{"id":3010,"date":"2026-08-02T15:27:43","date_gmt":"2026-08-02T15:27:43","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3010"},"modified":"2026-08-17T20:23:53","modified_gmt":"2026-08-17T12:23:53","slug":"daxin-rm33-300kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/ar\/product\/daxin-rm33-300kva-system-ups\/","title":{"rendered":"300kVA Modular Online UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 300kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large data centers, telecom facilities, industrial plants and other mission-critical power applications.<\/p>\n<p>Its modular architecture integrates scalable power modules, centralized control, protection and service access within a common UPS platform, allowing installed capacity and redundancy to be planned according to the critical load and future expansion requirements.<\/p>\n<p>The RM33-300kVA reference configuration provides 300kW cabinet capacity and supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load and external battery configurations.<\/p>\n<p>Final power-module configuration, battery autonomy, redundancy architecture, bypass, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.<\/p>\n<h2>\u0627\u0644\u0645\u0632\u0627\u064a\u0627 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li><strong>300kW Cabinet Capacity:<\/strong>\u00a0Designed for large three-phase mission-critical power systems.<\/li>\n<li><strong>\u0628\u0646\u064a\u0629 \u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0642\u0627\u0628\u0644\u0629 \u0644\u0644\u062a\u0648\u0633\u0639:<\/strong>\u00a0Power-module configuration can be planned according to current load, redundancy requirements and future expansion.<\/li>\n<li><strong>Three-Phase Online Power Protection:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/li>\n<li><strong>\u0645\u0639\u0627\u0645\u0644 \u0642\u062f\u0631\u0629 \u0645\u062f\u062e\u0644\u0627\u062a \u0639\u0627\u0644\u064a:<\/strong>\u00a0Input power factor is specified at \u22650.99 at full load and \u22650.98 at 50% load.<\/li>\n<li><strong>External Battery Architecture:<\/strong>\u00a0Battery capacity and backup autonomy can be engineered according to project requirements.<\/li>\n<li><strong>Flexible Redundancy Planning:<\/strong>\u00a0Modular architecture supports system designs based on required availability and future capacity growth.<\/li>\n<li><strong>Network Management:<\/strong>\u00a0Optional SNMP supports centralized UPS monitoring and power management.<\/li>\n<li><strong>Large Critical-Power Applications:<\/strong>\u00a0Suitable for data centers, telecom, industrial facilities and other high-availability infrastructure.<\/li>\n<\/ul>\n<h2>\u0645\u0627 \u0647\u0648 \u0646\u0638\u0627\u0645 UPS \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u061f<\/h2>\n<p>A modular UPS system uses multiple power modules within a common UPS platform instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This architecture allows installed capacity, redundancy and future expansion to be planned according to the critical load and required system availability.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and optional network management for scalable critical-power applications.<\/p>\n<h2>How Should a 300kVA Modular UPS Be Sized?<\/h2>\n<p>A 300kVA modular UPS should be sized according to the actual critical load in both kW and kVA, load power factor, required redundancy, operating margin, expected future expansion and battery autonomy.<\/p>\n<p>For large data center and industrial projects, system design should also consider power-module configuration, bypass architecture, upstream and downstream protection, generator compatibility, battery capacity, communications and maintenance requirements.<\/p>\n<p>DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 modular UPS configuration.<\/p>\n<h2>Why Use a Modular UPS for Large Data Centers?<\/h2>\n<p>Modular UPS architecture allows data center operators to align installed power capacity with the actual critical load while preserving flexibility for redundancy and future expansion.<\/p>\n<p>For growing facilities, additional capacity can be planned within the supported system architecture instead of treating every future load increase as a completely separate UPS project.<\/p>\n<p>The DAXIN RM33 modular UPS platform is designed for scalable three-phase critical-power applications with external battery systems and network-management options.<\/p>\n<h2>\nDAXIN RM33-300kVA Key Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u0627\u0644\u0637\u0631\u0627\u0632<\/strong><\/td>\n<td><strong>RM33-300kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 UPS<\/td>\n<td>\u0648\u062d\u062f\u0629 \u062a\u0632\u0648\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u063a\u064a\u0631 \u0627\u0644\u0645\u0646\u0642\u0637\u0639\u0629 (UPS) \u0627\u0644\u0645\u0639\u064a\u0627\u0631\u064a\u0629 \u0639\u0628\u0631 \u0627\u0644\u0625\u0646\u062a\u0631\u0646\u062a<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0645\u0631\u062d\u0644\u0629<\/td>\n<td>\u0645\u062f\u062e\u0644 \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \/ \u0645\u062e\u0631\u062c \u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0633\u0639\u0629 \u0627\u0644\u062e\u0632\u0627\u0646\u0629<\/td>\n<td><strong>300kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629<\/td>\n<td>\u062d\u0632\u0645\u0629 \u0628\u0637\u0627\u0631\u064a\u0629 \u062e\u0627\u0631\u062c\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>Single Battery Cabinet Capacity<\/td>\n<td>50kVA\/60kVA (50kW\/60kW)<\/td>\n<\/tr>\n<tr>\n<td>\u062e\u0632\u0627\u0646\u0627\u062a \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0627\u062a \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629<\/td>\n<td>6 \/ 5<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u062f \u0627\u0644\u062f\u062e\u0644<\/td>\n<td>3 \u00d7 380\/400\/415 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f (\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 + N)<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0637\u0627\u0642 \u0627\u0644\u062c\u0647\u062f<\/td>\n<td>110\u2013300VAC @ 50% Load; 176\u2013276VAC @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Rated Frequency<\/td>\n<td>50\/60 \u0647\u0631\u062a\u0632\u060c \u0627\u0644\u0643\u0634\u0641 \u0627\u0644\u062a\u0644\u0642\u0627\u0626\u064a<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0637\u0627\u0642 \u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td>40\u201370 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u0645\u062f\u062e\u0644\u0629<\/td>\n<td>\u22650.99 @ 100% Load; \u22650.98 @ 50% Load<\/td>\n<\/tr>\n<tr>\n<td>Input THDi<\/td>\n<td>&lt;4% @ 100% Load with 50kW Module<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u062f \u0627\u0644\u062e\u0631\u062c<\/td>\n<td>3 \u00d7 380\/400\/415 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f (\u062b\u0644\u0627\u062b\u064a \u0627\u0644\u0623\u0637\u0648\u0627\u0631 + N)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0633\u062a\u0642\u0631\u0627\u0631 \u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0633\u0627\u0643\u0646<\/td>\n<td>\u2264\u00b11% Balanced; \u2264\u00b12% Unbalanced<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0631\u062f\u062f \u0627\u0644\u062e\u0631\u062c<\/td>\n<td>50\u201360Hz<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0637\u0627\u0642 \u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td>46\u201354Hz or 56\u201364Hz<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0634\u0648\u064a\u0647 \u0627\u0644\u062a\u0648\u0627\u0641\u0642\u064a \u0627\u0644\u0643\u0644\u064a (THD) \u0641\u064a \u0627\u0644\u062e\u0631\u062c<\/td>\n<td>\u22642% Linear; \u22644% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0643\u0641\u0627\u0621\u0629<\/td>\n<td><strong>95.5% with 50kW Module<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Battery Voltage<\/td>\n<td>\u00b1192V to \u00b1240V Optional<\/td>\n<\/tr>\n<tr>\n<td>Max. Charge Current<\/td>\n<td>18A Adjustable per Battery Cabinet<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/td>\n<td><strong>1065 \u00d7 600 \u00d7 2010mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0648\u0632\u0646 \u0627\u0644\u0635\u0627\u0641\u064a<\/td>\n<td><strong>287 \/ 297kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>0\u201340 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0631\u0637\u0648\u0628\u0629 \u0627\u0644\u0646\u0633\u0628\u064a\u0629<\/td>\n<td>0\u201395%, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639<\/td>\n<td>&lt;1000m at Rated Power<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>\u0625\u062f\u0627\u0631\u0629 \u0627\u0644\u0634\u0628\u0643\u0629<\/td>\n<td>SNMP \u0627\u062e\u062a\u064a\u0627\u0631\u064a<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\"><figcaption>\n<figure id=\"attachment_4953\" aria-describedby=\"caption-attachment-4953\" style=\"width: 836px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4953\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp\" alt=\"DAXIN RM33 60-600kVA Modular Online UPS Technical Specifications\" width=\"836\" height=\"1880\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp 836w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-133x300.webp 133w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-455x1024.webp 455w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-768x1727.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-683x1536.webp 683w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-5x12.webp 5w\" sizes=\"auto, (max-width: 836px) 100vw, 836px\" \/><figcaption id=\"caption-attachment-4953\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 60-600kVA three-phase modular online UPS series.<\/figcaption><\/figure>\n<p>Control Panel and Front Detail for DAXIN RM33-300kVA Modular UPS System Cabinet.<\/p>\n<\/figcaption><\/figure>\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a \u0627\u0644\u0646\u0645\u0648\u0630\u062c\u064a\u0629<\/h2>\n<ul>\n<li>Large data centers and server facilities<\/li>\n<li>Telecom core networks and communication facilities<\/li>\n<li>\u0627\u0644\u0623\u062a\u0645\u062a\u0629 \u0627\u0644\u0635\u0646\u0627\u0639\u064a\u0629 \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0625\u0646\u062a\u0627\u062c<\/li>\n<li>Financial and banking infrastructure<\/li>\n<li>Healthcare and medical facilities<\/li>\n<li>\u0627\u0644\u0646\u0642\u0644 \u0648\u0627\u0644\u0628\u0646\u064a\u0629 \u0627\u0644\u062a\u062d\u062a\u064a\u0629 \u0627\u0644\u0639\u0627\u0645\u0629<\/li>\n<li>Enterprise IT and cloud infrastructure<\/li>\n<li>Other large mission-critical three-phase power systems<\/li>\n<\/ul>\n<h2>\u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631 \u0648\u062a\u062e\u0637\u064a\u0637 \u0627\u0644\u0645\u0634\u0627\u0631\u064a\u0639<\/h2>\n<p>\u064a\u0631\u062c\u0649 \u0627\u0644\u062a\u0623\u0643\u062f \u0645\u0646 \u0627\u0644\u0642\u0648\u0629 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u0629 \u0627\u0644\u062f\u0642\u064a\u0642\u0629\u060c \u0648\u0637\u0648\u0631 \u0627\u0644\u062f\u062e\u0644\/\u0627\u0644\u062e\u0631\u062c\u060c \u0648\u0627\u0644\u062c\u0647\u062f\u060c \u0648\u0627\u0644\u062a\u0631\u062f\u062f\u060c \u0648\u0645\u0639\u0627\u0645\u0644 \u0627\u0644\u0642\u062f\u0631\u0629\u060c \u0648\u062c\u0647\u062f \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629\u060c \u0648\u0645\u062f\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0648\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062c\u0627\u0648\u0632\u060c \u0648\u0648\u0633\u0627\u0626\u0644 \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u060c \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f\u060c \u0648\u0627\u0644\u062d\u062f\u0648\u062f \u0627\u0644\u0628\u064a\u0626\u064a\u0629\u060c \u0648\u0637\u0631\u064a\u0642\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628\u060c \u0645\u0642\u0627\u0631\u0646\u0629\u064b \u0628\u0627\u0644\u0637\u0631\u0627\u0632 \u0627\u0644\u0645\u062e\u062a\u0627\u0631 \u0648\u0631\u0633\u0648\u0645\u0627\u062a \u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0642\u0628\u0644 \u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u0637\u0644\u0628.<\/p>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3>\u0647\u0644 \u064a\u0645\u0643\u0646 \u062a\u062e\u0635\u064a\u0635 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c \u0644\u0645\u0634\u0631\u0648\u0639 \u0645\u0639\u064a\u0646\u061f<\/h3>\n<p>\u0646\u0639\u0645. \u064a\u0645\u0643\u0646 \u0645\u0631\u0627\u062c\u0639\u0629 \u0627\u0644\u062a\u0643\u0648\u064a\u0646 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0645\u062f\u0629 \u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0629\u060c \u0648\u0623\u0646\u0638\u0645\u0629 \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u0627\u062a\u060c \u0648\u0646\u0638\u0627\u0645 \u0627\u0644\u062a\u062c\u0627\u0648\u0632\u060c \u0648\u062a\u0631\u062a\u064a\u0628 \u0627\u0644\u062e\u0632\u0627\u0646\u0627\u062a\u060c \u0648\u0645\u0644\u062d\u0642\u0627\u062a \u0627\u0644\u0645\u0634\u0631\u0648\u0639\u060c \u0648\u0641\u0642\u064b\u0627 \u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0645\u0648\u0642\u0639.<\/p>\n<h3>\u0647\u0644 \u064a\u062a\u0645 \u062a\u0637\u0628\u064a\u0642 \u062c\u0645\u064a\u0639 \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0639\u0644\u0649 \u0627\u0644\u0633\u0644\u0633\u0644\u0629 \u0628\u0623\u0643\u0645\u0644\u0647\u0627\u061f<\/h3>\n<p>\u0644\u0627. \u062a\u062e\u062a\u0644\u0641 \u0627\u0644\u0642\u064a\u0645 \u0627\u0644\u062a\u0635\u0646\u064a\u0641\u064a\u0629 \u0648\u0627\u0644\u0648\u0638\u0627\u0626\u0641 \u0628\u0627\u062e\u062a\u0644\u0627\u0641 \u0627\u0644\u0637\u0631\u0627\u0632 \u0648\u0627\u0644\u062a\u0643\u0648\u064a\u0646. \u064a\u0631\u062c\u0649 \u0627\u0644\u0627\u0639\u062a\u0645\u0627\u062f \u0639\u0644\u0649 \u0648\u0631\u0642\u0629 \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0627\u0644\u0645\u0634\u0631\u0648\u0639 \u0643\u0645\u0631\u062c\u0639 \u0646\u0647\u0627\u0626\u064a.<\/p>\n<h3>\u0647\u0644 \u064a\u0645\u0643\u0646 \u0644\u0634\u0631\u0643\u0629 \u00ab\u062f\u0627\u0643\u0633\u064a\u0646 \u0625\u0646\u064a\u0631\u062c\u064a\u00bb \u062a\u0642\u062f\u064a\u0645 \u0627\u0644\u062f\u0639\u0645 \u0641\u064a \u0627\u062e\u062a\u064a\u0627\u0631 \u0627\u0644\u0646\u0638\u0627\u0645\u061f<\/h3>\n<p>\u0646\u0639\u0645. \u064a\u0631\u062c\u0649 \u062a\u0642\u062f\u064a\u0645 \u0642\u0627\u0626\u0645\u0629 \u0627\u0644\u0623\u062d\u0645\u0627\u0644\u060c \u0648\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0637\u0648\u0631 \u0648\u0627\u0644\u062c\u0647\u062f \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a\u060c \u0648\u0645\u062f\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629\u060c \u0648\u0627\u0644\u0647\u062f\u0641 \u0627\u0644\u0645\u062d\u062f\u062f \u0644\u0644\u062a\u0643\u0631\u0627\u0631\u060c \u0648\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0627\u062a\u0635\u0627\u0644\u060c \u0648\u0628\u064a\u0626\u0629 \u0627\u0644\u062a\u0631\u0643\u064a\u0628.<\/p>\n<h3>\u0637\u0644\u0628 \u062a\u0643\u0648\u064a\u0646 \u0645\u0634\u0631\u0648\u0639<\/h3>\n<p>\u064a\u0631\u062c\u0649 \u0625\u0631\u0633\u0627\u0644 \u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u062d\u0645\u0644\u060c \u0648\u0627\u0644\u0631\u0633\u0645 \u0627\u0644\u062a\u062e\u0637\u064a\u0637\u064a \u0623\u062d\u0627\u062f\u064a \u0627\u0644\u062e\u0637\u060c \u0648\u0648\u0642\u062a \u0627\u0644\u0646\u0633\u062e \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u060c \u0648\u0638\u0631\u0648\u0641 \u0627\u0644\u0645\u0648\u0642\u0639 \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0645\u062e\u0635\u0635 \u0644\u062c\u0647\u0627\u0632 UPS \u0623\u0648 \u0627\u0644\u0628\u0637\u0627\u0631\u064a\u0627\u062a.<\/p>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"9315\" data-end=\"9473\"><strong data-start=\"9315\" data-end=\"9349\">What is the DAXIN RM33 300kVA?<\/strong><br data-start=\"9349\" data-end=\"9352\" \/>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for large scalable critical-power applications.<\/p>\n<p data-start=\"9475\" data-end=\"9584\"><strong data-start=\"9475\" data-end=\"9508\">\u0645\u0627 \u0647\u064a \u0633\u0639\u0629 \u0627\u0644\u062e\u0632\u0627\u0646\u0629\u061f<\/strong><br data-start=\"9508\" data-end=\"9511\" \/>The RM33-300kVA reference configuration specifies 300kW cabinet capacity.<\/p>\n<p data-start=\"9586\" data-end=\"9721\"><strong data-start=\"9586\" data-end=\"9636\">\u0645\u0627 \u0647\u064a \u0642\u064a\u0645 \u062c\u0647\u062f \u0627\u0644\u062f\u062e\u0644 \u0648\u0627\u0644\u062e\u0631\u0648\u062c \u0627\u0644\u062a\u064a \u064a\u062f\u0639\u0645\u0647\u0627 \u0647\u0630\u0627 \u0627\u0644\u062c\u0647\u0627\u0632\u061f<\/strong><br data-start=\"9636\" data-end=\"9639\" \/>\u062a\u064f\u062f\u0631\u062c \u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a \u0627\u0644\u0645\u0631\u062c\u0639\u064a\u0629 \u0645\u062f\u062e\u0644\u0627\u062a \u0648\u0645\u062e\u0631\u062c\u0627\u062a \u062b\u0644\u0627\u062b\u064a\u0629 \u0627\u0644\u0623\u0637\u0648\u0627\u0631 \u0628\u0642\u062f\u0631\u0629 3 \u00d7 380\/400\/415 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f.<\/p>\n<p data-start=\"9723\" data-end=\"9867\"><strong data-start=\"9723\" data-end=\"9758\">What is the input power factor?<\/strong><br data-start=\"9758\" data-end=\"9761\" \/>The specification lists an input power factor of at least 0.99 at 100% load and at least 0.98 at 50% load.<\/p>\n<p data-start=\"9869\" data-end=\"10062\"><strong data-start=\"9869\" data-end=\"9914\">Does the RM33 support external batteries?<\/strong><br data-start=\"9914\" data-end=\"9917\" \/>Yes. The RM33-300kVA uses an external battery architecture, with final battery capacity and runtime engineered according to project requirements.<\/p>\n<p data-start=\"10064\" data-end=\"10216\"><strong data-start=\"10064\" data-end=\"10114\">Can the RM33-300kVA support remote monitoring?<\/strong><br data-start=\"10114\" data-end=\"10117\" \/>Yes. Optional SNMP network management is available for centralized power monitoring and management.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 300kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. With 300kW cabinet capacity, 380\/400\/415VAC three-phase operation, external battery configurations and optional SNMP monitoring, it supports large mission-critical power systems requiring flexible capacity and redundancy planning.<\/p>","protected":false},"featured_media":4961,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3010","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product\/3010","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/comments?post=3010"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/media\/4961"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/media?parent=3010"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product_brand?post=3010"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product_cat?post=3010"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/ar\/wp-json\/wp\/v2\/product_tag?post=3010"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}