>\n<\/tr>\n<tr>\n<td>Overload<\/td>\n<td>Ambient temp\uff1c35\u2103:105\u2011110%:10min; UPS auto\u2011restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110\u2011130%:30s auto\u2011shutdown in battery mode; transfer to bypass with normal input.\uff1e130%:UPS auto\u2011shutdown in battery mode; transfer to bypass with normal input.\uff1e150%:Instant protection<\/td>\n<td>Ambient temp\uff1c35\u2103:105\u2011110%:10min; UPS auto\u2011restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110\u2011130%:30s auto\u2011shutdown in battery mode; transfer to bypass with normal input.\uff1e130%:UPS auto\u2011shutdown in battery mode; transfer to bypass with normal input.\uff1e150%:Instant protection<\/td>\n<td>Ambient temp\uff1c35\u2103:105\u2011110%:10min; UPS auto\u2011restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110\u2011130%:30s auto\u2011shutdown in battery mode; transfer to bypass with normal input.\uff1e130%:UPS auto\u2011shutdown in battery mode; transfer to bypass with normal input.\uff1e150%:Instant protection<\/td>\n<td>100\u2011110%:30min; 110\u2011130%:5min; \uff1e130%:10s<\/td>\n<td>100\u2011110%:30min; 110\u2011130%:5min; \uff1e130%:10s<\/td>\n<\/tr>\n<tr>\n<td>Current Crest Factor<\/td>\n<td>3:1<\/td>\n<td>3:1<\/td>\n<td>3:1<\/td>\n<td>3:1<\/td>\n<td>3:1<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td>\u22643% THD (linear load); \u22646% THD (non\u2011linear load)<\/td>\n<td>\u22643% THD (linear load); \u22646% THD (non\u2011linear load)<\/td>\n<td>\u22643% THD (linear load); \u22646% THD (non\u2011linear load)<\/td>\n<td>\u22641% @100% (linear load); \u22644% @100% (non\u2011linear load)<\/td>\n<td>\u22641% @100% (linear load); \u22644% @100% (non\u2011linear load)<\/td>\n<\/tr>\n<tr>\n<td>Transfer Time<\/p>\n<div><\/div>\n<p>Mains to Battery<\/p>\n<div><\/div>\n<p>Inverter to Bypass<\/td>\n<td>4ms (standard condition)<\/p>\n<div><\/div>\n<p>Pure sine wave<\/td>\n<td>4ms (standard condition)<\/p>\n<div><\/div>\n<p>Pure sine wave<\/td>\n<td>4ms (standard condition)<\/p>\n<div><\/div>\n<p>Pure sine wave<\/td>\n<td>0ms<\/p>\n<div><\/div>\n<p>N\/A<\/td>\n<td>0ms<\/p>\n<div><\/div>\n<p>N\/A<\/td>\n<\/tr>\n<tr>\n<td>Waveform (Battery Mode)<\/td>\n<td>Pure sine wave<\/td>\n<td>Pure sine wave<\/td>\n<td>Pure sine wave<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Efficiency<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>AC Mode<\/td>\n<td>88%<\/td>\n<td>89%<\/td>\n<td>90%<\/td>\n<td>\uff1e95% (Max)<\/td>\n<td>\uff1e95% (Max)<\/td>\n<\/tr>\n<tr>\n<td>Battery Mode<\/td>\n<td>83%<\/td>\n<td>85%<\/td>\n<td>88%<\/td>\n<td>\uff1e93% (Max)<\/td>\n<td>\uff1e93% (Max)<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Battery \u2014 Standard Model<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Battery Model<\/td>\n<td>12V\/7AH<\/td>\n<td>12V\/7AH<\/td>\n<td>12V\/7AH<\/td>\n<td>12V\/7AH<\/td>\n<td>12V\/9AH<\/td>\n<\/tr>\n<tr>\n<td>Battery Quantity<\/td>\n<td>2<\/td>\n<td>4<\/td>\n<td>6<\/td>\n<td>16<\/td>\n<td>16<\/td>\n<\/tr>\n<tr>\n<td>Charging Current<\/td>\n<td>1A<\/td>\n<td>1A<\/td>\n<td>1A<\/td>\n<td>1A\u00b110% (Default)<\/td>\n<td>1A\u00b110% (Default)<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Battery \u2014 Long\u2011run Model<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Battery Model<\/td>\n<td>Subject to supplier<\/td>\n<td>Subject to supplier<\/td>\n<td>Subject to supplier<\/td>\n<td>Subject to application<\/td>\n<td>Subject to application<\/td>\n<\/tr>\n<tr>\n<td>Battery Quantity<\/td>\n<td>3<\/td>\n<td>6<\/td>\n<td>8<\/td>\n<td>16\u201120<\/td>\n<td>16\u201120<\/td>\n<\/tr>\n<tr>\n<td>Charging Current<\/td>\n<td>1A\/2A\/4A\/6A<\/td>\n<td>1A\/2A\/4A\/6A<\/td>\n<td>1A\/2A\/4A\/6A<\/td>\n<td>2A\u00b110% (Default); Optional:1A\/2A\/4A\/6A\/8A<\/td>\n<td>2A\u00b110% (Default); Optional:1A\/2A\/4A\/6A\/8A<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Physical Performance \u2014 Standard Model<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Dimension: D\u00d7W\u00d7H (mm)<\/td>\n<td>310\u00d7438\u00d788<\/td>\n<td>410\u00d7438\u00d788<\/td>\n<td>630\u00d7438\u00d788<\/td>\n<td>UPS:509\u00d7438\u00d788 [2U]<\/p>\n<div><\/div>\n<p>Battery Pack:688\u00d7438\u00d788 [2U]<\/td>\n<td>UPS:509\u00d7438\u00d788 [2U]<\/p>\n<div><\/div>\n<p>Battery Pack:688\u00d7438\u00d788 [2U]<\/td>\n<\/tr>\n<tr>\n<td>Net Weight (kg)<\/td>\n<td>12<\/td>\n<td>19<\/td>\n<td>29.3<\/td>\n<td>UPS:11; Battery Pack:48<\/td>\n<td>UPS:12.1; Battery Pack:53<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Physical Performance \u2014 Long\u2011run Model<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Dimension: D\u00d7W\u00d7H (mm)<\/td>\n<td>310\u00d7438\u00d788<\/td>\n<td>410\u00d7438\u00d788<\/td>\n<td>410\u00d7438\u00d788<\/td>\n<td>530\u00d7438\u00d788 [2U]<\/td>\n<td>580\u00d7438\u00d7133 [3U]<\/td>\n<\/tr>\n<tr>\n<td>Net Weight (kg)<\/td>\n<td>9<\/td>\n<td>12<\/td>\n<td>14.2<\/td>\n<td>11<\/td>\n<td>12.1<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Operating Environment<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Operating Humidity<\/td>\n<td>20\u201190% RH @0\u201140\u2103 (Non\u2011condensing)<\/td>\n<td>20\u201190% RH @0\u201140\u2103 (Non\u2011condensing)<\/td>\n<td>20\u201190% RH @0\u201140\u2103 (Non\u2011condensing)<\/td>\n<td>\uff1c95% &amp; non\u2011condensing<\/td>\n<td>\uff1c95% &amp; non\u2011condensing<\/td>\n<\/tr>\n<tr>\n<td>Noise<\/td>\n<td>\uff1c50dB@1 Meter<\/td>\n<td>\uff1c50dB@1 Meter<\/td>\n<td>\uff1c50dB@1 Meter<\/td>\n<td>\uff1c55dB@1 Meter<\/td>\n<td>\uff1c58dB@1 Meter<\/td>\n<\/tr>\n<tr>\n<td>Operating Temperature<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>0\u201140\u2103 (Battery life shortens above 25\u2103)<\/td>\n<td>0\u201140\u2103 (Battery life shortens above 25\u2103)<\/td>\n<\/tr>\n<tr>\n<td>Max Operating Altitude<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>N\/A<\/td>\n<td>\uff1c1000m**<\/td>\n<td>\uff1c1000m**<\/td>\n<\/tr>\n<tr>\n<td><strong class=\"container-nB6Z1e\">Control &amp; Management<\/strong><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Intelligent RS\u2011232\/USB<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008\/7\/8, Linux, Unix and MAC<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008\/7\/8, Linux, Unix and MAC<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008\/7\/8, Linux, Unix and MAC<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008\/7\/8, Linux, Unix and MAC<\/td>\n<td>Support Windows\u00ae2000\/2003\/XP\/Vista\/2008\/7\/8, Linux, Unix and MAC<\/td>\n<\/tr>\n<tr>\n<td>Optional SNMP<\/td>\n<td>Power management via SNMP manager and web browser<\/td>\n<td>Power management via SNMP manager and web browser<\/td>\n<td>Power management via SNMP manager and web browser<\/td>\n<td>Power management via SNMP manager and web browser<\/td>\n<td>Power management via SNMP manager and web browser<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Footer Note:<br \/>\nSpecifications are subject to change without prior notice.<figcaption>Technical Reference for DAXIN H1KR High-Frequency Rack-Mount UPS.<\/figcaption><\/figure>\n<h2>Typical Applications<\/h2>\n<p>Server cabinets, network rooms, telecom systems, security equipment, finance, education and distributed IT loads.<\/p>\n<h2>Selection and Project Planning<\/h2>\n<p>Confirm the exact power rating, input\/output phase, voltage, frequency, power factor, battery voltage, runtime, bypass, communications, dimensions, environmental limits and installation method against the selected model and project drawings before ordering.<\/p>\n<h2>Frequently Asked Questions<\/h2>\n<h3>Can this product be configured for a specific project?<\/h3>\n<p>Yes. Electrical configuration, battery runtime, communications, bypass, cabinet arrangement and project accessories can be reviewed against the site requirements.<\/p>\n<h3>Are all technical ratings shared across the full series?<\/h3>\n<p>No. Ratings and functions vary by model and configuration. Use the project-specific technical sheet as the final reference.<\/p>\n<h3>Can DAXIN ENERGY support system selection?<\/h3>\n<p>Yes. Provide the load list, phase and voltage, required runtime, redundancy target, communication requirements and installation environment.<\/p>\n<h2>Request a Project Configuration<\/h2>\n<p>Send the load data, single-line diagram, required backup time and site conditions to receive a tailored UPS or battery proposal.<\/p>\n<figure id=\"attachment_4735\" aria-describedby=\"caption-attachment-4735\" style=\"width: 982px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4735\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/ups-power-solution-provider-english.webp\" alt=\"DAXIN ENERGY UPS Power Solution Provider for Data Centers and Industrial Applications\" width=\"982\" height=\"664\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/ups-power-solution-provider-english.webp 982w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/ups-power-solution-provider-english-300x203.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/ups-power-solution-provider-english-768x519.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/ups-power-solution-provider-english-18x12.webp 18w\" sizes=\"auto, (max-width: 982px) 100vw, 982px\" \/><figcaption id=\"caption-attachment-4735\" class=\"wp-caption-text\">UPS Power Solution Provider &#8211; DAXIN ENERGY<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>The DAXIN H1KR is a compact high-frequency online UPS designed for rack deployment and protected power delivery to critical electronic loads.<\/p>\n","protected":false},"featured_media":4740,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[105,98,97],"product_tag":[],"class_list":["post-2845","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-high-frequency-rack-mount-ups","product_cat-high-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product\/2845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/comments?post=2845"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/media\/4740"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/media?parent=2845"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_brand?post=2845"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_cat?post=2845"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_tag?post=2845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}