11-H 2kVA Online UPS (Standard Model) Power Supply | Double Conversion Uninterruptible Power System

The 11-H 2kVA Online UPS features double conversion technology to deliver reliable power protection for office equipment, telecom systems, and small data centers. It offers high efficiency and intelligent battery management.

Get a Quote & Technical Support

Send your application, quantity and technical requirements. Our engineering team will respond with a suitable configuration.

Description

The 11-H 2kVA Online UPS uses advanced double-conversion technology to provide stable, clean, and uninterrupted power for critical equipment. With high reliability and performance, it is an ideal power protection solution for small to medium-scale applications.

Widely used in government, finance, telecommunications, education, transportation, meteorology, broadcasting, taxation, healthcare, and energy industries.

  • True double-conversion online technology with zero transfer time
  • Microprocessor control for high reliability
  • Input Power Factor Correction (PFC)
  • Output power factor up to 0.9
  • Wide input voltage range (90V–300V)
  • High-efficiency frequency conversion mode
  • Generator compatible
  • Optional SNMP card with USB and RS232 monitoring
  • User-friendly LCD display
  • ECO mode for energy saving
  • Emergency Power Off (EPO)
  • DSP-based digital control technology
  • Built-in maintenance bypass (optional)
  • Intelligent battery management system
  • Optional isolation transformer
    Notes

    • For 1–3kVA UPS in frequency conversion mode, output derates to 80%
    • At 208VAC output, power derates to 80%
    • Parallel redundancy is not supported
    • 200/208/220/230/240VAC applies only to long backup models
    Parameter11-H1kVA11-H2kVA11-H3kVA11-H6kVA11-H10kVA
    Model11-H1kVA11-H2kVA11-H3kVA11-H6kVA11-H10kVA
    Capacity1000VA/900W2000VA/1800W3000VA/2700W6000VA/5400W10000VA/9000W
    Input
    Phasemulticolumn{3}{c}{Single-phase, grounded}multicolumn{2}{c}{Single-phase, grounded}
    Voltage Range
    Lowest Transfer Voltagemulticolumn{3}{c}{160/140/120/110VAC ±5% (Ambient temp <35°C)

    (Adjustable load ratio: 100%-80% / 80%-70% / 70%-60% / 60%-0)}

    multicolumn{2}{c}{50% load: 110VAC ±3%

    100% load: 176VAC ±3%}

    Lowest Restore Voltagemulticolumn{3}{c}{195/175/155/135VAC ±5% (Ambient temp <35°C)

    (Adjustable load ratio: 100%-80% / 80%-70% / 70%-60% / 60%-0)}

    multicolumn{2}{c}{Lowest transfer voltage +10V}
    Highest Transfer Voltagemulticolumn{3}{c}{300VAC ±5%}multicolumn{2}{c}{300VAC ±3%}
    Highest Restore Voltagemulticolumn{3}{c}{290VAC ±5%}multicolumn{2}{c}{Highest transfer voltage -10V}
    Frequency Rangemulticolumn{3}{c}{40Hz~70Hz}multicolumn{2}{c}{46Hz~54Hz @ 50Hz system; 56Hz~64Hz @ 60Hz system}
    Power Specificationsmulticolumn{3}{c}{≤0.99 @ 220-230VAC (input voltage)}multicolumn{2}{c}{N/A}
    Output
    Output Voltagemulticolumn{5}{c}{208/220/230/240VAC ±1%}
    Mains Voltage Range (Battery Mode)multicolumn{5}{c}{±1%}
    Frequency Range (Synchronization Range)multicolumn{3}{c}{47-53Hz or 57-63Hz}multicolumn{2}{c}{46-54Hz or 56-64Hz}
    Frequency Range (Battery Mode)multicolumn{3}{c}{50±0.25Hz or 60±0.3Hz}multicolumn{2}{c}{50±0.1Hz or 60±0.1Hz}
    Crest Factormulticolumn{5}{c}{3:1}
    Harmonic Distortionmulticolumn{3}{c}{≤3% THD (linear load); ≤6% THD (non-linear load)}multicolumn{2}{c}{≤3% THD (linear load); ≤5% THD (non-linear load)}
    Overload Capacitymulticolumn{3}{c}{Ambient temp <35°C: 105%-110%: UPS shuts down after 10s in battery mode; transfers to bypass when mains is restored. 110%-130%: UPS shuts down after 3s in battery mode; transfers to bypass when mains is restored. >150%: UPS shuts down immediately.}multicolumn{2}{c}{100%-110%: 30 minutes; 110%-130%: 5 minutes; >130%: 10 seconds}
    Transfer Time
    Mains to Batterymulticolumn{5}{c}{0ms}
    Inverter to Bypassmulticolumn{3}{c}{4ms (standard conditions)}multicolumn{2}{c}{0ms}
    Waveform (Battery Mode)multicolumn{3}{c}{Pure sine wave}multicolumn{2}{c}{N/A}
    Efficiency
    Mains Mode88%89%90%92%93%
    Battery Mode83%87%88%90%91%
    Battery
    Standard Model (S)
    Battery Modelmulticolumn{3}{c}{12V/7Ah}multicolumn{2}{c}{12V/7Ah}
    Quantity2461216
    Charging Current1.0Amulticolumn{2}{c}{Preset: 1.0A ±10%, Max: 1A/2A}
    Long Backup Model (L)
    Battery Modelmulticolumn{5}{c}{12V/AH (varies by application)}
    Quantity3681616
    Charging Current1A/2A/4A/6A1A/2A/4A/6A1A/2A/4A/6A1A/2A/4A/6A (adjustable; 6A only for 16-section batteries)1A/2A/4A/6A (adjustable; 6A only for 16-section batteries)
    Physical Performance
    Standard Model
    Dimensions: D×W×H (mm)282×145×220397×145×220421×190×318369×190×688442×190×688
    Net Weight (kg)9.81726.25155
    Long Backup Model
    Dimensions: D×W×H (mm)282×145×220397×145×220421×190×318369×190×318442×190×318
    Net Weight (kg)4.46.87.41215
    Operating Environment
    Operating Humiditymulticolumn{3}{c}{20-90% RH, 0-40°C (non-condensing)}multicolumn{2}{c}{<95% RH, non-condensing}
    Noise<50dB @ 1m<50dB @ 1m<50dB @ 1m<55dB @ 1m<58dB @ 1m
    Operating Temperaturemulticolumn{3}{c}{N/A}multicolumn{2}{c}{0~40°C (battery life shortened above 25°C)}
    Control & Management
    Smart RS-232/USBmulticolumn{5}{c}{Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux and MAC}
    Optional SNMP Cardmulticolumn{5}{c}{Supports SNMP and network management}

    11-H 2kVA Online UPS (Standard Model) Power Supply | Double Conversion Uninterruptible Power System technical detail 1 by DAXIN ENERGY