{"id":2260,"date":"2026-07-11T17:34:05","date_gmt":"2026-07-11T09:34:05","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=2260"},"modified":"2026-08-12T20:50:13","modified_gmt":"2026-08-12T12:50:13","slug":"180kva-three-phase-online-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/de\/product\/180kva-three-phase-online-ups\/","title":{"rendered":"180 kVA Dreiphasen-Online-USV | DAXIN EX3C3"},"content":{"rendered":"<section class=\"daxin-customer-selection-guide\">\n<h2>What Is the DAXIN EX3C3 180kVA 3\/3 Phase Online UPS?<\/h2>\n<p>The DAXIN EX3C3 180kVA is a high-capacity three-phase input and three-phase output online UPS designed to protect mission-critical electrical and electronic loads.<\/p>\n<p>With online double-conversion topology, the UPS continuously supplies connected loads through the inverter, helping provide stable output during utility voltage fluctuations, frequency variations and power interruptions.<\/p>\n<p>The EX3C3 180kVA reference configuration provides 180kVA\/180kW rated capacity, 380\/400\/415VAC three-phase output, 0ms transfer time, greater than 96.5% efficiency and optional SNMP network management.<\/p>\n<p>Typical applications include data centers, industrial facilities, telecom infrastructure, healthcare systems, transportation infrastructure and other facilities requiring high-capacity three-phase power protection.<\/p>\n<h2>Was Sie vor der Bestellung \u00fcberpr\u00fcfen sollten<\/h2>\n<ul>\n<li>Measured load and expansion allowance<\/li>\n<li>Required redundancy architecture<\/li>\n<li>Battery autonomy and room conditions<\/li>\n<li>Bypass, protection coordination and remote monitoring<\/li>\n<\/ul>\n<h2>Projektkonfiguration anfordern<\/h2>\n<p>Senden Sie DAXIN ENERGY die Lastliste, die Spannung vor Ort, die erforderliche Laufzeit, die Installationsumgebung sowie die Anforderungen an Kommunikation und Redundanz. Die endg\u00fcltige Konfiguration richtet sich nach dem genehmigten technischen Angebot.<\/p>\n<\/section>\n<p><!-- DAXIN-HF-SEO-GEO-04-END --><\/p>\n<p><!-- DAXIN-HF-VIDEO-04-START --><\/p>\n<section class=\"daxin-product-video\">\n<h2>Additional DAXIN High-Frequency UPS Product Video<\/h2>\n<p>Sehen Sie sich die Produktdemonstration an, um sich einen \u00dcberblick \u00fcber den Aufbau der USV, die Bedienoberfl\u00e4che und die Anwendungsbereiche zu verschaffen. Die endg\u00fcltige elektrische Konfiguration richtet sich nach dem genehmigten technischen Angebot.<\/p>\n<div class=\"daxin-product-video-item\">\n<figure class=\"wp-block-video\"><video src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-high-frequency-ups-e5177d36f57b.mp4\" poster=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2260-gallery-01.webp?wsr\" preload=\"metadata\" controls=\"controls\" width=\"300\" height=\"150\">Ihr Browser unterst\u00fctzt das Video-Tag nicht.<\/video><figcaption>Online UPS With Load Capacity 180KVA &#8211; Reliable Power Protection 99.999% Uptime Guarantee &#8211; DAXIN ENERGY.<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<p><!-- DAXIN-HF-VIDEO-04-END --><\/p>\n<h2>EX3C3 180kVA Three-Phase Online UPS<\/h2>\n<p>The DAXIN ENERGY EX3C3 180kVA online UPS is engineered for large-scale critical power backup applications that require reliable three-phase power, high efficiency and stable system operation. Its double-conversion online topology helps isolate sensitive equipment from grid fluctuation, voltage instability, frequency variation, harmonic interference and unexpected power interruptions.<\/p>\n<h2>Wichtigste Merkmale<\/h2>\n<h3>High-Reliability Online Double-Conversion Design<\/h3>\n<ul>\n<li>True online double-conversion topology delivers clean sine wave output for critical loads.<\/li>\n<li>Output frequency tracking, phase locking, voltage regulation and noise filtering reduce the impact of unstable grid power.<\/li>\n<li>Eine fortschrittliche, modulare Dual-CPU-Steuerung verbessert die Systemzuverl\u00e4ssigkeit und die Betriebsstabilit\u00e4t.<\/li>\n<li>Wide AC input voltage range helps reduce unnecessary battery discharge in poor power environments.<\/li>\n<li>Die Gleichstrom-Startfunktion erm\u00f6glicht es der USV, bei Ausfall der Netzstromversorgung direkt aus der Batterie zu starten.<\/li>\n<\/ul>\n<h3>High Efficiency and Grid-Friendly Performance<\/h3>\n<ul>\n<li>Advanced PFC technology keeps the input power factor close to 1.<\/li>\n<li>Durch die Auslegung eines Oberschwingungsfilters auf der Eingangsseite lassen sich R\u00fcckkopplungsst\u00f6rungen im Versorgungsnetz reduzieren.<\/li>\n<li>Input and output harmonic filters minimize harmonic interference caused by the UPS system.<\/li>\n<li>High-frequency filtering and synchronization technology improves compatibility with generator power.<\/li>\n<\/ul>\n<h3>Complete Protection Functions<\/h3>\n<ul>\n<li>Ausgangs\u00fcberlastschutz.<\/li>\n<li>Kurzschlussschutz am Ausgang.<\/li>\n<li>\u00dcbertemperaturschutz des Wechselrichters.<\/li>\n<li>Warnung bei niedriger Batteriespannung.<\/li>\n<li>\u00dcberladeschutz f\u00fcr die Batterie.<\/li>\n<li>Manual maintenance bypass switch supports easier maintenance without interrupting load power.<\/li>\n<\/ul>\n<h3>LCD Display and Intelligent Management<\/h3>\n<ul>\n<li>Das LCD-Display zeigt den Betriebsstatus der USV, die Systemparameter und Alarminformationen in Echtzeit an.<\/li>\n<li>RS232-\/RS485-Kommunikationsschnittstellen erm\u00f6glichen die lokale \u00dcberwachung und die Systemintegration.<\/li>\n<li>Ein optionaler SNMP-Netzwerkadapter erm\u00f6glicht die Fern\u00fcberwachung der USV und ein zentralisiertes Energiemanagement.<\/li>\n<li>Compatible with intelligent UPS monitoring software for clear visibility of operating data.<\/li>\n<\/ul>\n<h3>Optionales intelligentes Batterie\u00fcberwachungsmodul<\/h3>\n<ul>\n<li>Unterst\u00fctzt die Erkennung und \u00dcberwachung einzelner Akkus.<\/li>\n<li>Bietet Alarmfunktionen f\u00fcr \u00dcberspannung, Unterspannung und Spannungsdifferenz.<\/li>\n<li>Informationen zu Batteriefehlern k\u00f6nnen auf dem Bildschirm angezeigt werden, damit Administratoren schnell reagieren k\u00f6nnen.<\/li>\n<\/ul>\n<h3>Hohe Anpassungsf\u00e4higkeit an die Umweltbedingungen<\/h3>\n<p>The circuit boards are installed in a fully enclosed structure and treated with conformal coating, improving reliability in harsh environments such as tunnels, plazas, industrial sites and infrastructure facilities.<\/p>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"5482\" data-end=\"5506\"><strong data-start=\"5482\" data-end=\"5506\">Typische Anwendungsbereiche<\/strong><\/p>\n<ul data-start=\"5508\" data-end=\"5899\">\n<li data-section-id=\"10h0a7k\" data-start=\"5508\" data-end=\"5550\">Large data centers and server facilities<\/li>\n<li data-section-id=\"dmzznz\" data-start=\"5551\" data-end=\"5599\">Industrial automation and manufacturing plants<\/li>\n<li data-section-id=\"1mn5mpb\" data-start=\"5600\" data-end=\"5652\">Telecom core networks and communication facilities<\/li>\n<li data-section-id=\"dk8qg1\" data-start=\"5653\" data-end=\"5703\">Hospitals and critical healthcare infrastructure<\/li>\n<li data-section-id=\"aiwgiw\" data-start=\"5704\" data-end=\"5756\">Transportation, tunnel and traffic-control systems<\/li>\n<li data-section-id=\"14xeilj\" data-start=\"5757\" data-end=\"5796\">Utility and infrastructure facilities<\/li>\n<li data-section-id=\"13izlhk\" data-start=\"5797\" data-end=\"5845\">Commercial buildings and large office campuses<\/li>\n<li data-section-id=\"1nqlak1\" data-start=\"5846\" data-end=\"5899\">Other mission-critical three-phase electrical loads<\/li>\n<\/ul>\n<h2>Technische Daten<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Modell<\/th>\n<td>EX3C3-180 kVA<\/td>\n<\/tr>\n<tr>\n<th>Kapazit\u00e4t<\/th>\n<td>180kVA \/ 180kW<\/td>\n<\/tr>\n<tr>\n<th>Topologie<\/th>\n<td>Online-USV mit Doppelwandlung<\/td>\n<\/tr>\n<tr>\n<th>Eingabephase<\/th>\n<td>Dreiphasig + Neutralleiter<\/td>\n<\/tr>\n<tr>\n<th>Eingangsspannungsbereich<\/th>\n<td>110 VAC (Ph-N) \u00b131 TP3T bei einer Last von 501 TP3T; 176 VAC (Ph-N) \u00b131 TP3T bei einer Last von 1001 TP3T<\/td>\n<\/tr>\n<tr>\n<th>Eingangsfrequenz<\/th>\n<td>50\/60 Hz, automatisch w\u00e4hlbar<\/td>\n<\/tr>\n<tr>\n<th>Eingangsleistungsfaktor<\/th>\n<td>&gt; 0,99 bei einer Belastung von 100%<\/td>\n<\/tr>\n<tr>\n<th>Ausgangsspannung<\/th>\n<td>380 \/ 400 \/ 415 VAC, dreiphasig<\/td>\n<\/tr>\n<tr>\n<th>Wechselspannungsregelung<\/th>\n<td>+\/-0.3%<\/td>\n<\/tr>\n<tr>\n<th>Ausgangsfrequenz<\/th>\n<td>46\u201354 Hz oder 56\u201364 Hz im Synchronbetrieb; 50 Hz \u00b10,1 Hz oder 60 Hz \u00b10,1 Hz im Batteriebetrieb<\/td>\n<\/tr>\n<tr>\n<th>Scheitelfaktor<\/th>\n<td>3:1<\/td>\n<\/tr>\n<tr>\n<th>Ausgangs-THD<\/th>\n<td>&lt;=1% bei linearer Belastung; &lt;=2% bei nichtlinearer Belastung<\/td>\n<\/tr>\n<tr>\n<th>\u00dcbertragungszeit<\/th>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<th>Effizienz<\/th>\n<td>&gt; 96,51 TP3T im Netzbetrieb; &gt; 96,51 TP3T im Batteriebetrieb<\/td>\n<\/tr>\n<tr>\n<th>Anzahl der Batterien<\/th>\n<td>32\u201340 St\u00fcck, verstellbar<\/td>\n<\/tr>\n<tr>\n<th>Ladestrom<\/th>\n<td>3-54A \u00b110%, voreingestellt auf 3 A<\/td>\n<\/tr>\n<tr>\n<th>Abmessungen<\/th>\n<td>1000 \u00d7 600 \u00d7 1200 mm<\/td>\n<\/tr>\n<tr>\n<th>Nettogewicht<\/th>\n<td>265 kg<\/td>\n<\/tr>\n<tr>\n<th>Betriebstemperatur<\/th>\n<td>0\u201340 \u00b0C<\/td>\n<\/tr>\n<tr>\n<th>Relative Luftfeuchtigkeit<\/th>\n<td>&lt; 95%, nicht kondensierend<\/td>\n<\/tr>\n<tr>\n<th>L\u00e4rm<\/th>\n<td>&lt; 75 dB in 1 m Entfernung<\/td>\n<\/tr>\n<tr>\n<th>Kommunikation<\/th>\n<td>RS232 \/ RS485 \/ USB, optional SNMP<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure id=\"attachment_2264\" class=\"wp-caption aligncenter\" style=\"width: 2400px;\" aria-describedby=\"caption-attachment-2264\">\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1q38h4v\" data-start=\"7755\" data-end=\"7810\">H\u00e4ufig gestellte Fragen:<br \/>\nWhat is the rated capacity of the EX3C3 180kVA UPS?<\/h3>\n<blockquote data-start=\"7812\" data-end=\"7882\">\n<p data-start=\"7814\" data-end=\"7882\">The EX3C3-180kVA reference configuration is rated at 180kVA \/ 180kW.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"98s6hi\" data-start=\"7884\" data-end=\"7924\">Is the EX3C3 180kVA a 3\/3 phase UPS?<\/h3>\n<blockquote data-start=\"7926\" data-end=\"8006\">\n<p data-start=\"7928\" data-end=\"8006\">Yes. It is designed for three-phase input and three-phase output applications.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1rytr2m\" data-start=\"8008\" data-end=\"8038\">What is the transfer time?<\/h3>\n<blockquote data-start=\"8040\" data-end=\"8133\">\n<p data-start=\"8042\" data-end=\"8133\">The reference specification lists 0ms transfer time for continuous online power protection.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"11oofti\" data-start=\"8135\" data-end=\"8187\">What output voltage does the 180kVA UPS support?<\/h3>\n<blockquote data-start=\"8189\" data-end=\"8262\">\n<p data-start=\"8191\" data-end=\"8262\">The reference configuration supports 380\/400\/415VAC three-phase output.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"dgnpvl\" data-start=\"8264\" data-end=\"8316\">Does the EX3C3 180kVA support remote monitoring?<\/h3>\n<blockquote data-start=\"8318\" data-end=\"8444\">\n<p data-start=\"8320\" data-end=\"8444\">Communication options include local interfaces and optional SNMP network management according to the selected configuration.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1g4jiu7\" data-start=\"8446\" data-end=\"8489\">How should battery runtime be selected?<\/h3>\n<blockquote data-start=\"8491\" data-end=\"8712\">\n<p data-start=\"8493\" data-end=\"8712\">Battery runtime depends on connected load, battery quantity and capacity, battery condition, temperature and required backup duration. DAXIN ENERGY can review the load and runtime requirements for project configuration.<\/p>\n<\/blockquote>\n<p><strong>What Is a 3\/3 Phase Online UPS?<\/strong><\/p>\n<p>A 3\/3 phase online UPS uses three-phase AC power at the input and supplies three-phase AC power at the output. This architecture is commonly used for high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and other large electrical installations.<\/p>\n<p>The DAXIN EX3C3 180kVA is designed for applications requiring high-capacity three-phase input and three-phase output power protection.<\/p>\n<p><figure id=\"attachment_4834\" aria-describedby=\"caption-attachment-4834\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4834\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs.webp\" alt=\"DAXIN EX3C3 10-200kVA 3\/3 Phase Online UPS Technical Specifications\" width=\"970\" height=\"958\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs.webp 970w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-300x296.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-768x758.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-12x12.webp 12w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/cs-100x100.webp 100w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><figcaption id=\"caption-attachment-4834\" class=\"wp-caption-text\">Technical specifications for DAXIN EX3C3 10-200kVA 3\/3 phase online UPS series.<\/figcaption><\/figure><figcaption id=\"caption-attachment-2264\" class=\"wp-caption-text\">Technical specifications for DAXIN ENERGY EX3C3 series three-phase online UPS, including the 180kVA model.<\/figcaption><\/figure>\n<figure id=\"attachment_2223\" class=\"wp-caption aligncenter\" style=\"width: 1200px;\" aria-describedby=\"caption-attachment-2223\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2223\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2260-detail-02.webp\" alt=\"DAXIN ENERGY EX3C3 180kVA Three-Phase Online UPS technical detail 2 by DAXIN ENERGY\" width=\"1200\" height=\"631\" \/><figcaption id=\"caption-attachment-2223\" class=\"wp-caption-text\">Social sharing image for DAXIN ENERGY 3H10kVA online UPS, designed for data centers, telecom power rooms and industrial backup power.<\/figcaption><\/figure>","protected":false},"excerpt":{"rendered":"<p>The DAXIN EX3C3 180kVA is a high-capacity 3\/3 phase online UPS designed for critical power applications requiring three-phase input and three-phase output. Featuring online double-conversion topology, 0ms transfer, &gt;96.5% efficiency, intelligent battery management and optional SNMP monitoring, it provides stable power protection for data centers, industrial facilities, telecom infrastructure, healthcare and transportation systems.<\/p>","protected":false},"featured_media":4835,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[46,622],"product_cat":[98,104],"product_tag":[],"class_list":["post-2260","product","type-product","status-publish","has-post-thumbnail","product_brand-szdxzh","product_brand-daxin-energy","product_cat-high-frequency-ups","product_cat-hf-3-3-phase-ups","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/product\/2260","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/comments?post=2260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/media\/4835"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/media?parent=2260"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/product_brand?post=2260"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/product_cat?post=2260"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/de\/wp-json\/wp\/v2\/product_tag?post=2260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}