{"id":182,"date":"2026-04-27T10:58:27","date_gmt":"2026-04-27T10:58:27","guid":{"rendered":"http:\/\/btrytech.com\/?post_type=product&#038;p=182"},"modified":"2026-04-27T10:59:29","modified_gmt":"2026-04-27T10:59:29","slug":"11-h3kva-standard-online-double-conversion-ups-3000va-2700w-power-protection","status":"publish","type":"product","link":"https:\/\/btrytech.com\/en\/product\/11-h3kva-standard-online-double-conversion-ups-3000va-2700w-power-protection\/","title":{"rendered":"11-H3kVA Standard Online Double-Conversion UPS &#8211; 3000VA\/2700W Power Protection"},"content":{"rendered":"<h3 class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">11-H3kVA (Standard Model)<\/span><\/h3>\n<h4 class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">I. Power Range: 3kVA<\/span><\/h4>\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Working Mode:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Single-phase input \/ Single-phase output, Online Double-Conversion.<\/span><br class=\"ng-star-inserted\" \/><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Applications:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Widely used across various sectors including government, finance, telecommunications, education, transportation, meteorology, broadcasting, taxation, healthcare, energy, and power industries.<\/span><\/p>\n<h4 class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Product Features:<\/span><\/h4>\n<ul class=\"ng-star-inserted\">\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">True Online Double-Conversion:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Provides continuous, high-quality power by isolating the load from utility irregularities.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Microprocessor Control:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Ensures high reliability and precise operation through advanced digital management.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Input Power Factor Correction:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Optimizes energy usage and reduces harmonic distortion on the grid.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">High Output Power Factor:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Output Power Factor reaches up to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">0.9<\/span><\/strong><span class=\"ng-star-inserted\">, providing more real power for connected loads.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Wide Input Voltage Range (90V \u2013 300V):<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Capable of operating in unstable power environments without switching to battery mode.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Efficient Frequency Converter Mode:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Supports conversion between 50Hz and 60Hz to meet specialized equipment needs.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Generator Compatible:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Works seamlessly with backup generator systems.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Enhanced Monitoring Options:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Optional SNMP card allows for standalone monitoring or integrated management via USB and RS232 ports.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">User-Friendly LCD Display:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Offers simple operation and comprehensive, real-time monitoring of UPS status.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">ECO Mode:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Provides high-efficiency energy-saving operation to reduce electricity costs.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Emergency Power Off (EPO):<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Allows for immediate shutdown in the event of an emergency.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">DSP Technology:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Built on advanced Digital Signal Processing technology; optional maintenance bypass switch available.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Smart Battery Charger Design:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Optimizes battery performance and significantly extends battery lifespan.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Isolation Transformer:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Optional built-in isolation transformer for enhanced electrical protection.<\/span><\/p>\n<\/li>\n<\/ul>\n<h4 class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">II. Technical Notes:<br \/>\n<\/span><\/h4>\n<table>\n<thead>\n<tr>\n<th align=\"left\">Item<\/th>\n<th align=\"left\">11-H1kVA<\/th>\n<th align=\"left\">11-H2kVA<\/th>\n<th align=\"left\">11-H3kVA<\/th>\n<th align=\"left\">11-H6kVA<\/th>\n<th align=\"left\">11-H10kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\"><strong>Model<\/strong><\/td>\n<td align=\"left\">11-H1kVA<\/td>\n<td align=\"left\">11-H2kVA<\/td>\n<td align=\"left\">11-H3kVA<\/td>\n<td align=\"left\">11-H6kVA<\/td>\n<td align=\"left\">11-H10kVA<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Capacity<\/strong><\/td>\n<td align=\"left\">1000VA\/900W<\/td>\n<td align=\"left\">2000VA\/1800W<\/td>\n<td align=\"left\">3000VA\/2700W<\/td>\n<td align=\"left\">6000VA\/5400W<\/td>\n<td align=\"left\">10000VA\/9000W<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">### Input<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Phase<\/td>\n<td align=\"left\">Single-phase grounded<\/td>\n<td align=\"left\">Single-phase grounded<\/td>\n<td align=\"left\">Single-phase grounded<\/td>\n<td align=\"left\">Single-phase grounded<\/td>\n<td align=\"left\">Single-phase grounded<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Minimum Transfer Voltage<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">160VAC\/140VAC\/120VAC\/110VAC \u00b15% (Ambient temp \uff1c35\u2103; Load Ratio: 100%-80%-80%-70%-70%-70%-60%-60%-0)<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">50% Load: 110VAC \u00b13%;<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>100% Load: 176VAC \u00b13%<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Minimum Restore Voltage<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">195VAC\/175VAC\/155VAC\/135VAC \u00b15% (Ambient temp \uff1c35\u2103; Load Ratio: 100%-80%-80%-70%-70%-60%-60%-0)<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">Minimum transfer voltage +10V<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Maximum Transfer Voltage<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">300VAC \u00b15%<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">300VAC \u00b13%<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Maximum Restore Voltage<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">290VAC \u00b15%<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">Maximum transfer voltage -10V<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency Range<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">40Hz ~ 70Hz<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">46Hz~54Hz (@50Hz System);<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>56Hz~64Hz (@60Hz System)<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Input Power Factor<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">\u22650.99 @ 220-230-240VAC<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">N\/A<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">### Output<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Output Voltage<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">208\/220\/230\/240VAC \u00b11%<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">208\/220\/230\/240VAC \u00b11%<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency Range (Synchronization)<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">47-53Hz or 57-63Hz<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">46-54Hz or 56-64Hz<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency Range (Battery Mode)<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">50\u00b10.25Hz or 60\u00b10.3Hz<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">50\u00b10.1Hz or 60\u00b10.1Hz<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Crest Factor<\/td>\n<td align=\"left\">colspan=&#8221;5&#8243;<\/td>\n<td align=\"left\">3:1<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Total Harmonic Distortion (THD)<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">\u22643% THD (Linear Load); \u22646% THD (Non-linear Load)<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">\u22643% THD (Linear Load); \u22645% THD (Non-linear Load)<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Overload Capacity<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">Temp\uff1c35\u2103:<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>105%-110%: Auto-restart after 10s fault, recover output within 1s when input normalizes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>110%-130%: Auto-shutdown after 3 mins, recover after 3s when input normalizes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>\uff1e150%: Instant UPS shutdown<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">100%~110%: 30 Minutes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>110%~130%: 5 Minutes<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>\uff1e130%: 10 Seconds<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Transfer Time (Mains to Battery)<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">0ms<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">0ms<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Transfer Time (Inverter to Bypass)<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">4ms (Standard Condition)<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">0ms<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Waveform (Battery Mode)<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">Pure Sine Wave<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">N\/A<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">### Efficiency<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Mains Mode<\/td>\n<td align=\"left\">88%<\/td>\n<td align=\"left\">89%<\/td>\n<td align=\"left\">90%<\/td>\n<td align=\"left\">92%<\/td>\n<td align=\"left\">93%<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Mode<\/td>\n<td align=\"left\">83%<\/td>\n<td align=\"left\">87%<\/td>\n<td align=\"left\">88%<\/td>\n<td align=\"left\">90%<\/td>\n<td align=\"left\">91%<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">### Battery<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Standard Unit (S)<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Type<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">12V\/7Ah<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">12V\/7Ah<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Quantity<\/td>\n<td align=\"left\">2<\/td>\n<td align=\"left\">4<\/td>\n<td align=\"left\">6<\/td>\n<td align=\"left\">12<\/td>\n<td align=\"left\">16<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Charging Current<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">1.0A<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">Preset: 1.0A \u00b110%, Max: 1A\/2A<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Long-run Unit (L)<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Type<\/td>\n<td align=\"left\">colspan=&#8221;5&#8243;<\/td>\n<td align=\"left\">12V\/AH (Customized per buyer request)<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Quantity<\/td>\n<td align=\"left\">3<\/td>\n<td align=\"left\">3<\/td>\n<td align=\"left\">8<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">Model-dependent<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Charging Current<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">1A\/2A\/4A\/6A<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">1A\/2A\/4A\/6A (Adjustable);<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>6A only applicable for 16-cell battery pack<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">### Physical Specifications<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Standard Unit<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Dimension (D\u00d7W\u00d7H, mm)<\/td>\n<td align=\"left\">282\u00d7145\u00d7220<\/td>\n<td align=\"left\">397\u00d7145\u00d7220<\/td>\n<td align=\"left\">421\u00d7190\u00d7318<\/td>\n<td align=\"left\">369\u00d7190\u00d7688<\/td>\n<td align=\"left\">442\u00d7190\u00d7688<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Net Weight (kg)<\/td>\n<td align=\"left\">9.8<\/td>\n<td align=\"left\">17<\/td>\n<td align=\"left\">26.2<\/td>\n<td align=\"left\">51<\/td>\n<td align=\"left\">55<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Long-run Unit<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Dimension (D\u00d7W\u00d7H, mm)<\/td>\n<td align=\"left\">282\u00d7145\u00d7220<\/td>\n<td align=\"left\">397\u00d7145\u00d7220<\/td>\n<td align=\"left\">421\u00d7190\u00d7318<\/td>\n<td align=\"left\">369\u00d7190\u00d7318<\/td>\n<td align=\"left\">442\u00d7190\u00d7318<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Net Weight (kg)<\/td>\n<td align=\"left\">4.4<\/td>\n<td align=\"left\">6.8<\/td>\n<td align=\"left\">7.4<\/td>\n<td align=\"left\">12<\/td>\n<td align=\"left\">15<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">### Operating Environment<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Operating Humidity<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">20-90% RH, 0-40\u2103 (Non-condensing)<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">\uff1c95% RH, Non-condensing<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Noise<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">\uff1c50dB @ 1 Meter<\/td>\n<td align=\"left\">\uff1c55dB @ 1 Meter<\/td>\n<td align=\"left\">\uff1c58dB @ 1 Meter<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Operating Temperature<\/td>\n<td align=\"left\">colspan=&#8221;3&#8243;<\/td>\n<td align=\"left\">N\/A<\/td>\n<td align=\"left\">colspan=&#8221;2&#8243;<\/td>\n<td align=\"left\">0 ~ 40\u2103 (Battery lifespan shortened above 25\u2103 ambient temp)<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">### Control &amp; Management<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Intelligent RS-232\/USB<\/td>\n<td align=\"left\">colspan=&#8221;5&#8243;<\/td>\n<td align=\"left\">Compatible with Windows 2000\/2003\/XP\/Vista\/2008, Windows7\/8, Linux &amp; MAC<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Optional SNMP Card<\/td>\n<td align=\"left\">colspan=&#8221;5&#8243;<\/td>\n<td align=\"left\">Supports SNMP network management &amp; remote monitoring<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<ul class=\"ng-star-inserted\">\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Derating Rules for 1-3kVA Models:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Output power will be derated to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">80%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0of capacity when the UPS is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">CVCF<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0(Constant Voltage Constant Frequency) mode or when the output voltage is configured to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">208VAC<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Derating Rules for 6\/10kVA Models:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Output power will be derated to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">60%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0in\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">CVCF<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0mode and to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">90%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0when the output voltage is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">208VAC<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Parallel Redundancy:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0The standard models listed above currently do not support parallel redundancy.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Voltage Support:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0Output voltage settings of\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">200\/208\/220\/230\/240VAC<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0are only applicable to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">Long-run (L)<\/span><\/strong><span class=\"ng-star-inserted\"> models.<br \/>\n<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">For 1-3kVA UPS:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0The output power is\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">derated to 80%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0when operating in\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">CVCF<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0(Constant Voltage Constant Frequency) mode or when the output voltage is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">208VAC<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">For 6\/10kVA UPS:<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0The output power is\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">derated to 60%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0in\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">CVCF<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0mode and to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">90%<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0when the output voltage is set to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">208VAC<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">The standard models mentioned above currently\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">do not support parallel redundancy<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><\/p>\n<\/li>\n<li class=\"ng-star-inserted\">\n<p class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">The voltage settings of\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">200\/208\/220\/230\/240VAC<\/span><\/strong><span class=\"ng-star-inserted\">\u00a0are only applicable to\u00a0<\/span><strong class=\"ng-star-inserted\"><span class=\"ng-star-inserted\">long-run models<\/span><\/strong><span class=\"ng-star-inserted\">.<\/span><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-179 size-full\" src=\"http:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1.jpg\" alt=\"\" width=\"925\" height=\"591\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1.jpg 925w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1-600x383.jpg 600w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1-300x192.jpg 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-1-768x491.jpg 768w\" sizes=\"auto, (max-width: 925px) 100vw, 925px\" \/><\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The 11-H3kVA Standard Model is a high-performance 3kVA online double-conversion UPS featuring DSP technology, a 0.9 output power factor, and a wide input voltage range (90V-300V). Ideal for government, telecom, and medical applications. Includes smart battery management and optional SNMP monitoring.<\/p>\n","protected":false},"featured_media":164,"comment_status":"open","ping_status":"closed","template":"","meta":{"_crdt_document":""},"product_brand":[46],"product_cat":[102,98,97],"product_tag":[131,127,132,129,130,128],"class_list":["post-182","product","type-product","status-publish","has-post-thumbnail","product_brand-szdxzh","product_cat-hf-1-1-phase-ups","product_cat-high-frequency-ups","product_cat-ups-solutions","product_tag-11-h3kva-technical-specifications","product_tag-3kva-online-ups","product_tag-3kva-ups-with-0-9-power-factor","product_tag-online-double-conversion-3kva","product_tag-single-phase-ups-for-telecom","product_tag-standard-model-ups-3000va","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product\/182","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/comments?post=182"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/media\/164"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/media?parent=182"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_brand?post=182"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_cat?post=182"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/en\/wp-json\/wp\/v2\/product_tag?post=182"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}