الوصف
What Is the DAXIN 3H3 30kVA 3/3 Phase Online UPS?
The DAXIN 3H3 30kVA is a 30kVA/24kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.
Its 3/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.
The reference configuration supports 380/400/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.
Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.
- يدعم كل من المدخلات والمخرجات ثلاثية الطور الأحمال الحرجة الكبيرة.
- تدعم التحويلات عبر الإنترنت والتركيبات منخفضة التردد التطبيقات ذات المتطلبات الصعبة.
- تساهم وظائف العرض والإنذار والتجاوز والحماية في تسهيل صيانة الجهاز.
- تعتمد قدرات التشغيل المتوازي والتكرار على التكوين المحدد.
- تقوم إدارة هندسة المشاريع بالتحقق من السعة والجهد ومدة التشغيل وشروط التركيب.
المزايا الرئيسية
- 30kVA / 24kW Capacity: Designed for medium-capacity critical three-phase loads in industrial and infrastructure applications.
- 3/3 Phase Architecture: Three-phase input and three-phase output support critical three-phase electrical systems.
- Low-Frequency UPS Design: Intended for demanding industrial and infrastructure power-protection applications.
- Online Power Protection: Provides conditioned power for sensitive and mission-critical loads.
- 0ms Mains-to-Battery Transfer: Maintains output during utility-to-battery transition according to the reference specification.
- Configurable Battery System: Battery configuration and runtime can be engineered according to connected load and required backup duration.
- Monitoring and Protection: Display, alarm, protection and communication functions support system operation and maintenance.
- التكوين القائم على المشاريع: Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.
30kVA vs 40kVA UPS: Which Capacity Should You Choose?
The DAXIN 3H3 30kVA reference model is rated at 30kVA/24kW, while the 40kVA model provides a higher capacity for larger loads and additional expansion requirements.
The correct UPS should be selected according to the actual connected load in kW and kVA, power factor, startup or peak demand, required operating margin, future expansion and battery runtime.
Choose the capacity from calculated load requirements rather than equipment quantity alone. DAXIN ENERGY can review the load list and project requirements before final model selection.
What Does 3/3 Phase Mean in a UPS?
A 3/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.
This configuration is commonly used for critical three-phase loads in industrial facilities, data centers, telecom infrastructure, healthcare systems and transportation applications.
The DAXIN 3H3 30kVA uses this three-phase input and three-phase output architecture for applications requiring reliable 30kVA-class critical power protection.
معلومات عن المنتج والمراجع الفنية

التطبيقات النموذجية
- Industrial automation and manufacturing systems
- مراكز البيانات ومنشآت الخوادم
- البنية التحتية للاتصالات السلكية واللاسلكية
- Power and utility systems
- Hospitals and healthcare equipment
- Transportation and traffic-control infrastructure
- Commercial and public facilities
- Other critical three-phase electrical loads
How to Select a 30kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, startup or peak demand, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
For a 3/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communication interfaces and installation conditions for project configuration.
الأسئلة الشائعة
هل يمكن تخصيص هذا المنتج لمشروع معين؟
نعم. يمكن مراجعة التكوين الكهربائي، ومدة تشغيل البطارية، وأنظمة الاتصالات، ونظام التجاوز، وترتيب الخزانات، وملحقات المشروع، وفقًا لمتطلبات الموقع.
هل يتم تطبيق جميع التصنيفات الفنية على السلسلة بأكملها؟
لا. تختلف القيم التصنيفية والوظائف باختلاف الطراز والتكوين. يرجى الاعتماد على ورقة المواصفات الفنية الخاصة بالمشروع كمرجع نهائي.
هل يمكن لشركة «داكسين إنيرجي» تقديم الدعم في اختيار النظام؟
نعم. يرجى تقديم قائمة الأحمال، وبيانات الطور والجهد الكهربائي، ومدة التشغيل المطلوبة، والهدف المحدد للتكرار، ومتطلبات الاتصال، وبيئة التركيب.
طلب تكوين مشروع
يرجى إرسال بيانات الحمل، والرسم التخطيطي أحادي الخط، ووقت النسخ الاحتياطي المطلوب، وظروف الموقع للحصول على عرض مخصص لجهاز UPS أو البطاريات.
What is the rated capacity of the DAXIN 3H3 30kVA?
The reference model is rated at 30kVA / 24kW.
What does 3/3 phase mean?
It means the UPS uses three-phase input and provides three-phase output.
What is the mains-to-battery transfer time?
The reference specification lists 0ms mains-to-battery transfer.
What output voltage does the UPS support?
The reference configuration supports 380/400/415VAC three-phase output.
Should I choose a 30kVA or 40kVA UPS?
Select the capacity according to actual load in kW and kVA, power factor, peak demand, required operating margin, future expansion and backup-time requirements.
Does the 30kVA UPS support parallel redundancy?
Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification before system design.









المراجعات
لا توجد مراجعات بعد.