{"id":3030,"date":"2026-08-02T23:29:54","date_gmt":"2026-08-02T15:29:54","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3030"},"modified":"2026-08-17T18:28:16","modified_gmt":"2026-08-17T10:28:16","slug":"daxin-rm33-180kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/ar\/product\/daxin-rm33-180kva-system-ups\/","title":{"rendered":"\u0645\u0635\u062f\u0631 \u0637\u0627\u0642\u0629 \u063a\u064a\u0631 \u0645\u0646\u0642\u0637\u0639 (UPS) \u0645\u0639\u064a\u0627\u0631\u064a \u0645\u062a\u0635\u0644 \u0645\u0628\u0627\u0634\u0631\u0629 \u0628\u062a\u064a\u0627\u0631 \u0627\u0644\u0634\u0628\u0643\u0629\u060c \u0628\u0642\u062f\u0631\u0629 180 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631 | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 180kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.<\/p>\n<p>Its modular cabinet architecture integrates power modules, centralized control, protection and service access within a scalable UPS platform, allowing installed capacity and redundancy to be configured according to project requirements.<\/p>\n<p>\u062a\u062f\u0639\u0645 \u0633\u0644\u0633\u0644\u0629 RM33 \u0645\u062f\u062e\u0644\u0627\u062a \u0648\u0645\u062e\u0631\u062c\u0627\u062a \u062b\u0644\u0627\u062b\u064a\u0629 \u0627\u0644\u0637\u0648\u0631 \u0628\u0642\u064a\u0645 3 \u00d7 380\/400\/415 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f\u060c \u0648\u0639\u0627\u0645\u0644 \u0642\u062f\u0631\u0629 \u0645\u062f\u062e\u0644\u0627\u062a \u0644\u0627 \u064a\u0642\u0644 \u0639\u0646 0.99 \u0639\u0646\u062f \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0643\u0627\u0645\u0644\u060c \u0648\u0645\u0624\u0634\u0631 \u0627\u0644\u062a\u0634\u0648\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0627\u0644\u0643\u0644\u064a (THDi) \u0644\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u062f\u062e\u0644 \u0623\u0642\u0644 \u0645\u0646 2%\u060c \u0648\u0643\u0641\u0627\u0621\u0629 \u0646\u0638\u0627\u0645 \u062a\u0635\u0644 \u0625\u0644\u0649 96.5%.<\/p>\n<p>Battery configuration, backup runtime, redundancy architecture, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.<br \/>\n<strong>DAXIN RM33-180kVA Key Specifications<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u0627\u0644\u0637\u0631\u0627\u0632<\/strong><\/td>\n<td><strong>RM33-180kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 UPS<\/td>\n<td>\u0648\u062d\u062f\u0629 \u062a\u0632\u0648\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u063a\u064a\u0631 \u0627\u0644\u0645\u0646\u0642\u0637\u0639\u0629 (UPS) \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0639\u0628\u0631 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0645\u0631\u062d\u0644\u0629<\/td>\n<td>\u0645\u062f\u062e\u0644 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \/ \u0645\u062e\u0631\u062c \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0633\u0639\u0629 \u0627\u0644\u062e\u0632\u0627\u0646\u0629<\/td>\n<td><strong>180kW or 120kW configuration<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629<\/td>\n<td>\u062d\u0632\u0645\u0629 \u0628\u0637\u0627\u0631\u064a\u0629 \u062e\u0627\u0631\u062c\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0633\u0639\u0629 \u062e\u0632\u0627\u0646\u0629 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0627\u062a<\/td>\n<td>30 \u0643\u064a\u0644\u0648 \u0641\u0648\u0644\u062a \u0623\u0645\u0628\u064a\u0631 \/ 30 \u0643\u064a\u0644\u0648\u0648\u0627\u0637<\/td>\n<\/tr>\n<tr>\n<td>\u062e\u0632\u0627\u0646\u0627\u062a \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629<\/td>\n<td>Up to 6<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u062f \u0627\u0644\u062f\u062e\u0644<\/td>\n<td>3 \u00d7 380\/400\/415 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f (\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 + N)<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0631\u062f\u062f \u0627\u0644\u0625\u062f\u062e\u0627\u0644<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632\u060c \u0627\u0644\u0643\u0634\u0641 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0637\u0627\u0642 \u062a\u0631\u062f\u062f \u0627\u0644\u0625\u062f\u062e\u0627\u0644<\/td>\n<td>40\u201370 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u062f\u062e\u0644\u0629<\/td>\n<td>\u22650.99 \u0639\u0646\u062f \u062d\u0645\u0644 100%<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0634\u0648\u064a\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0627\u0644\u0643\u0644\u064a \u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u062e\u0644 (THDi)<\/td>\n<td>&lt;2% @ 100% \u0627\u0644\u062d\u0645\u0644<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u062f \u0627\u0644\u062e\u0631\u062c<\/td>\n<td>3 \u00d7 380\/400\/415 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f (\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 + N)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0633\u0627\u0643\u0646<\/td>\n<td>\u2264\u00b10.3% \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u062f\u064a\u0646\u0627\u0645\u064a\u0643\u064a<\/td>\n<td>\u2264\u00b13% \u0627\u0644\u062d\u0645\u0648\u0644\u0629 \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0631\u062f\u062f \u0627\u0644\u062e\u0631\u062c<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0637\u0627\u0642 \u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td>46\u201354Hz or 56\u201364Hz<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0634\u0648\u064a\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0627\u0644\u0643\u0644\u064a (THD) \u0641\u064a \u0627\u0644\u062e\u0631\u062c<\/td>\n<td>\u22641% \u062e\u0637\u064a \/ \u22642% \u063a\u064a\u0631 \u062e\u0637\u064a<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0643\u0641\u0627\u0621\u0629<\/td>\n<td><strong>\u0645\u0627 \u064a\u0635\u0644 \u0625\u0644\u0649 96.5%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/td>\n<td><strong>1100 \u00d7 600 \u00d7 1475mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0648\u0632\u0646 \u0627\u0644\u0635\u0627\u0641\u064a<\/td>\n<td><strong>195 \/ 223kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>0\u201340 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639<\/td>\n<td>&lt;1000m at Rated Power<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0648\u0627\u0635\u0644<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0634\u0628\u0643\u0629<\/td>\n<td>SNMP \u0627\u062e\u062a\u064a\u0627\u0631\u064a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2>\u0627\u0644\u0645\u0632\u0627\u064a\u0627 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li><strong>180kVA Modular UPS Platform:<\/strong>\u00a0Designed for scalable three-phase critical-power applications in data centers, telecom and industrial facilities.<\/li>\n<li><strong>\u0628\u0646\u064a\u0629 \u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0648\u0633\u0639:<\/strong>\u00a0Power-module configuration can be planned according to current load, redundancy requirements and future expansion.<\/li>\n<li><strong>\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/li>\n<li><strong>\u0627\u0646\u062e\u0641\u0627\u0636 \u062a\u0634\u0648\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0641\u064a \u0627\u0644\u0625\u062f\u062e\u0627\u0644:<\/strong>\u00a0\u064a\u0633\u0627\u0639\u062f \u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u0634\u0648\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0627\u0644\u0643\u0644\u064a (THDi) \u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0625\u062f\u062e\u0627\u0644 \u0627\u0644\u0630\u064a \u064a\u0642\u0644 \u0639\u0646 2% \u0639\u0646\u062f \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0643\u0627\u0645\u0644 \u0639\u0644\u0649 \u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u062a\u0623\u062b\u064a\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0639\u0644\u0649 \u0627\u0644\u0634\u0628\u0643\u0629.<\/li>\n<li><strong>\u0645\u0639\u0627\u0645\u0644 \u0642\u062f\u0631\u0629 \u0645\u062f\u062e\u0644\u0627\u062a \u0639\u0627\u0644\u064a:<\/strong>\u00a0\u064a\u0628\u0644\u063a \u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0646\u062f \u0627\u0644\u062f\u062e\u0644 0.99 \u0639\u0644\u0649 \u0627\u0644\u0623\u0642\u0644 \u0639\u0646\u062f \u062d\u0645\u0644 100%.<\/li>\n<li><strong>\u0643\u0641\u0627\u0621\u0629 \u0639\u0627\u0644\u064a\u0629:<\/strong>\u00a0\u062a\u0628\u0644\u063a \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0646\u0638\u0627\u0645 \u0645\u0627 \u064a\u0635\u0644 \u0625\u0644\u0649 96.51 TP3T.<\/li>\n<li><strong>\u0625\u0639\u062f\u0627\u062f\u0627\u062a \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629 \u0627\u0644\u062e\u0627\u0631\u062c\u064a\u0629:<\/strong>\u00a0Battery capacity and backup runtime can be engineered according to project requirements.<\/li>\n<li><strong>\u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f:<\/strong>\u00a0\u064a\u062a\u0645 \u062f\u0639\u0645 \u0627\u0644\u0627\u062a\u0635\u0627\u0644 \u0639\u0628\u0631 RS-232\/USB\u060c \u0645\u0639 \u0625\u0645\u0643\u0627\u0646\u064a\u0629 \u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0634\u0628\u0643\u0629 \u0639\u0628\u0631 \u0628\u0631\u0648\u062a\u0648\u0643\u0648\u0644 SNMP \u0628\u0634\u0643\u0644 \u0627\u062e\u062a\u064a\u0627\u0631\u064a.<\/li>\n<\/ul>\n<h2>\u0645\u0627 \u0647\u0648 \u0646\u0638\u0627\u0645 UPS \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u061f<\/h2>\n<p>A modular UPS system uses multiple power modules within a common UPS cabinet instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This architecture allows capacity, redundancy and maintenance strategy to be planned according to the critical load, required availability and future expansion.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and network-management options for scalable critical-power applications.<\/p>\n<h2>How Should an 180kVA Modular UPS Be Sized?<\/h2>\n<p>An 180kVA modular UPS should be sized according to the actual critical load in kW and kVA, load power factor, required redundancy, expected future expansion and battery autonomy.<\/p>\n<p>Modular system design should also consider the number and rating of installed power modules, bypass architecture, upstream and downstream protection, communication requirements and maintenance strategy.<\/p>\n<p>DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 system configuration.<\/p>\n<h2>\u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0639\u0646 \u0627\u0644\u0645\u0646\u062a\u062c \u0648\u0627\u0644\u0645\u0631\u0627\u062c\u0639 \u0627\u0644\u0641\u0646\u064a\u0629<\/h2>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4939\" aria-describedby=\"caption-attachment-4939\" style=\"width: 812px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4939\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp\" alt=\"\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0644\u0645\u0632\u0648\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u063a\u064a\u0631 \u0627\u0644\u0645\u0646\u0642\u0637\u0639\u0629 (UPS) \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a \u0627\u0644\u0645\u062a\u0635\u0644 \u0628\u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a DAXIN RM33\" width=\"812\" height=\"1935\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp 812w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-126x300.webp 126w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-430x1024.webp 430w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-768x1830.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-645x1536.webp 645w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-5x12.webp 5w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><figcaption id=\"caption-attachment-4939\" class=\"wp-caption-text\">\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0644\u0633\u0644\u0633\u0644\u0629 \u0623\u062c\u0647\u0632\u0629 UPS \u062b\u0644\u0627\u062b\u064a\u0629 \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0645\u0646 \u0637\u0631\u0627\u0632 DAXIN RM33 \u0627\u0644\u062a\u064a \u062a\u0639\u0645\u0644 \u0641\u064a \u0648\u0636\u0639 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0628\u0627\u0634\u0631.<\/figcaption><\/figure><figcaption>Product Close-Up for DAXIN RM33-180kVA Modular UPS System Cabinet.<\/figcaption><\/figure>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/h2>\n<ul>\n<li>\u0645\u0631\u0627\u0643\u0632 \u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0648\u063a\u0631\u0641 \u0627\u0644\u062e\u0648\u0627\u062f\u0645<\/li>\n<li>\u0627\u0644\u0645\u0631\u0627\u0641\u0642 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u0629 \u0644\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a \u0648\u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0644\u0644\u0634\u0628\u0643\u0629<\/li>\n<li>\u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/li>\n<li>\u0627\u0644\u062e\u062f\u0645\u0627\u062a \u0627\u0644\u0645\u0627\u0644\u064a\u0629 \u0648\u0627\u0644\u0645\u0635\u0631\u0641\u064a\u0629<\/li>\n<li>\u0627\u0644\u0631\u0639\u0627\u064a\u0629 \u0627\u0644\u0635\u062d\u064a\u0629 \u0648\u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0627\u0644\u0637\u0628\u064a\u0629<\/li>\n<li>\u0627\u0644\u0646\u0642\u0644 \u0648\u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0627\u0644\u0639\u0627\u0645\u0629<\/li>\n<li>\u0645\u0631\u0627\u0641\u0642 \u062a\u0643\u0646\u0648\u0644\u0648\u062c\u064a\u0627 \u0627\u0644\u0645\u0639\u0644\u0648\u0645\u0627\u062a \u0627\u0644\u0645\u0624\u0633\u0633\u064a\u0629<\/li>\n<li>\u0623\u0646\u0638\u0645\u0629 \u0637\u0627\u0642\u0629 \u0623\u062e\u0631\u0649 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0648\u0633\u0639 \u0648\u0630\u0627\u062a \u0623\u0647\u0645\u064a\u0629 \u062d\u0627\u0633\u0645\u0629 \u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0645\u0647\u0627\u0645<\/li>\n<\/ul>\n<h2>\u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0648\u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639<\/h2>\n<p>\u064a\u0631\u062c\u0649 \u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0627\u0644\u0642\u0648\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062f\u0642\u064a\u0642\u0629\u060c \u0648\u0637\u0648\u0631 \u0627\u0644\u062f\u062e\u0644\/\u0627\u0644\u062e\u0631\u062c\u060c \u0648\u0627\u0644\u062c\u0647\u062f\u060c \u0648\u0627\u0644\u062a\u0631\u062f\u062f\u060c \u0648\u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629\u060c \u0648\u062c\u0647\u062f \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629\u060c \u0648\u0645\u062f\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0648\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062c\u0627\u0648\u0632\u060c \u0648\u0648\u0633\u0627\u0626\u0644 \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u060c \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f\u060c \u0648\u0627\u0644\u062d\u062f\u0648\u062f \u0627\u0644\u0628\u064a\u0626\u064a\u0629\u060c \u0648\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u060c \u0645\u0642\u0627\u0631\u0646\u0629\u064b \u0628\u0627\u0644\u0637\u0631\u0627\u0632 \u0627\u0644\u0645\u062e\u062a\u0627\u0631 \u0648\u0631\u0633\u0648\u0645\u0627\u062a \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0642\u0628\u0644 \u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u0637\u0644\u0628.<\/p>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3>\u0647\u0644 \u064a\u0645\u0643\u0646 \u062a\u062e\u0635\u064a\u0635 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c \u0644\u0645\u0634\u0631\u0648\u0639 \u0645\u0639\u064a\u0646\u061f<\/h3>\n<p>\u0646\u0639\u0645. \u064a\u0645\u0643\u0646 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0645\u062f\u0629 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629\u060c \u0648\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a\u060c \u0648\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062c\u0627\u0648\u0632\u060c \u0648\u062a\u0631\u062a\u064a\u0628 \u0627\u0644\u062e\u0632\u0627\u0646\u0627\u062a\u060c \u0648\u0645\u0644\u062d\u0642\u0627\u062a \u0627\u0644\u0645\u0634\u0631\u0648\u0639\u060c \u0648\u0641\u0642\u064b\u0627 \u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u0648\u0642\u0639.<\/p>\n<h3>\u0647\u0644 \u064a\u062a\u0645 \u062a\u0637\u0628\u064a\u0642 \u062c\u0645\u064a\u0639 \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u0633\u0644\u0633\u0644\u0629 \u0628\u0623\u0643\u0645\u0644\u0647\u0627\u061f<\/h3>\n<p>\u0644\u0627. \u062a\u062e\u062a\u0644\u0641 \u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u064a\u0629 \u0648\u0627\u0644\u0648\u0638\u0627\u0626\u0641 \u0628\u0627\u062e\u062a\u0644\u0627\u0641 \u0627\u0644\u0637\u0631\u0627\u0632 \u0648\u0627\u0644\u062a\u0643\u0648\u064a\u0646. \u064a\u0631\u062c\u0649 \u0627\u0644\u0627\u0639\u062a\u0645\u0627\u062f \u0639\u0644\u0649 \u0648\u0631\u0642\u0629 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0643\u0645\u0631\u062c\u0639 \u0646\u0647\u0627\u0626\u064a.<\/p>\n<h3>\u0647\u0644 \u064a\u0645\u0643\u0646 \u0644\u0634\u0631\u0643\u0629 \u00ab\u062f\u0627\u0643\u0633\u064a\u0646 \u0625\u0646\u064a\u0631\u062c\u064a\u00bb \u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u062f\u0639\u0645 \u0641\u064a \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0646\u0638\u0627\u0645\u061f<\/h3>\n<p>\u0646\u0639\u0645. \u064a\u0631\u062c\u0649 \u062a\u0642\u062f\u064a\u0645 \u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0623\u062d\u0645\u0627\u0644\u060c \u0648\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0637\u0648\u0631 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0645\u062f\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629\u060c \u0648\u0627\u0644\u0647\u062f\u0641 \u0627\u0644\u0645\u062d\u062f\u062f \u0644\u0644\u062a\u0643\u0631\u0627\u0631\u060c \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u060c \u0648\u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628.<\/p>\n<h3>\u0637\u0644\u0628 \u062a\u0643\u0648\u064a\u0646 \u0645\u0634\u0631\u0648\u0639<\/h3>\n<p>\u064a\u0631\u062c\u0649 \u0625\u0631\u0633\u0627\u0644 \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062d\u0645\u0644\u060c \u0648\u0627\u0644\u0631\u0633\u0645 \u0627\u0644\u062a\u062e\u0637\u064a\u0637\u064a \u0623\u062d\u0627\u062f\u064a \u0627\u0644\u062e\u0637\u060c \u0648\u0648\u0642\u062a \u0627\u0644\u0646\u0633\u062e \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u060c \u0648\u0638\u0631\u0648\u0641 \u0627\u0644\u0645\u0648\u0642\u0639 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0645\u062e\u0635\u0635 \u0644\u062c\u0647\u0627\u0632 UPS \u0623\u0648 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0627\u062a.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"10vliy8\" data-start=\"8494\" data-end=\"8528\">What is the DAXIN RM33 180kVA?<\/h3>\n<p data-start=\"8530\" data-end=\"8649\">The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power applications.<\/p>\n<h3 data-section-id=\"zp921o\" data-start=\"8651\" data-end=\"8701\">\u0645\u0627 \u0647\u064a \u0642\u064a\u0645 \u062c\u0647\u062f \u0627\u0644\u062f\u062e\u0644 \u0648\u0627\u0644\u062e\u0631\u0648\u062c \u0627\u0644\u062a\u064a \u064a\u062f\u0639\u0645\u0647\u0627 \u0647\u0630\u0627 \u0627\u0644\u062c\u0647\u0627\u0632\u061f<\/h3>\n<p data-start=\"8703\" data-end=\"8789\">\u062a\u064f\u062f\u0631\u062c \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0645\u0631\u062c\u0639\u064a\u0629 \u0645\u062f\u062e\u0644\u0627\u062a \u0648\u0645\u062e\u0631\u062c\u0627\u062a \u062b\u0644\u0627\u062b\u064a\u0629 \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u0628\u0642\u062f\u0631\u0629 3 \u00d7 380\/400\/415 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f.<\/p>\n<h3 data-section-id=\"18hlpeq\" data-start=\"8791\" data-end=\"8836\">\u0645\u0627 \u0647\u0648 \u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u062f\u062e\u0644\u0629 \u0648\u0645\u0624\u0634\u0631 \u0627\u0644\u062a\u0647\u064a\u062f\u0631\u0648\u0644\u064a\u0643\u064a\u0629 \u0627\u0644\u0643\u0644\u064a\u0629 (THDi)\u061f<\/h3>\n<p data-start=\"8838\" data-end=\"8965\">The RM33 reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.<\/p>\n<h3 data-section-id=\"196h0qa\" data-start=\"8967\" data-end=\"9018\">What is the efficiency of the RM33 modular UPS?<\/h3>\n<p data-start=\"9020\" data-end=\"9148\">The reference specification lists system efficiency up to 96.5%. Actual efficiency depends on load and system configuration.<\/p>\n<h3 data-section-id=\"1xhhnr9\" data-start=\"9150\" data-end=\"9194\">\u0647\u0644 \u064a\u062f\u0639\u0645 \u062c\u0647\u0627\u0632 RM33 \u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f\u061f<\/h3>\n<p data-start=\"9196\" data-end=\"9282\">Yes. RS-232\/USB communication is supported, with optional SNMP network management.<\/p>\n<h3 data-section-id=\"610dx3\" data-start=\"9284\" data-end=\"9344\">Can the RM33-180kVA system be configured for redundancy?<\/h3>\n<p data-start=\"9346\" data-end=\"9571\">Yes, modular architecture allows redundancy requirements to be considered during system design. Final module quantity, redundancy architecture and installed capacity should be confirmed in the approved technical proposal.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. Its modular architecture supports flexible capacity planning, centralized control, external battery configurations and optional SNMP monitoring, with system efficiency up to 96.5%.<\/p>","protected":false},"featured_media":4945,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3030","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product\/3030","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/comments?post=3030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/media\/4945"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/media?parent=3030"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product_brand?post=3030"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product_cat?post=3030"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product_tag?post=3030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}