Beschreibung
What Is the DAXIN RM33 300kVA Modular Online UPS?
The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large data centers, telecom facilities, industrial plants and other mission-critical power applications.
Its modular architecture integrates scalable power modules, centralized control, protection and service access within a common UPS platform, allowing installed capacity and redundancy to be planned according to the critical load and future expansion requirements.
The RM33-300kVA reference configuration provides 300kW cabinet capacity and supports 3 × 380/400/415VAC three-phase input and output, an input power factor of at least 0.99 at full load and external battery configurations.
Final power-module configuration, battery autonomy, redundancy architecture, bypass, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.
Wichtigste Vorteile
- 300kW Cabinet Capacity: Designed for large three-phase mission-critical power systems.
- Scalable Modular Architecture: Power-module configuration can be planned according to current load, redundancy requirements and future expansion.
- Three-Phase Online Power Protection: Supports 3 × 380/400/415VAC three-phase input and output.
- Hoher Eingangsleistungsfaktor: Input power factor is specified at ≥0.99 at full load and ≥0.98 at 50% load.
- External Battery Architecture: Battery capacity and backup autonomy can be engineered according to project requirements.
- Flexible Redundancy Planning: Modular architecture supports system designs based on required availability and future capacity growth.
- Network Management: Optional SNMP supports centralized UPS monitoring and power management.
- Large Critical-Power Applications: Suitable for data centers, telecom, industrial facilities and other high-availability infrastructure.
What Is a Modular UPS System?
A modular UPS system uses multiple power modules within a common UPS platform instead of relying on a single fixed-capacity power stage.
This architecture allows installed capacity, redundancy and future expansion to be planned according to the critical load and required system availability.
The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and optional network management for scalable critical-power applications.
How Should a 300kVA Modular UPS Be Sized?
A 300kVA modular UPS should be sized according to the actual critical load in both kW and kVA, load power factor, required redundancy, operating margin, expected future expansion and battery autonomy.
For large data center and industrial projects, system design should also consider power-module configuration, bypass architecture, upstream and downstream protection, generator compatibility, battery capacity, communications and maintenance requirements.
DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 modular UPS configuration.
Why Use a Modular UPS for Large Data Centers?
Modular UPS architecture allows data center operators to align installed power capacity with the actual critical load while preserving flexibility for redundancy and future expansion.
For growing facilities, additional capacity can be planned within the supported system architecture instead of treating every future load increase as a completely separate UPS project.
The DAXIN RM33 modular UPS platform is designed for scalable three-phase critical-power applications with external battery systems and network-management options.
DAXIN RM33-300kVA Key Specifications
| Parameter | Spezifikation |
|---|---|
| Modell | RM33-300kVA |
| UPS Type | Modular Online UPS |
| Phase | Three-Phase Input / Three-Phase Output |
| Cabinet Capacity | 300kW |
| Batterietyp | External Battery Pack |
| Single Battery Cabinet Capacity | 50kVA/60kVA (50kW/60kW) |
| Optional Battery Cabinets | 6 / 5 |
| Eingangsspannung | 3 × 380/400/415VAC (3PH+N) |
| Spannungsbereich | 110–300VAC @ 50% Load; 176–276VAC @ 100% Load |
| Rated Frequency | 50/60Hz Auto-Detect |
| Frequenzbereich | 40–70Hz |
| Eingangsleistungsfaktor | ≥0.99 @ 100% Load; ≥0.98 @ 50% Load |
| Input THDi | <4% @ 100% Load with 50kW Module |
| Ausgangsspannung | 3 × 380/400/415VAC (3PH+N) |
| Static Voltage Stability | ≤±1% Balanced; ≤±2% Unbalanced |
| Ausgangsfrequenz | 50–60Hz |
| Frequenzbereich | 46–54Hz or 56–64Hz |
| Ausgangs-THD | ≤2% Linear; ≤4% Non-linear |
| Effizienz | 95.5% with 50kW Module |
| Battery Voltage | ±192V to ±240V Optional |
| Max. Charge Current | 18A Adjustable per Battery Cabinet |
| Abmessungen | 1065 × 600 × 2010mm |
| Nettogewicht | 287 / 297kg |
| Betriebstemperatur | 0–40 °C |
| Relative Luftfeuchtigkeit | 0–95%, Non-Condensing |
| Höhe | <1000m at Rated Power |
| Schutzart | IP20 |
| Netzwerkmanagement | Optionales SNMP |

Control Panel and Front Detail for DAXIN RM33-300kVA Modular UPS System Cabinet.
Typische Anwendungsbereiche
- Large data centers and server facilities
- Telecom core networks and communication facilities
- Industrial automation and manufacturing plants
- Financial and banking infrastructure
- Healthcare and medical facilities
- Transportation and public infrastructure
- Enterprise IT and cloud infrastructure
- Other large mission-critical three-phase power systems
Auswahl und Projektplanung
Bitte überprüfen Sie vor der Bestellung die genauen Angaben zu Nennleistung, Eingangs-/Ausgangsphase, Spannung, Frequenz, Leistungsfaktor, Batteriespannung, Laufzeit, Bypass, Kommunikationsschnittstellen, Abmessungen, Umgebungsbedingungen und Installationsart anhand des ausgewählten Modells und der Projektzeichnungen.
Häufig gestellte Fragen
Kann dieses Produkt für ein bestimmtes Projekt angepasst werden?
Ja. Die elektrische Konfiguration, die Batterielaufzeit, die Kommunikationsfunktionen, der Bypass, die Gehäuseanordnung und das Projektzubehör können anhand der Anforderungen vor Ort überprüft werden.
Gelten alle technischen Bewertungen für die gesamte Serie?
Nein. Die Nennleistungen und Funktionen variieren je nach Modell und Konfiguration. Als maßgebliche Grundlage dient das projektspezifische technische Datenblatt.
Kann DAXIN ENERGY bei der Systemauswahl helfen?
Ja. Bitte geben Sie die Lastliste, die Phase und die Spannung, die erforderliche Laufzeit, das Redundanzziel, die Kommunikationsanforderungen und die Installationsumgebung an.
Projektkonfiguration anfordern
Senden Sie uns die Lastdaten, das Einliniendiagramm, die erforderliche Backup-Zeit und die Standortbedingungen, um ein maßgeschneidertes Angebot für eine USV oder Batterielösung zu erhalten.
What is the DAXIN RM33 300kVA?
The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large scalable critical-power applications.
What is the cabinet capacity?
The RM33-300kVA reference configuration specifies 300kW cabinet capacity.
What input and output voltage does it support?
The reference specification lists 3 × 380/400/415VAC three-phase input and output.
What is the input power factor?
The specification lists an input power factor of at least 0.99 at 100% load and at least 0.98 at 50% load.
Does the RM33 support external batteries?
Yes. The RM33-300kVA uses an external battery architecture, with final battery capacity and runtime engineered according to project requirements.
Can the RM33-300kVA support remote monitoring?
Yes. Optional SNMP network management is available for centralized power monitoring and management.







Rezensionen